The accelerator strings really shouldn't be part of the translation,
and some translations have cause the accelerator keys to be incorrectly
handled. It is simpler to make it separate and just join them to the
translated string.
Make all accelerator modifiers use lowercased Ctrl instead of CTRL
to be the same as the other modifiers.
Fixes https://gitlab.com/kicad/code/kicad/issues/5992
These objects can now be used in advanced DRC rules and
not just for keeping things out. Also remove the restriction
that at least one of the "basic" keepout rules must be set,
so that these areas can be used for more advanced rules.
ADDED new rectangle graphics tool for PCBNew and Footprint Editor.
Also adds rectangle tool to both Footprint Editor and PCBNew Place
menus.
The Aux Origin tool can come back once we have multi-select toobar
buttons.
Also collapses an unnecessary level out of the auxOrigin and gridOrigin
settings.
Fixes https://gitlab.com/kicad/code/kicad/issues/2246
CHANGED: Settings are now stored in versioned sub-directories
ADDED: First-run dialog for migrating settings from a previous version
CHANGED: Settings are now stored as JSON files instead of wxConfig-style INI files
CHANGED: Color settings are now all stored in a separate settings file
CHANGED: The symbol editor and footprint editor now have their own settings files
CHANGED: Color settings are no longer exposed through BOARD object
CHANGED: Page layout editor now uses Eeschema's color scheme
Settings are now managed through a central SETTINGS_MANAGER held by PGM_BASE.
Existing settings will be migrated from the wxConfig format on first run of each application.
Per-application settings are now stored in one class for each application.
Create an IsContentModified() function in each frame
that provides if the content has been modified, and
use that instead of always copying the checks.
The pointer passing for display options is deprecated. This removes the
excess casting as the EDA_FRAME didn't need the base call with no value.
All requests for display options are now returned const and are updated
with a Set() routine after modification.
In Gerbview, this resolves an issue where the display options were not
stored because it was receiving the NULL from EDA_FRAME.
* Push a function into CONDITIONAL_MENU that adds the item
* Modify the tooltip for close and exit items to have the
program name
Fixes: lp:1835454
* https://bugs.launchpad.net/kicad/+bug/1835454
In singletop mode, all frames show the "Quit" option in the file menu
and will quit on Ctrl-Q. When launched from the main KiCad interface,
sub-programs show the "Close" option instead and will close with Ctrl-W.
In this mode, Ctrl-Q will instruct the main program to exit.
Fixes: lp:1779938
* https://bugs.launchpad.net/kicad/+bug/1779938