Also moves passive RLC inference out from migration to just-in-time
creation for the simulator or netlisting.
Also fixes a version guard mismatch because the spice migration was
done inside UpdateSymbolInstances (which has its own version guard).
Also changed UpdateSymbolInstances to UpdateSymbolInstanceData so
someone else in the future doesn't think it's a general-purpose symbol
instance updater.
This change reverts the storage of all symbol instance data in the root
schematic. This was done because it's not possible to reuse instance
data when importing from sub-sheets.
There has been a fundamental change in how sheet paths are store in the
instance data. The root schematic UUID is always used when saving the
instance data. To prevent file churn, the virtual root sheet UUID is set
to the root schematic UUID when loading the project. This provides a way
to determine the project that stored the instance data. All uses of paths
without root sheet have been expunged from the code.
The sheet instance data is still saved only in the root sheet for the
time being. New sheet instances will be automatically assigned an page
number based on the incremental virtual sheet page number. Sheet page
numbers will not be imported.
Added project name to instance data to improve the readability of the
schematic file format. It also creates an opportunity to remove orphaned
instance data by project name rather than cryptic UUIDs.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/12472
This improves the readability of the schematic file format and creates
an opportunity to remove orphaned instance data by project name rather
than cryptic UUIDs.
This change reverts the storage of all symbol instance data in the root
schematic. This was done because it's not possible to reuse instance
data when importing from sub-sheets.
There has been a fundamental change in how sheet paths are store in the
instance data. The root schematic UUID is always used when saving the
instance data. To prevent file churn, the virtual root sheet UUID is set
to the root schematic UUID when loading the project. This provides a way
to determine the project that stored the instance data. All uses of paths
without root sheet have been expunged from the code.
The sheet instance data is still saved only in the root sheet for the
time being. New sheet instances will be automatically assigned an page
number based on the incremental virtual sheet page number. Sheet page
numbers will not be imported.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/12472
There was also a logic bug when the selected schematic was in a different
path than the current project and was already part of the current project.
The symbol library table reconciliation code was still run which was wrong.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11075
Found via `codespell -q 3 -S *.po,./thirdparty -L aactual,acount,aline,alocation,alog,anormal,anumber,aother,apoints,aparent,aray,dout,einstance,modul,ot,overide,serie,te,,tesselate,tesselator,tht`
Differentiates better between the EDA_ITEM IsModified(), referring to
items themselves changing and the EDA_SCREEN IsContentModified(),
referring to whether we have made any unsaved changes.
wx/wx.h includes all wxWidgets .h files, and sometimes creates collision
names in #define between kicad and windows headers
Moreover, blindly including a lot of useless files is compil time consuming
Using wxFileName::GetPath( wxPATH_WITH_SEPARATOR ) does not include the
drive specifier (A:, B:, C:, etc.) on windows which fails the comparison
with the project path 100% of the time. wxFileName::GetPathWithSep()
solves the issue nicely.
Fixes https://gitlab.com/kicad/code/kicad/issues/5077
Set up a new lineage for SCH_ITEMS to get back to the SCHEMATIC
they live on: Items will all be parented to the SCH_SCREEN that
they are added to, and each SCH_SCREEN will point back to the
SCHEMATIC that it is part of. Note that this hierarchy is not
the same as the actual schematic hierarchy, which continues to
be managed through SCH_SHEETs and SCH_SHEET_PATHS.