It's tempting to say that we don't need to exclude filename chars
from symbols, but we might regret that decision down the road. Better
to just escape them.
Fixes https://gitlab.com/kicad/code/kicad/issues/8694
(Otherwise inheriting from the netclass or schematic doesn't work.)
Also fixes precedence order in GetPenWidth() for the two BUS_ENTRY
classes.
Fixes https://gitlab.com/kicad/code/kicad/issues/8601
1) Generalize SCH_ITEM owners (SCH_COMPONENT, SCH_SHEET, and now
SCH_GLOBALLABEL)
2) Generalize hypertext items
3) Use SCH_FIELD autoplace infrastructure for placing intersheet
references
4) Use textVar infrastructure for buildin intersheet references.
As an important side-effect this also fixes the undo issues with
intersheet refs.
CHANGED: In Schematic Setup->General->Formatting->Connections, added
pulldown for "Junction dot size" with values none, smallest, small
default, large, largest" Added support in "sch_painter.cpp" to not
paint junction when they have a diameter of "1" which is what "none"
sets as the diameter.
EDA_ITEM is a child of VIEW_ITEM, so a static_cast is not appropriate,
since in some cases it could be called with a non-EDA_ITEM argument.
This was triggering an ASAN heap-buffer-overflow in GerbView.
This way, when the user changes their color theme, any sheets
that did not have a specific color set will change with the theme.
Also add a button to clear color overrides from a sheet, because
any schematics that have been saved before this change will have
the colors set to something other than UNSPECIFIED.
ADDED Eeschema-specific netclass settings including wire and bus
thickness, color, and line style.
Netclasses override individual wire & bus colors and line styles.
If that proves an issue we might look at something more sophisticated
with inheritance.
Fixes https://gitlab.com/kicad/code/kicad/issues/4581
Remove extraneous use of FLAG0 from tracks cleaner (it was checked but
never set).
Fix issue in expand connections where two parts of it couldn't agree
on the same flag (BUSY vs SKIP_STRUCT), and where the second part was
clearing the flag instead of setting it.
Remove obsolete HIGHLIGHT infrastructure (we now use selection).
Remove extraneous use of BUSY flag in several places (it was never
set).
Add missing plot and print changes for the new bus entry properties.
ADDED: Junction properties diameter and color can now be edited.
Fixes: https://gitlab.com/kicad/code/kicad/issues/4593
Set up a new lineage for SCH_ITEMS to get back to the SCHEMATIC
they live on: Items will all be parented to the SCH_SCREEN that
they are added to, and each SCH_SCREEN will point back to the
SCHEMATIC that it is part of. Note that this hierarchy is not
the same as the actual schematic hierarchy, which continues to
be managed through SCH_SHEETs and SCH_SHEET_PATHS.