This method was using a case insensitive comparison to find the pad matching aPadName.
But in netlist we are using case sensitive comparisons to attribute a net to a pad.
So if in the netlist there is a pad name that does not match any footprint pad name using case sensitive comparison but if it matches some pads using case insensitive comparison, the net is not set, but the test to detect non existing pads fails.
Pads not on copper layers now do not have a netname, and are no longer taken in account in connectivity.
Especially it avoid creating useless rats-nests for these pads.
This fixes two display issues in the project template selector. The
first captured HTML tags in the template title display and the second
prevented more than one line for showing (at least on GTK) in the
preview. This prevented disambiguation between the various templates.
(cherry picked from commit 24b032ce5b)
This fixes the last suffix that was missed by 168fa09f5. The schematic
backup files should have the suffix .sch-bak to distinguish from
.kicad_pcb-bak or other backups.
(cherry picked from commit b6fe4ff637)
Setting stub width to a ridiculous large value (for instance 100 times the pad size) creates strange and broken shapes,
and obviously stubs cannot be built.
Ensure also the thermal shape is inside the zone boundary (because the algo adds areas this was previously possible)
Fixes: lp:1837559
https://bugs.launchpad.net/kicad/+bug/1837559
- make it wxWidgets 3.1 compatible.
- internationalize.
- fix minor wxwidgets alert.
- remove settings for fg/bg color: the result is unpredictable:
was black texts on black background on my computer.
Previously, for instance after modifying preferences or language,
they were rebuilt but the tools state was not set due to a missing call to SyncToolbars() after rebuilding.
Do not add cache library from another project to old library list. This
is wrong and can cause all kinds of symbol library linking issues. It's
better to force the user to fix broken symbol library links than the false
security of using multiple cache libraries.
Use correct paths when appending schematic outside of the current project
path when hierarchical sheets are appended. If the path can be relative,
give the user the option to use either relative or absolute paths.
Do not change symbol library names in schematics appended from a source
outside the current project. This will almost ensure the symbol library
links will be broken in the source project.
When the appended schematic is from another project, attempt to check all
of the possible combinations of symbol library table importing that could
cause broken symbol library links and give the user the option of canceling
the append operation or live with the possibility that there may be broken
symbol library links.
When the append schematic is in the current project path but not part of
the schematic, check to see if there are any library nicknames that do
no exist in the project symbol library table and give the user a chance
to cancel the append process.
This reverts commit eadf6d93bc.
because the issue with net names containing '/' is not actually inside the netlist.
This commit eadf creates issues with ngspice 2.8 and older, and do not fix anything in ngspice
This sets the clearance outline to a slightly better opacity to allow
viewing of items behind the routed track clearance. Future work should
include making this a configuration option.
Fixes: lp:1826719
* https://bugs.launchpad.net/kicad/+bug/1826719
(cherry picked from commit e0589d2908)
Previously, the background was highlighted, but not the text.
On Windows, the text was unreadable, until it was selected.
Now the foreground color is also set to the text selected color.
Similar to fix 34e00bdb6d, but for the fp editor.
- fix an issue when trying to enter a scale < 1.0: such a scale starts by 0, that was rejected by the filter)
- automatic clamp to user scale limits, to avoid many warnings to users.
- if the user scale is out of bounds, warn the user before trying to print, not when opening the dialog.