- Support unicode footprint names
- Set default footprint text size and thickness to match KLC
- Position Reference at the top, Value at the bottom of fp bounding box
The IPC-7351C rule (which may be IPC 7352 now), is 25%, or
0.25mm, whichever is smaller. Currently the default ratio is 25%, which
is incorrect for pads with shortest edges over 1mm.
This also means that the "25%" default is applied in one place:
previously sometimes the value came from the default set in PAD,
rather than the value set by this dialog. While the PAD default isn't
changed here, this dialog no longer relies on that value for its
behaviour.
If KiCad crashes or exits without deleting the lockfile, don't show the
warning message unless we are not the one who locked it or there are
other KiCad instances running locally.
This should catch 99% of the cases where the message is shown
incorrectly. There may be some corner cases where the lock file is
created on a network drive using two different machines with the same
name and same user but these cases should be (famous last words)
sufficiently rare as to not be observed in practice
- Writes expansion values to board design settings
- Imports footprint regions on Cu layers as pads
- Adds support for holes in non-Cu polygons in footprints
Previous test depended on which track was first. Re-saving the board
changed the track order, so there was no pad connected. It was still in
the connectivity database, just not at the first track
Default dialog to SPICE command.
Any of the three axis locks must lock the plotWindow Y axis (otherwise
locking Y2 but not Y1 doesn't preclude zooming).
Previous check only looked for the existence of a new (as of v6) flag
that controlled which strategy we took. Previous versions did not write
this flag and so will not hit the check. This works around a missing
version bump from when the feature was introduced.
- added option: display board body or just copper layers
(useful to set the 3D model position)
- fix a bug: do not use 3D viewer settings, and do not modify 3D viewer settings
KICAD_MANAGER_FRAME Ctor. Two advantages:
- it is built after the splash screen is dismissed.
- if there are issues when creating the PLUGIN_CONTENT_MANAGER, this is more
easy to debug