If a schematic contains two symbols with the same name from different
libraries, the cache will contain the last symbol saved with that name.
Prepend the library nickname with the original schematic symbol library
nickname when saving the cache library to prevent name collisions.
Check the if the schematic being loaded has been remapped (no symbol
library table nicknames defined) and remap accordingly.
Fix issues when resolving the library symbol links in the schematic
symbols.
Add cache library fallback when resolving symbols that cannot be
remapped.
Add remap complete message to remap dialog.
Add HasLibrary() helper to LIB_TABLE_BASE.
Fix issues when loading library symbols using symbol library table.
Add hashing function to symbol library table.
Improve the symbol panel message to warn user when cache library is
used to resolve symbol.
This is more a workaround than a fix.
The crash was due to the fact the library cache is modified on the disk with the saving process.
Fixes: lp:1702707
https://bugs.launchpad.net/kicad/+bug/1702707
For some reason, the schematic symbol library link was being regenerated
every time the schematic was redrawn in SCH_SCREEN::Draw(). Remove the
re-link call from the Draw() and Plot() functions.
Add function the SCH_SCREENS to update the links in all of the schematic
sheets.
Update all schematic sheet symbol library links whenever the symbol
library list is modified or any library in the library list is modified.
That should cover all cases where the symbol library links could be
broken.
Refresh schematic window after applying library changes to update any
possible symbol changes.
Add KIWAY message to update the schematic when symbol library changes
could change the schematic. The KIWAY mail was used because the schematic
frame is not a parent of the symbol library editor so wxEvents cannot be
used.
PROPERTIES object has been recreated every time it was needed, using
two fields in PART_LIB class. Now the buffering & caching settings are
stored directly in a PROPERTIES object.
Check for existence of cache library when before attempting to rebuild
the cache. Create a new cache library object if no cache library was
loaded.
Add missing buffering and cache properties to LIB_PART::FindAlias() to
prevent the plugin from reloading the cache library that may not exist.
Add method to find library by full path and file name.
Revert the check for a symbol in the cache library remove from last
patch.
Add checks for plugin cache file name validity and existence of a the
file before attempting to verify the file modification time to prevent
wxWidgets from raising an assertion in debug builds.
Clear modified flag when saving buffered and/or cached library.
Use LIB_ID instead of wxString for storing the library symbol information
in the schematic symbol in preparation for the upcoming symbol library table
implementation.
Change the FindLibAlias and FindLibPart functions in the PART_LIBS object
instead of wxString. Please note that only the library ID name is used to
search the list of libraries. The library nickname is ignored. Once the
symbol library table is implemented and full LIB_IDs are defined, the
library search code will no longer be used and will only be kept to load
older schematics that have not been converted.
Move SCH_LEGACY_PLUGIN_CACHE definition so that the legacy plugin knows
how to properly delete the cache object.
Add SCH_PLUGIN object to PART_LIB object.
Convert all PART_LIB I/O to use SCH_PLUGIN.
Remove library caching from PART_LIB and use caching provided by SCH_PLUGIN.
Add support to use PROPERTIES for buffering and document file write control
instead of adding code the SCH_PLUGIN object in the SCH_LEGACY_PLUGIN that
will not be required when the new file formats are implemented.
Add buffering to SCH_LEGACY_PLUGIN to prevent cache from writing file on
every change to library. This is to prevent the cache library from being
written every time a new symbol is added.
Add option to not save library document file when saving library. This is
primarily used by the cache library write code.
Move symbol library write code out of LIB_PART and into SCH_LEGACY_PLUGIN.
Add exception handling where LIB_PART caught the exception and returned
an error status.
Remove KICAD_SCH_IO_MANAGER build option as it is no longer optional.
Replace LIB_PART::Conflicts() with an external test to for alias name
conflicts. This was only use in one place so don't clutter the library
API.
Change LIB_PART::AddPart() return type from bool to void since it's not
checked by any callers and differs from the equivalent schematic I/O
plugin function.
Select the first library in the list and the first symbol in the first
library if they exist the first time the symbol viewer is opened.
Prevent clicking on the next or previous toolbar buttons from wrapping
past the end of the symbol list to mimic the behavior of the up and down
arrow key strokes.opens a select
library dialog.
Use incriminating or decrementing the current symbol selection when using
the next and previous symbol toolbar buttons rather looking up the next
symbol in the library. Just use the next or previous symbol name in the
list.
Replace the select library and select symbol from library list dialogs
which where redundant with the symbol search dialog used in place symbol
tool in the schematic editor. This gives the user type ahead search and
selects the library and symbol in one dialog.
Move updating toolbar buttons from the ReCreateHToolbar() function into
dedicated wxUpdateUIEvents.
Break Process_Special_Functions() into individual event handlers.
Remove PART_LIB::GetNextEntry() and PART_LIB::GetPreviousEntry() as they
are no longer required due to the changes to the symbol library viewer.
Purge wxT() macros from all modified source files.
Rename PART_LIB GetEntryNames() and RemoveEntry() to GetAliasNames() and
RemoveAlias() respectively for improved readability.
Rename PART_LIBS FindLibraryEntry() to FindLibraryAlias() improved
readability.
Remove commented out PART_LIBS::FindLibraryEntries().
Remove PART_LIB::GetFirstEntry() and update all effect code accordingly.
Remove unused PART_LIB::SetFileName() method.
Remove unused PART_LIBS::RemoveAllLibraries() method.
* Rename redundant function PART_LIB::GetEntry() to PART_LIB::GetAlias() which
is more descriptive and move the GetAlias() function which was nothing more
than a call to GetEntry().
* Write SCH_LEGACY_PLUGIN_CACHE object for handling the legacy symbol library
file format.
* Write legacy symbol library file parser.
* Write code to transfer cache to PART_LIB object so existing library save
code can be used for round trip testing. This is temporary until Eeschema
is updated to use the plugin for library management rather than PART_LIB.
* Add LIB_XXXX object helper functions where there was no way to set the member
variables of an object.
* Give the cache object friend status to some object where there are incredibly
byzantine ways of setting text in LIB_XXXX objects.
* Remove unused sort and make upper case options from PART_LIB::GetEntryNames()
and PART_LIB::GetEntryTypePowerNames() since they were never used anywhere in
the code. All comparisons are case sensitive and the array of names is always
sorted.
Libraries have been 100% case-sensitive for a while now; there is no longer a
need to keep this option around. This will change nothing except for any
stragglers still manually specifying this old option.
* Add code to test if any of the components in the schematic cache have been changed
in the component libraries.
* Prompt user to accept or reject components when changes are found.
* If the user chooses to use the components in the cache, create a new library with the old
components and add it to the beginning of the component library list so the schematic will
not be changed.
* Create dialogs to handle user feedback and status.
Previously, only the lib named "power" was used (and therefore power parts defined in other libs not shown).
Now, all power parts can be loaded from any library.
Also, when loading power parts from the chose component dialog or the lib viewer, libs and parts are filtered: only power parts and libs containing power parts are listed.
Hotkeys: move a few global strings in the files where ther are actually used (and make them local.) and code cleaning.
Fix a few other minor issues.
Schematic component properties dialog: add 2 helper buttons to manage the chip name (name of the corresponding part in lib)
- a browse button to chose an other chip name
- a test button, to know if the part exists. If not existing, list the parts found when searching using a case insensitive comparison.
However to be compatible with old versions of Eeschema, when a search in library fails, a case insensitive search is made.
Therefore, this version should be compatible with sch files created by previous Eeschema versions compiled with KICAD_KEEPCASE = OFF
*) When kicad.exe closes a project, close any open KIFACEs so that they cannot
get disassociated from their true PROJECT.
*) Allow loading eeschema library editor from kicad.exe
*) Allow loading pcbnew library editor from kicad.exe
*) Rename LIB_COMPONENT to LIB_PART.
*) Add class PART_LIBS, and PART_LIB.
*) Make PART_LIBS non-global, i.e. PROJECT specific.
*) Implement "data on demand" for PART_LIBS
*) Implement "data on demand" for schematic SEARCH_STACK.
*) Use RSTRINGs to retain eeschema editor's notion of last library and part being edited.
*) Get rid of library search on every SCH_COMPONENT::Draw() call, instead use
a weak pointer.
*) Remove all chdir() calls so projects don't need to be CWD.
*) Romove APPEND support from OpenProjectFiles().
*) Make OpenProjectFiles() robust, even for creating new projects.
*) Load EESCHEMA colors in the KIWAY::OnKiwayStart() rather in window open,
and save them in the .eeschema config file, not in the project file.
*) Fix bug with wxDir() while accessing protected dirs in kicad.exe
*) Consolidate template copying into PROJECT class, not in kicad.exe source.
*) Generally untangle eeschema, making its libraries not global but rather
held in the PROJECT.
The desire is to migrate designs *away from* case independence, and to create
designs which use literally (case specific) interpreted component names. But for
backwards compatibility, you may turn OFF this option if you really must.
(Remember that with KiCad using text data files, typically you would be better
off simply doctoring those files into a case literal state with a text editor
and move forward into the brave new world of case specificity. Also, BOM
generators may not work properly when you have this option turned OFF, the xml
export's referential integrity is broken on library part name. Hence the default
is ON now, as of 29-Jan-2014.
* Move the component library save file creation and write error dialogs
into the appropriate frame object.
* Change the save component library and document definitions take an
OUTPUTFORMATTER object instead of a file name.
* Change the component alias save document definition function to take
an OUTPUTFORMATTER object instead of a file handle.
* Move the hierarchical label connected test into the NETLIST_OBJECT class.
* ERC pin type strings can now be translated.
* Remove unused EDA_DRAW_PANEL attribute from all ERC test functions.
* Add get marker count method to SCH_SCREENS object.
* Redundant header removal.
* Lots of coding style policy fixes.
* Disable save library command when user does not have permission to write
the active library.
* Append the active library file name displayed in the title bar with read
only when the user does not have write permission.
* Test the selected folder permissions when user chooses the save library
as command.
* The obligatory coding style policy fixes.