Commit Graph

24 Commits

Author SHA1 Message Date
qu1ck 0c049eccc7 Fix a bunch of compiler warnings 2023-04-11 17:01:30 +00:00
Roberto Fernandez Bautista e8ead30baf WIP: CADSTAR Parts now shows up in library tables and is handled correctly (todo: read cadstar header) 2023-03-16 21:07:05 +01:00
Jon Evans ae6a2a6443 ADDED: Database libraries MVP
Allows placing parts from an external database that reference symbols from another loaded library.

Includes:
- nanodbc wrapper
- database schematic library plugin
- basic tests

Fixes https://gitlab.com/kicad/code/kicad/-/issues/7436
2022-08-26 10:51:13 -04:00
Wayne Stambaugh cb72da294a More NULL expunging. 2021-07-16 16:13:41 -04:00
Jeff Young 2ad69fc56b Move importers from wxLog to REPORTER.
Fixes https://gitlab.com/kicad/code/kicad/issues/6389
2021-03-31 22:54:30 +01:00
Michael Kavanagh c40483d18a Cleanup: Move KiCad files into plugins folder 2020-10-12 16:36:08 +00:00
Michael Kavanagh 1416280662 Cleanup: Move Eagle files into plugins folder 2020-10-05 14:19:07 +00:00
Roberto Fernandez Bautista 2d99703e28 CADSTAR Schematic Archive Importer: Load all Sheets and Hierarchical Blocks 2020-09-27 18:13:58 +01:00
Roberto Fernandez Bautista 721cba32d5 ADDED: CADSTAR Schematic Archive Importer
Initial commit to trigger the importer
2020-09-27 18:13:57 +01:00
Thomas Pointhuber a03fb7a9a8 Altium: Refactor and add initial structure for schematic importer
altium: move pcbnew/altium2kicadpcb_plugin -> pcbnew/plugins/altium

See: https://gitlab.com/kicad/code/kicad/-/issues/4412
2020-08-23 19:01:08 +00:00
Wayne Stambaugh b624c7090a Deprecate saving legacy schematic and symbol library file formats.
REMOVED: The ability to save schematics in the legacy file format.
2020-05-29 12:43:00 +00:00
Wayne Stambaugh 7183e9f97e Make the new schematic and symbol library file formats the default.
This is a very large and potentially disruptive change so this will be an
unusually long and detailed commit message.

The new file formats are now the default in both the schematic and symbol
library editors.  Existing symbol libraries will be saved in their current
format until new features are added to library symbols.  Once this happens,
both the legacy schematic and symbol file formats will be no longer be
savable and existing libraries will have to be converted.  Saving to the
legacy file formats is still available for round robin testing and should
not be used for normal editing.

When loading the legacy schematic file, it is imperative that the schematic
library symbols are rescued and/or remapped to valid library identifiers.
Otherwise, there will be no way to link to the original library symbol and
the user will be required manually set the library identifier.  The cached
symbol will be saved in the schematic file so the last library symbol in
the cache will still be used but there will be no way to update it from the
original library.

The next save after loading a legacy schematic file will be converted to
the s-expression file format.  Schematics with hierarchical sheets will
automatically have all sheet file name extensions changed to .kicad_sym
and saved to the new format as well.

Appending schematics requires that the schematic to append has already been
converted to the new file format.  This is required to ensure that library
symbols are guaranteed to be valid for the appended schematic.

The schematic symbol library symbol link resolution has been moved out of
the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the
symbol.  This was done to ensure that there is a single place where the
library symbol links get resolved rather than the dozen or so different
code paths that previously existed.  It also removes the necessity of the
SCH_COMPONENT object of requiring any knowledge of the symbol library table
and/or the cache library.

When opening an s-expression schematic, the legacy cache library is not
loaded so any library symbols not rescued cannot be loaded.  Broken library
symbol links will have to be manually resolved by adding the cache library
to the symbol library table and changing the links in the schematic symbol.

Now that the library symbols are embedded in the schematic file, the
SCH_SCREEN object maintains the list of library symbols for the schematic
automatically.  No external manipulation of this library cache should ever
occur.

ADDED: S-expression schematic and symbol library file formats.
2020-05-04 12:40:03 +00:00
Jeff Young c663965498 Fix some issues with sheet border color handling. 2020-04-05 16:17:04 +01:00
Wayne Stambaugh 7dc64f08b7 Eeschema: implement s-expression schematic file formatter.
Please note that the symbol cache is not embedded in the schematic file
to allow for round robin testing with the existing file format.  Once
the parser round robin testing is complete, the symbol cache will be
embedded in the schematic file.
2020-03-16 09:05:16 -04:00
Wayne Stambaugh 9d6f64da9a Implement symbol library s-expression parser.
This implements all existing symbol library object support and the ability
to save and load symbol library files between file formats for round robin
testing.
2020-03-03 08:06:23 -05:00
Wayne Stambaugh e1900161a7 Eeschema: implement new symbol library file s-expression formatter.
CHANGES: Symbol library file format has been converted to s-expressions.

Add support code for picking apart symbols at some future junction that
will allow full inheritance conversion of existing symbol libraries.  For
now, symbols arranged by unit and body style numbers are nested for round
robin testing of symbol libraries once the parser is complete.
2020-03-03 08:06:22 -05:00
Simon Richter a9ccf1161b Fix quotes in UI messages
This replaces all single and angle bracket quotes in UI messages with
double quotes, for consistency.

Sorry to all translators.
2017-12-15 07:33:07 -05:00
Wayne Stambaugh 8b2b1381c4 Fix symbol library table editor plugin type selection bug.
Remove the placeholders for the upcoming s-expression schematic and
symbol library file format plugin type.  The lack of a valid plugin
implementation was causing an undefined plugin type string in the
plugin type selection cell when new rows were added to the table.

Fixes lp:1733116

https://bugs.launchpad.net/kicad/+bug/1733116
2017-11-19 16:53:31 -05:00
Wayne Stambaugh 652b969193 GTK+ file dialog wildcard improvements.
The GTK+ file dialog is case sensitive however it does support regular
expressions.  Most of the file dialog wildcards are lower case so only
files with the lower case extensions will show up in the file dialog.
This code adds a method to convert file extensions of any case to the
appropriate (sch -> [sS][cC][hH]) regular expression on GTK+ builds so
all file extension case combinations will show up in the file dialog.

A note to developers: make sure to add a file extension when setting
when setting the default file argument.  If you do don't set an
extension, the GTK+ file dialog will happily append the regular
expression as the file extension which is surely not what you want.

There are still a few known places (mostly gerbview) where there are
some complex wildcard code that has not been converted.

Fixes lp:1720542

https://bugs.launchpad.net/kicad/+bug/1720542
2017-11-11 19:32:26 -05:00
Marvin Schmidt 69974b73db Remove some extra semicolons 2017-11-09 19:52:18 +01:00
Maciej Suminski d6383893a2 eeschema: Iterate through plugins when determining file format. 2017-10-20 08:38:38 +02:00
Alejandro García Montoro 2403f2b558 Adds necessary structure to implement and test Eagle schematich plugin 2017-10-20 08:38:37 +02:00
Wayne Stambaugh 98ad5096b0 Eeschema: add saving schematic files to schematic plugin.
* Add SCH_PLUGIN::Save() for current file format and code for saving all
  SCH_XXX objects.

* Add function to SCH_FIELD to get the position of the field in the component
  not the position added to the component position which is what GetPosition()
  does.  This was required because saving the component field expects position
  of the field sans the position of the component.

* Remove public members from BITMAP_BASE object and fix all associated
  code.

* Fix the never ending coding policy violations found making these changes.
2016-07-11 15:48:46 -04:00
Wayne Stambaugh 4ed346ea64 Eeschema: initial schematic I/O plugin.
* Factor out PROPERTIES object from the PCB plugin code and move it into
  common so it can be used by both the Pcbnew and Eeschema plugins.

* Add schematic I/O plugin manager for loading and saving schematic and
  component library files.

* Add initial attempt at a parser for current schematic file format.  This
  parser will be infinitely more strict than the current parser which is very
  forgiving in what it parses.

* Make minor changes to the base bitmap class to support the new parser.

* Add find root sheet support to sheet object to allow fetching the root
  sheet from any sheet in the stack.
2016-07-06 05:22:56 -04:00