Commit Graph

11 Commits

Author SHA1 Message Date
Seth Hillbrand 7d9222926a Connectivity: Correct alias-based bus resolution
Aliases in bus resolution were being resolved without a path, making
them effectively global nets.  This applies the corrected path to the
bus members and adds a QA to catch this error
2023-06-02 14:25:26 -07:00
Seth Hillbrand 57f0150a23 Ensure _changed_ netlist is propagated
The propagation is currently (maybe not needed) limited to the global
name that is the source of the change.  We also need to propagate the
global name that is changed in case the global is set in a tree leaf and
not the root

Fixes https://gitlab.com/kicad/code/kicad/issues/14657

(cherry picked from commit 6e4de18e15)
2023-05-09 12:13:30 -07:00
jean-pierre charras 2bbff64a12 Fix compatibility of QA golden files with 7.0x version 2023-04-13 08:01:32 +02:00
Seth Hillbrand 68dfcddbe9 Allow bus elements to connect
Previously, bus elements that were not instantiated as individual nets
could not connect to each other.  This caused issues for complex
schematics where busses needed to connect to other busses with elements
that resolved to the same net names.  Functionally, this means mixing
bus elements, which we will replace with first-class elements in version
8 but currently can only be accomplished either by using bus aliases and
  this patch or by individually instantiating each bus element as a
local label

Fixes https://gitlab.com/kicad/code/kicad/issues/14300

(cherry picked from commit 16b4ec3c7e)
2023-04-12 16:10:50 +02:00
Seth Hillbrand 39dcd0a352 Handle nested netclass assignments
Netclass directives should not be overriden, instead hold our error
checking for actually missing nets

Fixes https://gitlab.com/kicad/code/kicad/issues/14494

(cherry picked from commit 012737593b)
2023-04-06 17:38:42 -07:00
JamesJCode b82020722b Eeschema netlist output: Propagate NC across hierarchical schematics
Fixes #12580

Additionally does not export no_connect netlist annotation on pins
which are both connected to another pin and a NC item, unless all
connected pins are stacked at the symbol level.

Adds testing of pin types to netlist QA unit tests.

(cherry picked from commit 9dca70a773)
2023-03-06 16:22:25 -08:00
Seth Hillbrand fc86998bf6 Ensure duplicate pin names get unique nets
Same pin name != same net name unless the pins are explicitly connected

Also add pin number to all unconnected pads ensuring they have unique
nets

Fixes https://gitlab.com/kicad/code/kicad/issues/13236
2023-01-04 11:32:15 -08:00
Jeff Young 09c9bc3037 Fix net ordering in gold file. 2022-05-27 21:28:17 +01:00
Jeff Young e9e1878d96 Attempt to fix eeschema tests.
(Slashes in netnames must be escaped or else we think they're path
separators.)
2022-05-27 17:53:11 +01:00
Roberto Fernandez Bautista 55f22c526a Fix annotation of incomplete multi-unit symbols and re-annotation of duplicates
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11496
2022-05-26 09:23:36 +00:00
Sylwester Kocjan cfb8fbc644 qa: move eeschema data to appropriate directory 2022-03-30 11:13:23 +00:00