We need to ensure that the appended sheet does not already exist in the
parent hierarchy. We do this for new sheets but need to check for
existing ones as well.
Fixes#3806 | https://gitlab.com/kicad/code/kicad/issues/3806
This moves EESchema DLIST structures to rtree. These changes are more
fundamental than the pcbnew changes from 9163ac543888c01d11d1877d7c1
and 961b22d60 as eeschema operations were more dependent on passing
drawing list references around with SCH_ITEM* objects.
"INPUT" declaration in sch_text.h generate *a lot of* compil warnings.
So it is replaced by PS_INPUT.
For consistency, others member of enum class PINSHEETLABEL_SHAPE are also renamed.
For legacy reasons, it stored left and right "spin" as flipped integers in the file format.
But the code handled the flip in multiple locations rather than just doing it on file io.
This change unifies the internal code and does the mapping in the file I/O.
Add missing check for root sheet when searching sheet hierarchies for
already loaded schematics. This prevents the root sheet from being
omitted when adding new sheets using the root sheet file name.
CHANGED: Make file name tests case sensitive so that schematic sheet
file names on non-Windows systems can be uses as expected.
Warn users when attempting to use schematic file names that only vary
by case sensitivity that doing so will result in a project that is not
portable to Windows.
Fixes lp:1843415
https://bugs.launchpad.net/kicad/+bug/1843415
They're now used for bus definition control characters.
Also fixes the sheet pin edit dialog to correctly escape/unescape
netnames.
Fixes: lp:1840834
* https://bugs.launchpad.net/kicad/+bug/1840834
The use of wxPATH_UNIX when calling GetFullPath() on windows drops the
volume identifier (c:\) from the file name which will cause comparison
failures.
Remove an existing sheet from the current page that requires a schematic
load from file to prevent a corrupt screen list from causing a segfault.
Merge the edit sheet file loading with the append schematic code since
they are functionally the same. This allows the sheet edit code to
take advantage of all of the added broken symbol library links added in
the recent append schematic fixes.
Fixes lp:1835841
https://bugs.launchpad.net/kicad/+bug/1835841
Don't edit sheet during AddToScreenAndUndoList() call. If it's
cancelled and we delete the item, callers will still own pointers
to the freed memory. Do it in New and Paste instead.
When importing an existing schematic into a sheet that was no remapped
to use the symbol library table, the user was given the option to ignore
the warning and proceed with the import. This would end up with all of
the imported symbol links being broke. In hindsight, this was a bad
idea so now the user cannot import schematics that have been remapped.
Fixes lp:1791280
https://bugs.launchpad.net/kicad/+bug/1791280
Previously, when creating a new instance of a sheet, the full set of references
was cleared.
Moreover, if this sheet has sub-sheets, the annotation was incorrectly handled
Now only (and all) new sheet path(s) created have a reference cleared, as expected.
(new sheet paths can be more than one, if the new instance of the sheet has sub-sheets)
Fixes: lp:1789048
https://bugs.launchpad.net/kicad/+bug/1789048
For the path separator in full filename, the sheet filename from the dialog uses the Unix notation,
and the "old" sheet filename uses the default notation (it is the actual filename).
Therefore, on Windows, after closing the dialog, the filename was always seen as modified,
and the hierarchy was incorrectly modified (annotation cleared).
The messages on sheet duplication are changed to reflect the action
perceived by the user when accepting/rejecting the change.
Annotation is also reset for duplicating sheets where maintaining
existing annotation would conflict with existing sheets.
Renaming a subsheet but keeping the filename should not present a
warning to the user. The was triggered due to comparing a
fully-qualified filename to a relative filename.
Fixes: lp:1744475
* https://bugs.launchpad.net/kicad/+bug/1744475
With the implementation of the legacy schematic plugin, any I/O error
when parsing the schematics would prevent the entire schematic from
being loaded. This change restores (somewhat) the previous behavior
where as long as the root schematic is loaded properly, then all of
the remaining sub-sheet will attempt to load.
Add GetError() method the SCH_PLUGIN object to allow for partial
schematic loading.
Check the error message contents when no exception was caught to warn
the user of any accumulated errors.
Fixes lp:1690644
https://bugs.launchpad.net/kicad/+bug/1690644
Use the legacy plugin schematic loader in the sheet edit and append
schematic code paths.
Check for fully qualified LIB_ID objects (must have library nickname)
when loading existing schematics when edit sheets.
Rewrite append schematic feature to handle import issues rather than
change the name and file name of all of the sheets in the imported
schematic. This includes the following:
- Load the schematic into a temporary SCH_SHEET object.
- Make sure the imported schematic does not cause any hierarchy
recursion issues.
- Verify the imported schematic uses fully qualified #LIB_ID objects
(symbol library table).
- Check to see if any symbol libraries need to be added to the current
project's symbol library table. This includes:
- Check if the symbol library already exists in the project or global
symbol library table.
- Convert symbol library URLS that use the ${KIPRJMOD} environment
variable to absolute paths. ${KIPRJMOD} will not be the same for
this project.
- Check for duplicate symbol library nicknames and change the new symbol
library nickname to prevent library name clashes.
- Update all schematic symbol LIB_ID object library nicknames when the
library nickname was changed to prevent clashes.
- Check for duplicate sheet names which is illegal and automatically
rename any duplicate sheets in the imported schematic.
- Clear all of the annotation in the imported schematic to prevent
clashes.
- Append the objects from the temporary sheet to the current page.
- Replace any duplicate time stamps.
- Refresh the symbol library links.
Add support code to SCH_SCREEN object to assist with schematic import.
Doxygen comment cleaning.
Fixes lp:1731760
https://bugs.launchpad.net/kicad/+bug/1731760