Previous use of instance was as an "override" of the default value.
This has changed to be used as the primary storage location for all
values. This means that we cannot clear the instance data when setting
a new value for all instances, instead we have to change the instance
data and the default value is superfluous
Fixes https://gitlab.com/kicad/code/kicad/issues/11439
Prior to fixing the schematic file change churn do to instance data
changing to the last selected sheet instance, the symbol instance data
was set rather than empty. This change allows for users to set the
default instance data which is used for every new instance of the
schematic.
ADDED: Default schematic symbol instance data (unit and reference, value,
and footprint fields) can be set to be used as the default settings
for all new instances of the schematic.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11113
ADDED arc, circle and rectangle shapes for schematic. Shapes support
line styles and fill colors.
CHANGED sheet background color in Edit Text & Graphics Properties to
fill color (and it now affects shapes).
Pushed STROKE_PARAMS down into common and moved all shapes to using it
for stroke descriptions.
Grid-based accuracy doesn't need to be any larger than 1/2 the
diagonal as we'll snap to one side or the other. And symbols don't
need as much slop as other items since there's plenty of "meat" on
them.
Fixes https://gitlab.com/kicad/code/kicad/issues/9805
Text has a fairly big bounding box to account for descenders, overbars,
etc., but it makes it feel too sloppy for hittesting. This change
allows selection disambiguation to look at the actual strokes of the
text when deciding what's "closest".
Fixes https://gitlab.com/kicad/code/kicad/issues/9506
They don't define a KiCad string class, so the header file name was
somewhat misleading. But the fact that they didn't match definitely
made coding more difficult.
It's tempting to say that we don't need to exclude filename chars
from symbols, but we might regret that decision down the road. Better
to just escape them.
Fixes https://gitlab.com/kicad/code/kicad/issues/8694
Given a symbol U12A, some parts of the code were assuming the prefix was
'U' while others were assuming 'U12'. Further complication arose when
there were '?' in the library version.
Fixes https://gitlab.com/kicad/code/kicad/issues/8223
1) Don't reset value when name changes
2) Don't fire events when initialising dialog
3) Make sure when symbol is saved back to schematic that only current
instance has its ref updated, but that all instances have their other
fields updated.
4) When saving symbol back to board always use the fields from the
editor and not the (alias-specific) ones from the library.
Fixes https://gitlab.com/kicad/code/kicad/issues/8159