Commit Graph

183 Commits

Author SHA1 Message Date
Jon Evans c530bdb5a1 Rename GetSelectMenuText to GetItemDescription
This descriptive text is used for many more things than
just the select menu these days.
2023-01-11 22:27:44 -05:00
Wayne Stambaugh d99e09014b Rename SYMBOL_INSTANCE_REFERENCE to SCH_SYMBOL_INSTANCE. 2023-01-04 15:39:50 -05:00
Jeff Young 0b50e7fa37 A wee little hack for intersheet refs in legacy files.
Fixes https://gitlab.com/kicad/code/kicad/issues/13108
2022-12-27 18:46:58 +00:00
Wayne Stambaugh 78e2f0fd4d Sheet instance handling improvements. 2022-12-26 08:30:03 -05:00
Jeff Young 6f44468385 Fix more lifetime issues in simulator tuning.
Fixes https://gitlab.com/kicad/code/kicad/issues/13257
2022-12-23 22:03:24 +00:00
Jeff Young f75d18c7c8 Slight improvement to schematic editor title bar.
Also improves some other clients of PathHumanReadable(), such as the
set page number dialog.
2022-12-12 12:54:34 +00:00
Jeff Young b9287968d6 Update symbol default prefixes after updating instance data.
Also moves the sim model fixups after the instance data updating as
it uses the prefixes.
2022-12-07 01:34:56 +00:00
Jeff Young 38906397d2 Move V6->V7 sim model migration from sheets to screens.
Also moves passive RLC inference out from migration to just-in-time
creation for the simulator or netlisting.

Also fixes a version guard mismatch because the spice migration was
done inside UpdateSymbolInstances (which has its own version guard).

Also changed UpdateSymbolInstances to UpdateSymbolInstanceData so
someone else in the future doesn't think it's a general-purpose symbol
instance updater.
2022-12-06 16:01:18 +00:00
jean-pierre charras 6b9c82c975 eeschema: fix a crash when converting a old .sch file containing global labels. 2022-12-04 21:06:16 +01:00
Jeff Young f9b3f14dfa Bring intersheet refs in line with schematic setting when changing sheets.
Fixes https://gitlab.com/kicad/code/kicad/issues/13061
2022-12-04 11:51:44 +00:00
Wayne Stambaugh 0a62c17040 Remove schematic symbol value and footprint field instance data.
https://gitlab.com/kicad/code/kicad/-/issues/12933
2022-11-30 11:47:13 -05:00
Mikolaj Wielgus a65b35107d Sim: Make Sim.Pins have key-value pairs instead of a sequence
Moreover, upgrade models on schematic load instead of on model load
2022-11-25 05:38:21 +01:00
Wayne Stambaugh 4a27d856f7 Move schematic sheet instance information into file sheet definition.
This will make it possible to maintain sheet instance information when
copying and pasting from any sheet other that the root sheet of a
project.

Setting and getting sheet page numbers must now be performed using a
sheet path.  This was done to ensure that the instance paths were not
getting changed unexpectedly from different code paths.
2022-11-22 16:45:38 -05:00
Mikolaj Wielgus 6969362813 Sim Model Editor: Don't provide library-only models as builtins 2022-11-20 22:07:39 +01:00
Jeff Young 2919490e92 Use hash (not page no) to determine when we've found the current sheet.
Also enforces strict ordering in another page number sorter, although
this has nothing to do with the bug below.

Fixes https://gitlab.com/kicad/code/kicad/issues/12043
2022-11-20 13:12:44 +00:00
Mikolaj Wielgus e7c43ca20a Sim: Remove inference from Reference and Value 2022-11-18 08:39:15 +01:00
Marek Roszko 6ce714d537 Use wxCHECK instead of wxCHECK2 2022-10-15 11:25:15 -04:00
Marek Roszko ce2d091588 wxCHECK2 needs an actual "op", in this case return 2022-10-14 21:01:49 -04:00
Wayne Stambaugh a11c40197f Expunge default symbol instance from schematic file format.
Now that importing hierarchical sheets "properly" imports instance data,
the default symbol instance setting doesn't have any meaning.
2022-10-04 15:42:41 -04:00
Wayne Stambaugh 2b387ae9c3 Move schematic symbol instance data back into symbol definition.
This change reverts the storage of all symbol instance data in the root
schematic.  This was done because it's not possible to reuse instance
data when importing from sub-sheets.

There has been a fundamental change in how sheet paths are store in the
instance data.  The root schematic UUID is always used when saving the
instance data.  To prevent file churn, the virtual root sheet UUID is set
to the root schematic UUID when loading the project.  This provides a way
to determine the project that stored the instance data.  All uses of paths
without root sheet have been expunged from the code.

The sheet instance data is still saved only in the root sheet for the
time being.  New sheet instances will be automatically assigned an page
number based on the incremental virtual sheet page number.  Sheet page
numbers will not be imported.

Added project name to instance data to improve the readability of the
schematic file format.  It also creates an opportunity to remove orphaned
instance data by project name rather than cryptic UUIDs.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/12472
2022-10-02 15:06:42 -04:00
Wayne Stambaugh 979b4a4eb7 Revert "Move schematic symbol instance data back into symbol definition."
This reverts commit 7984e114db.
2022-09-29 15:33:23 -04:00
Wayne Stambaugh a60ed99510 Revert "Add project name to symbol instance data."
This reverts commit 4b276b339a.
2022-09-29 15:33:23 -04:00
Wayne Stambaugh 4b276b339a Add project name to symbol instance data.
This improves the readability of the schematic file format and creates
an opportunity to remove orphaned instance data by project name rather
than cryptic UUIDs.
2022-09-29 17:47:57 +00:00
Wayne Stambaugh 7984e114db Move schematic symbol instance data back into symbol definition.
This change reverts the storage of all symbol instance data in the root
schematic.  This was done because it's not possible to reuse instance
data when importing from sub-sheets.

There has been a fundamental change in how sheet paths are store in the
instance data.  The root schematic UUID is always used when saving the
instance data.  To prevent file churn, the virtual root sheet UUID is set
to the root schematic UUID when loading the project.  This provides a way
to determine the project that stored the instance data.  All uses of paths
without root sheet have been expunged from the code.

The sheet instance data is still saved only in the root sheet for the
time being.  New sheet instances will be automatically assigned an page
number based on the incremental virtual sheet page number.  Sheet page
numbers will not be imported.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/12472
2022-09-29 17:47:57 +00:00
Alex 58b03b0a1c Small optimizations. 2022-09-22 17:22:04 +00:00
Jeff Young 64a6fc0fd4 Push UNITS_PROVIDER down into a low-level mixin.
This allows us to also construct cheap UNIT_PROVIDERs for specific
tasks when necessary.
2022-09-19 17:10:59 +01:00
Mikolaj Wielgus 4ae2225b6d Sim: Replace all wxStrings with std::strings in SIM_VALUE 2022-09-16 06:11:14 +02:00
Alex 3a76d42630 Cross-probing/selection for multiple items (PCB -> SCH)
Fixes https://gitlab.com/kicad/code/kicad/issues/10469
2022-08-22 19:33:39 +00:00
Jeff Young 6f49b57f9b Cleanup & performance enhancements. 2022-08-01 13:09:51 +01:00
jean-pierre charras ee1d458af0 Eeschema: fix crash in SCH_SHEET_LIST::MigrateSimModelNameFields() for SCH_TXTBOX items.
Due to a typo, if a SCH_TXTBOX is in a scheet, it crashes eeschema.
2022-07-30 15:57:59 +02:00
Mikolaj Wielgus 7cf5138c63 Sim: Bugfixes, mostly for MS Windows compilation errors
Unfortunately, Windows headers define a lot of macros for common words,
so we had to rename some enums to not collide.

We also fix some of the many bugs related to the new simulation
architecture and the Spice Model Editor dialog.
2022-07-30 02:25:34 +00:00
Mike Williams bf550afa8c Annotation: use full hierarchy for sheet based numbering on paste 2022-07-25 18:44:55 +00:00
Jeff Young d24e6c3408 Auto-annotate (and then don't re-annotate) power symbols.
Fixes https://gitlab.com/kicad/code/kicad/issues/11942
2022-07-11 21:46:01 -06:00
Alex aaf99eb0cc Performance optimizations. 2022-07-11 21:25:12 +00:00
Seth Hillbrand 939313088e Units are stored in the instance data
At the moment, units are stored in the instance data, so when loading
the file, all symbols will have bbox for the first unit.  After calling
`UpdateUnit()`, we need to recache the rtree bounding boxes to get
correct hit tests

Fixes https://gitlab.com/kicad/code/kicad/issues/11681
2022-06-30 14:59:17 -07:00
Jeff Young 52eb210aa8 Initialize virtual page no. to something more reasonable.
Fixes https://gitlab.com/kicad/code/kicad/issues/11295
2022-04-24 19:46:57 +01:00
Wayne Stambaugh 239f0214ac Eeschema: add support for default schematic symbol instance data.
Prior to fixing the schematic file change churn do to instance data
changing to the last selected sheet instance, the symbol instance data
was set rather than empty.  This change allows for users to set the
default instance data which is used for every new instance of the
schematic.

ADDED: Default schematic symbol instance data (unit and reference, value,
       and footprint fields) can be set to be used as the default settings
       for all new instances of the schematic.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/11113
2022-04-09 07:49:36 -04:00
Jeff Young c6a8100d46 Schematic and symbol text boxes.
Also fixes some plot bugs with arcs.

Also moves polygonization of arcs (when required) in plotting code
from 5 degrees to calculated based on ARC_HIGH_DEF.

Fixes https://gitlab.com/kicad/code/kicad/issues/5017
2022-01-28 21:38:15 +00:00
Seth Hillbrand be5bb8c4bd Enforce strictly weak ordering in sheets
This ensures that irreflexivity is given in sort ordering.  This may
have been triggering issues in MacOS when adding sheets

Fixes https://gitlab.com/kicad/code/kicad/issues/10557

(cherry picked from commit a1615cce7e)
2022-01-24 10:41:21 -08:00
Roberto Fernandez Bautista 2d3624a016 Rename ComparePageNumAndName -> ComparePageNum 2022-01-02 23:20:17 +00:00
Roberto Fernandez Bautista a0d708e04d Use virtual page number when real page numbers are blank
Fixes https://gitlab.com/kicad/code/kicad/-/issues/10158
2022-01-01 18:36:56 +00:00
Marek Roszko c4c56de708 Neurotically update position wxPoint usages 2022-01-01 11:55:51 -05:00
Wayne Stambaugh b7af66e3f9 Eeschema: fix broken page numbers when renaming a sheet file name.
Always use full sheet paths when storing sheet instances.  Partial sheet
paths cannot be full resolved resulting in lost page numbers when renaming
sheet file name.

Fixes #9782
2021-12-09 12:56:03 +00:00
Wayne Stambaugh a03e6e4926 Revert "Eeschema: fix broken page numbers when renaming a sheet file name."
This reverts commit a468a79948.
2021-12-06 07:47:18 -05:00
Wayne Stambaugh a468a79948 Eeschema: fix broken page numbers when renaming a sheet file name.
Remove duplicate instance data saved in both root SCH_SCREEN and SCH_SHEET
objects that was causing them to be out of sync.  All sheet instance data
is stored in the SCH_SHEET object itself and rebuilt on the fly so it is
always current.

Remove Get/SetPageNumber from SCH_SHEET_PATH object so it doesn't obfuscate
where the actual sheet page number information exists.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/9782
2021-11-30 08:11:24 -05:00
luz paz 0446d35f0d Fix source comment/doc typos (follow-up)
Found via `codespell -q 3 -S *.po,./thirdparty -L aactual,acount,aline,alocation,alog,anormal,anumber,aother,apoints,aparent,aray,dout,einstance,modul,ot,overide,serie,te,,tesselate,tesselator,tht`
2021-07-13 10:48:17 +00:00
Jeff Young 4aa8318dc2 More error message regularization. 2021-06-27 14:24:02 +01:00
Wayne Stambaugh ff099453c8 Rename class_library.[h|cpp] to symbol_library.[h|cpp]. 2021-06-15 09:24:55 -04:00
Wayne Stambaugh ee3eac325d Expunge the use of the word part from Eeschema code. 2021-06-15 08:32:11 -04:00
Wayne Stambaugh 71c183d7bb Rename LIB_PART to LIB_SYMBOL. 2021-06-14 07:11:17 -04:00