- honor mirroring of fields attached to labels (all types)
- fix incorrect orientation of the graphic shape of SCH_DIRECTIVE_LABEL items
after mirroring the item.
Fixes#14758https://gitlab.com/kicad/code/kicad/issues/14758
Version 7 text alignment changed subtly for stroke fonts from version 6.
Additionally, the output has been different between screen and plotting,
leading to offset text in plotted output relative to the text shown on
screen.
This introduces a fudge factor in FONT::getLinePositions to correct the
offset in the plotting output relative to v6.
This also changes the SCH_PAINTER and PCB_PAINTER to correct the
relative offsets between GAL and PLOTTER classes. The source of these
offsets is atm unclear.
Fixes https://gitlab.com/kicad/code/kicad/issues/14755
SCH_CONNECTION objects are temporary and can become stale any time the
connectivity is updated. Keeping them around to reference later is a
bad idea. Even if the object pointer is still valid in an SCH_ITEM in
the undo/redo buffers, comparing the pointer against another pointer as
a test to see if they are the same connection is not valid. Saving the
connection name is safe and ensures the connection is the same even if
the pointers differ.
The propagation is currently (maybe not needed) limited to the global
name that is the source of the change. We also need to propagate the
global name that is changed in case the global is set in a tree leaf and
not the root
Fixes https://gitlab.com/kicad/code/kicad/issues/14657
A sheetpath is required to correctly resolve text variables.
Depending on currentSheet is rife with bugs.
There are many places where we do *not* want to be prepending
field names to the field values, such as netlisting,
building PDF hypertext menus, etc.
Also, Find/Replace needs to work on unresolved text, as
that's what we're going to display (and if replace nuked
your variable references you wouldn't be happy).
The netlist exporter was never updated to exclude symbols that are
tagged as power symbols. Only the legacy power symbol name prefix
('#') was used as the power symbol check. Power symbols no longer
require the '#' name prefix.
Needs to be static, so keep the reference from the associated symbol and
not the SCH_SYMBOL instance. Both will likely have the same prefix,
which is all we care about here
We're going to use the dataStore to update the symbol, so
if we store resolved values it will nuke any text variables
even if the field wasn't edited.
Not sure if the BOM generator has a separate resolve-variables
step or not. But it will need one as the code removed here
only worked for Values and Footprint fields anyway.
Fixes https://gitlab.com/kicad/code/kicad/issues/14423
This ensures that when bus elements or labels matching bus elements are
removed that the stale neighbor/parent references are similarly removed
Matching 7.0 commit 4cdf75dc72
The undo command has accreted a number of things over the years. This
prunes back the changes to the minimum required number and correctly
orders the actions
Fixes https://gitlab.com/kicad/code/kicad/issues/14661
Also simplifies the scoring algorithm so that it only
differentiates between exact-match, match-at-start and
any-match. The rest of the position-based matching
stuff is gone, as is the knowledge of the name vs the
keywords vs the description. All that is left to the
provider of the weighted search terms array.