Make all EDA_TEXT data private and rename accessors to avoid function
name collisions in derived classes.
Overload EDA_TEXT's SetTextAngle() and SetEffects() in TEXTE_PCB.
Add support for preserving Reference text position, size, orientation
during a netlist import into a BOARD, as well as the one off footprint
update dialog.
It should help if (or when) the internal angle unit used in kicad will be changed from 0.1 degree (a relic of code written for PCs without fpu) to degree ( a more natural unit).
* Always hide footprint text when the layer that the text resides is disabled
in the layer manager. There is no longer a difference between the value and
reference text compared to other field text.
* The usual smattering of coding policy fixes and general code cleaning.
this option was possible only by modifying the way display options are managed.
before these changes, display options were a global DISPLAY_OPTIONS class instance.
Now each EDA_DRAW_FRAME(and derivated classes) includes its own DISPLAY_OPTIONS class instance.
As a consequence, some duplicate display option variables in these classes have been removed, because there were just duplicate variables of the DISPLAY_OPTIONS class instance.
* Make title capitalization consistant.
* Replace some instances of module with footprint.
* Use angle instead of orientation where appropriate.
* Remove abbreviations where it made sense.
* Coding policy fixes.
Handles % macro expansion in user texts inside pcb modules.
At the moment the following are available:
%% A plain %
%R Insert the reference
%V Insert the value
change also name TEXTE_MODULE::RotateWithModule to TEXTE_MODULE::RotateTransformWithModule for same reason.
Pcbnew: fix Bug #1374484 (text changes position when module is flipped and rotated). Fix also some bugs in modedit, in block commands.
Also do not allow copper layers, solder paste and solder mask: put Ref or Value on these layers has no sense, and can create serious issues on the board.
The members SetIgnoreMTextsOnCopper, SetIgnoreMTextsOnCmp,
SetIgnoreModulesOnCu, SetIgnoreModulesOnCmp in the collector guide are
renamed to the clearer SetIgnoreMTextsOnBack, SetIgnoreMTextsOnFront,
SetIgnoreModulesOnBack, SetIgnoreModulesOnFront
Modified the collector and drawing behaviour for text in modules as
discussed in the mailing list.
* Now module text on layers different than Silk should work! *
Still need UI support for setting the layer in the module editor.
- Removed the friends MODULE and FOOTPRINT_EDIT_FRAME from TEXTE_MODULE
(as in the @todo comment)
- Refactored the Rotate/Flip/Mirror for text in modules into the
TEXTE_MODULE class itself (members RotateWithModule, FlipWithModule,
MirrorWithModule)
- New behaviour in coloring text on screen: reference and value still
take the color from the MOD_TEXT_FR_VISIBLE and MOD_TEXT_BK_VISIBLE
visibles; other text takes the color of the layer containing it
(except when hidden, obviously) but still get its visibility
controlled by those visibles (probably the most intuitive and useful
behaviour)
- Still need to decide: should text on a layer be hidden when the layer
is? Probably yes (still to be implemented);
- Some comment fixed and many cast converted to static_cast
2) Change from legacy Cu stack to counting down from top=(F_Cu or 0).
The old Cu stack required knowing the count of Cu layers to make
sense of the layer number when converting to many exported file types.
The new Cu stack is more commonly used, although ours still gives
B_Cu a fixed number.
3) Introduce class LSET and enum LAYER_ID.
4) Change *.kicad_pcb file format version to 4 from 3.
5) Change fixed names Inner1_Cu-Inner14_Cu to In1_Cu-In30_Cu and their
meanings are typically flipped.
6) Moved the #define LAYER_N_* stuff into legacy_plugin.cpp where they
can die a quiet death, and switch to enum LAYER_ID symbols throughout.
7) Removed the LEGACY_PLUGIN::Save() and FootprintSave() functions.
You will need to convert to the format immediately, *.kicad_pcb and
*.kicad_mod (=pretty) since legacy format was never going to know
about 32 Cu layers and additional technical layers and the reversed Cu
stack.
Pcbnew: Code cleaning and bug fix in autoplace functions
Dialog exchange footprints has now a separate button to update the .cmp file, only on request.
Eagle plugin: filter and replace not allowed chars in FPID(-':' and '/') by _ or -, if they are used in Eagle footprint names (otherwise, boards converted and saved under kicad_pcb format are not readable by Pcbnew).
The plan goes like this:
- eeschema still uses int in decidegrees
- all the other things internally use double in decidegrees (or radians
in temporaries)
- in pcbnew UI the unit is *still* int in decidegrees
The idea is to have better precision everywhere while keeping the user with int i
angles. Hopefully, if a fractional angle doesn't come in from the outside, everything
should *look* like an integer angle (unless I forgot something and it broke)
When the time comes, simply updating the UI for allowing doubles from the user should
be enough to get arbitrary angles in pcbnew.
- Removed spurious int casts (these are truncated anyway and will break
doubles)
- Applied the Distance, GetLineLength, EuclideanNorm, DEG2RAD, RAD2DEG
ArcTangente and NORMALIZE* functions where possible
- ArcTangente now returns double and handles the 0,0 case like atan2, so
it's no longer necessary to check for it before calling
- Small functions in trigo moved as inline