The new connectivity algorithm had a tendency to cleanup
globally, but that could insert undo records from other sheets
into the current screen's undo stack. Needless to say, this
was a recipie for segfaults.
Fixes: lp:1846247
* https://bugs.launchpad.net/kicad/+bug/1846247
While it's tempting to look at the changed flag that TestDanglingEnds
returns, it's insuficient as the connectivity algorithm might have
already updated it (and ignored the changed flag).
Fixes: lp:1835107
* https://bugs.launchpad.net/kicad/+bug/1835107
Check for symbol libraries that somehow ended up in the project file
after remapping occurred and remove all of them to prevent potentially
broken symbol library links.
Add nagware dialog to warn the user and a checkbox to never show the
dialog again.
Fixes lp:1838185
https://bugs.launchpad.net/kicad/+bug/1838185
Also rewrites the PCBNew Find dialog to make use of the above, including:
1) searching in user-defined footprint fields
2) searching in pcb text
3) a history list in the search popup
4) case sensitive searching
5) word sensitive searching
6) the ability to turn wildcard searching on/off
7) better placement of the result when the dialog obscures part of the
window
Fixes: lp:1838006
* https://bugs.launchpad.net/kicad/+bug/1838006
Previously, for instance after modifying preferences or language,
they were rebuilt but the tools state was not set due to a missing call to SyncToolbars() after rebuilding.
In singletop mode, all frames show the "Quit" option in the file menu
and will quit on Ctrl-Q. When launched from the main KiCad interface,
sub-programs show the "Close" option instead and will close with Ctrl-W.
In this mode, Ctrl-Q will instruct the main program to exit.
Fixes: lp:1779938
* https://bugs.launchpad.net/kicad/+bug/1779938
EEschema optimizes wires by merging colinear segments. If a schematic opened without a valid
cache library or missing installed libraries and later saved, this optimization can cause connectivity
errors. In order to fix that we check each pin-wire connection and junctions if necessary.
Netlists do not accept any char in netnames (especially spice).
They must use only "/" as root sheet path name.
Especially _( "<root sheet>" ) breaks netlists because:
- there is a space in name, and special chars (< and >)
- it is a translatable name. so the actual name cannot be managed.
- most of netlist code in Kicad expects a "/" as root path.
Prefix the sheet name with "Sheet: " and the sheet file name with "File: "
when plotting so that it matches the display sheet rendering.
Improve the root sheet plot file name.
Fixes lp:1832081
https://bugs.launchpad.net/kicad/+bug/1832081
Also changes the presentation of the string when the checkbox appears
so that the "Changes will be lost" warning isn't hidden by the turndown.
This last part may require conditional compilation as it's undocumented.
Lastly, regularizes the Unsaved Changes strings between the apps.
These options were used to support the legacy canvas when drawing on
MacOS and GTK3. With the move to 100% GAL, they are extraneous. This
moves all DC over to "COPY" as we only use this for printing support in
Eeschema at the moment, so there is a single draw command (no erasing)
for the canvas.
This is a stop gap fix. It should be possible to use the wxFrame title
string for this but some of the frame windows have appropriated the title
string for configuration file naming purposes which is less than ideal.
Fixes lp:1825977
https://bugs.launchpad.net/kicad/+bug/1825977
It was confusing that the primary frames registered their tools
differently than the other frames. In addition, since the other
frames also added their own tools, foo_actions::RegisterAllTools()
didn't really register all tool but rather those used by the
principal frame (PCB_EDIT_FRAME, SCH_EDIT_FRAME, etc.)
Don't edit sheet during AddToScreenAndUndoList() call. If it's
cancelled and we delete the item, callers will still own pointers
to the freed memory. Do it in New and Paste instead.
OnModify() is called when staging the undo/redo modifications. This
requires that it not create changes that themselves need to be placed
in the undo/redo stack
This allows us to make the various netlist and pcb update routines
more atomic and less reliant on carefully sequenced asynchronous
messages.
This is also a prelude to adding support for footprint testing
without a netlist.
Save/restore default netclass.
Read layers back in with correct syntax ('.' between keyword and layer name).
Write layers to project file.
Read/write layer enablement bits.
Don't set solder paste margin min to 0 (most of them are negative).
Fixes: lp:1811990
* https://bugs.launchpad.net/kicad/+bug/1811990
Remove unnecessary calls to TestDanglingEnds()
Disable real-time connectivity updates for now
Revert "Remove unnecessary calls to TestDanglingEnds()"
This reverts commit d93e3894f2bcd6239862ac9eae0cb2f994b9d52a.
Remove debug code
Bus upgrades: core new connectivity code
Bus upgrades: eeschema integration and modifications
Bus upgrades: eeschema dialogs
Bus upgrades: netlist export
Bus upgrades: file format changes
Autosave was not working correctly, partly due to different
implementations in eeschema and pcbnew and partly due to a mistaken
refactor at some point during v5 development. This unifies the expected
autosave prefix to _autosave- for both pcbnew and eeschema. It also
unifies the expected suffix for the backup files to -bak.
Fixes: lp:1820433
* https://bugs.launchpad.net/kicad/+bug/1820433
For some reason, changing languages was causing the options (left) toolbar
to get redrawn with some of the main toolbar entries. Changing the window
size causes the toolbar to be redrawn correctly. The normal call to
function wxWindow::Refresh() does not.
Fixes lp:1816492
https://bugs.launchpad.net/kicad/+bug/1816492
This makes using Scrollbars more easy to use, especially for "small" page sizes like A or B.
Note also the working/drawing area size is bigger than the page size (3 times)
Split antialiasing options out from display options. Move
antialiasing to common. Duplicate the rest of display options
for Eeschema.
Implement OnSelectGrid and hookup GAL canvas refresh to
SetPresetGrid.
Add Grid Settings... to View menu and move Show Grid from
preferences to View Menu to match Pcbnew.
Previously, when creating a new instance of a sheet, the full set of references
was cleared.
Moreover, if this sheet has sub-sheets, the annotation was incorrectly handled
Now only (and all) new sheet path(s) created have a reference cleared, as expected.
(new sheet paths can be more than one, if the new instance of the sheet has sub-sheets)
Fixes: lp:1789048
https://bugs.launchpad.net/kicad/+bug/1789048
We have a dialog shim that raises the ERC dialog in front of the
schematic frame, which is useful for keeping the ERC dialog visible
during debugging. But mouse move events do not pass through to the
schematic, resulting in a captured mouse pointer but no drawing updates.
As a work-around we close the ERC dialog while placing new components.
Previous ERC data still exist when the window is launched again.
Fixes: lp:1779851
* https://bugs.launchpad.net/kicad/+bug/1779851