Commit Graph

35 Commits

Author SHA1 Message Date
Chris Pavlina a06e3bef33 Layer Setup: DPI-independent default size
Also, remove a wxPanel border as it makes device-independent sizing
nearly impossible. For some reason wxPanel::GetClientSize() is returning
garbage here and breaks centering text without fudge factors. I think it
still looks good without the border, maybe better.
2018-01-07 00:06:57 -07:00
Wayne Stambaugh ded4ad9b17 Pcbnew: delete objects from removed layers.
This fixes potential DRC false positive bugs that occur when inner layers
are removed from the board but the actual objects on contained on those
layers remain in the board.

Since Pcbnew does not handle odd number layers, this is not a perfect fix.
When the user chooses the front or back layer only options from the layer
setup dialog, objects on the copper layers will not be removed.  This will
not cause the false positive issue described above.

Get rid of dialog OK and cancel button event handlers and use the proper
TranferData(To/From)Window for handling control data.

Add PCB_LAYER_COLLECTOR for collecting board objects by layer.  Factor out
redundant [] operators into base PCB_COLLECTOR object.

Fixes lp:893950

https://bugs.launchpad.net/kicad/+bug/893950
2017-09-28 13:01:09 -04:00
Jon Evans 3ec28e2acf Refactor layer enumerations to all live in the same place 2017-03-30 16:01:48 -04:00
Simon Richter 59c81976dc Explicitly mark overriding functions. 2016-09-24 14:53:15 -04:00
jean-pierre charras 4dc2ece011 Fix a few wording issues in dialogs (dialog plot and dialog move exact) for translators (more explicit words/sentences to remove ambiguities).
Pcbnew: Plot files: for copper layers, create suffix from user copper layer names instead of default copper layer names, like in last stable Kicad version (bzr 4022), to build the plot files filenames.
Better test of illegal chars in plot filename, both in plot dialog and functions aclled by Python scripts.
Fix a Plotcontroller issue to make SetUseGerberExtensions() work as expected from Python scripts ( from  Henner Zeller'patch with a fix to be sure it works properly from a Python script)
Note also using Protel Gerber Extensions is now a bad practice, because the official Gerber extension is .gbr since X2 Gerber version. But some users still use them)
2015-10-20 20:03:07 +02:00
unknown c70f4a0706 Pcbnew: Increase board thickness limit from 3mm to 10mm 2015-06-14 20:18:34 +02:00
jean-pierre charras 53b8a8ca96 Pcbnew: add the board thickness setup in dialog_layers_setup.cpp (mainly for the 3D viewer) 2015-04-20 18:48:31 +02:00
jean-pierre charras 016eef39e4 Dialog layers setup: cosmetic enhancements (fix a very minor issue on Windows). Remove a not used and outdated file. 2015-04-19 13:09:35 +02:00
Blair Bonnett 2101324691 Fix wxGTK scrollbar assertion in Pcbnew layer setup dialog. 2015-02-28 11:48:39 -05:00
jean-pierre charras aa9de21cd7 Ref and Value for footprints: use now the layer color, not a specific color: this is needed by the fact these fields can be on an other layer than silk screen, and therefore must have the corresponding color
Also do not allow copper layers, solder paste and solder mask: put Ref or Value on these layers has no sense, and can create serious issues on the board.
2014-09-14 17:34:37 +02:00
Dick Hollenbeck add4d5eb6f re-work the LSET(int,...) constructor 2014-06-29 13:09:32 -05:00
Dick Hollenbeck 4578ea8b9e 1) Add 32 Cu Layers.
2) Change from legacy Cu stack to counting down from top=(F_Cu or 0).
   The old Cu stack required knowing the count of Cu layers to make
   sense of the layer number when converting to many exported file types.
   The new Cu stack is more commonly used, although ours still gives
   B_Cu a fixed number.
3) Introduce class LSET and enum LAYER_ID.
4) Change *.kicad_pcb file format version to 4 from 3.
5) Change fixed names Inner1_Cu-Inner14_Cu to In1_Cu-In30_Cu and their
   meanings are typically flipped.
6) Moved the #define LAYER_N_* stuff into legacy_plugin.cpp where they
   can die a quiet death, and switch to enum LAYER_ID symbols throughout.
7) Removed the LEGACY_PLUGIN::Save() and FootprintSave() functions.
   You will need to convert to the format immediately, *.kicad_pcb and
   *.kicad_mod (=pretty) since legacy format was never going to know
   about 32 Cu layers and additional technical layers and the reversed Cu
   stack.
2014-06-24 11:17:18 -05:00
Maciej Suminski 23392ce8c9 Upstream merge. 2014-04-02 15:38:59 +02:00
Maciej Suminski 87c9423f0f PCB_EDIT_FRAME::SetActiveLayer() & GetActiveLayer() made public. 2014-03-21 11:17:47 +01:00
jean-pierre charras 63401f3d95 Rework on 3D viewer (work in progress): Disable or enable layers, grid or 3D footprint shapes should be now faster. 2014-03-08 20:04:23 +01:00
Marco Serantoni d475c544c8 [MacOSX] Fixing resize issue in layer setup dialog 2014-02-21 17:38:29 +01:00
jean-pierre charras 902e5ccee5 pcb layer box selector: ajust size when modifying the layer names, to show the full name. 2013-09-02 17:26:52 +02:00
Lorenzo Marcantonio b525e3be55 Factored out text anchor drawing
More layer classification cleanup
2013-04-09 18:00:46 +02:00
Lorenzo Marcantonio 204d085b64 More cleanup on layer code usage
Better description for entities on right click menu and panel
Typo fixes and some comment reformats
2013-04-07 13:55:18 +02:00
Lorenzo Marcantonio 9fd79dfa91 Implemented the LAYER_NUM typedef (LAYER was already taken as a class name...) to represent a layer number. 2013-03-31 15:27:46 +02:00
Lorenzo Marcantonio e0303a4558 - New typedef LAYER_MSK to encapsulate a layer bitmap
- Renamed ReturnMaskLayer to GetLayerMask (since it's a plain getter)
2013-03-30 18:24:04 +01:00
Dick Hollenbeck 25b65b2e3b Consistent with my email posting from a day or two ago, remove the translated
standard layer name support from BOARD::GetLayerName().  This function evolved
in a contorted direction over time, and was being asked to return one of 3
different kinds of layer names, even though it only took a boolean to control
that choice.  

Users are better served by forcing them to get to know the concise new 
English Standard layer names.  This is because these concise names show up
in the "pretty" footprint/module files as the standard representation of
both feature and copper layers.

Change the name of BOARD::GetDefaultLayerName() to GetStandardLayerName().
Drop boolean argument to both BOARD::GetStandardLayerName() and 
BOARD::GetLayerName().
2013-03-19 23:46:32 -05:00
Dick Hollenbeck a9ccf49580 allow . in layer names 2012-12-10 23:39:36 -06:00
jean-pierre charras 7c0af1bf9d More dialogs derived from DIALO_SHIM 2012-10-04 08:57:15 +02:00
jean-pierre charras bae892dfe5 Pcbnew: make all dialogs derived from DIALOG_SHIM. 2012-10-03 13:25:30 +02:00
jean-pierre charras d9ed8a3085 Pcbnew: automatic selection of plugin when loading a file with .kicad_pcb extension from history list.
Very minor other fixes
2012-06-14 21:10:32 +02:00
Dick Hollenbeck e7b3ed2e88 merge 2012-02-06 01:14:51 -06:00
Dick Hollenbeck b8a0ab4c52 switch to <> for includes from "" per conversation with Jean-Pierre and Wayne, adjust search paths 2012-01-22 22:33:36 -06:00
Wayne Stambaugh 4b853dedb4 Application name capitalization fixes.
* Correct all user strings and comments for the correct capitalization of
  application names according to JP.  They are KiCad, Pcbnew, CvPcb,
  Eeschema, and GerbView.
* Add a note the the user interface policy about the correct capitalization.
2011-09-30 14:15:37 -04:00
Wayne Stambaugh edd35b4e90 PCB common library header rationalization.
* All header files used to create the PCB common library now compile as
  stand alone code.  This prevents the need to define them in a specific
  order to make source code compile properly.  It should also now be
  possible to relocate the source code to build the common PCB library
  to a separate folder.
2011-09-23 09:57:12 -04:00
Wayne Stambaugh ebc7259a91 Rename WinEDA_App class to EDA_APP and remove redundant includes. 2011-09-06 10:09:40 -04:00
Wayne Stambaugh fe6890a955 Dialog escape key termination and default button fixes.
* Fix about dialog escape key termination bug.
* Fix edit hot keys dialog escape key termination bug.
* Set schematic editor component properties dialog default button.
* Fix schematic editor plot DXF dialog escape key termination bug.
* Set PCB editor layers setup dialog default button.
* Set PCB editor swap layers dialog default button.
* Set PCB editor net list dialog default button.
* Add comment to UIPolicy.txt about escape key termination requiring proper
  dialog button IDs.
2011-03-14 15:17:42 -04:00
Wayne Stambaugh 1010601a78 PCBNew control update bug fixes, fixes lp:725963.
* Fix grid select box update bug on context menu.
* Fix via size and track width select box update bugs.
* Fix layer pair indicator button update bug.
* Fix auto track width tool bar control enable bug.
* Fix via size and track width select status bug in context menu.
* Fix layer select box and layer control widget select bug when current
  layer is removed.
* Add virtual function to notify objects derived from EDA_DRAW_FRAME that
  the units setting has changed.
* Coding policy class naming fixes.
2011-03-01 14:26:17 -05:00
jean-pierre charras 92952b70aa Use UTF-8 encoding only in kicad files. Under Linux, this was already the case. Under Windows, texts with non ascii characters must be corrected.
This ensure compatibility between platforms.
2011-02-28 19:36:19 +01:00
jean-pierre charras 1f47f8c6ed Pcbnew: files housekeeping and code cleanup 2010-11-26 21:00:39 +01:00
Renamed from pcbnew/dialog_layers_setup.cpp (Browse further)