* Correct all user strings and comments for the correct capitalization of
application names according to JP. They are KiCad, Pcbnew, CvPcb,
Eeschema, and GerbView.
* Add a note the the user interface policy about the correct capitalization.
* All header files used to create the PCB common library now compile as
stand alone code. This prevents the need to define them in a specific
order to make source code compile properly. It should also now be
possible to relocate the source code to build the common PCB library
to a separate folder.
* Rename all member variables and methods that reference the cross hair
code in draw panel object from cursor to cross hair to eliminate confusion
between the two concepts.
* Rename cursor capture call backs in draw panel object to improve code
readability.
* Create helper class for turning off the cross hair while drawing.
* Remove redundant block clear code.
* Remove redundant mouse capture call back reset code when end capture
call back is called.
* Remove unused function definitions in base draw frame object.
* Lots of minor coding policy and doxygen comment fixes.
inches and mm, the industry is crazy enough to force us with mixed
design. For example I routinely use imperial units for track size and
clearance, but drilling is strictly a metric issue...
So I added a little parser to recognize a suffix specification in the
unit text boxes... so you can put in things like:
1in (1 inch)
1" (idem)
25th (25 thou)
25mi (25 mils, the same)
6mm (6 mm, obviously)
The rules are: spaces between the number and the unit are accepted, only
the first two letters are significant.
As a bonus, it also recognize the period (.) as a decimal point
substituting it with the correct locale character (there was a wishlist
for it, IIRC). Most useful for number pad fans :D
* Split out application specific command IDs to prevent unnecessary rebuilding.
* Eliminate duplicate menu and tool bar command IDs.
* Split component library editor and viewer definitions to separate header files.
* More component library and document file merge code.
* A bunch of minor string readability and consistency fixes.
================================================================================
+eeschema
* commiting my changes to allow multiple instances of a given schematic file within
a hierarchy:
** internally, m_currentScreen has been replaced with m_currentSheet,
which is a list or 'path' of screens. The path of screens is used to
generate
a series of timestamps, which is converted to flat component reference via
a look-up
table in the schematic files.
** this means that m_currentScreen is no longer used -- use GetScreen().
** GetScreen is virtual, as some of the dialogs keep around a WinEDA_BaseScreen
pointer.
** all sub-sheets in a given schematic must have different names to generate a
meaningful netlist.