GetNet() refers to the net code stored in the NETINFO_ITEM. SetNet() finds an appropriate NETINFO_ITEM and uses it.
Removing GetNet() & SetNet() (and the whole net code idea) requires too many changes in the code (~250 references to the mentioned functions).
BOARD_CONNECTED_ITEMs by default get a pointer to NETINFO_ITEM that stores unconnected items. This requires for all BOARD_CONNECTED_ITEMs to have a parent (so BOARD* is accessible). The only orphaned item is BOARD_DESIGN_SETTINGS::m_Pad_Master, but it does not cause any issues so far.
Items that do not have access to a BOARD (do not have set parents) and therefore cannot get net assigned, by default get const static NETINFO_LIST::ORPHANED.
Performed tests:
- loaded .kicad_pcb, KiCad legacy board, Eagle 6.0 board, P-CAD board - all ok
- load a simple project, reload netlist after changing connections in eeschema - ok
- save & reload a board - ok, but still contain empty nets
- remove everything, restore with undo - ok
- remove everything, reload netlist - ok
- changing net names (all possibilites: empty->existing, empty->not existing, existing->empty, existing->not existing) - all ok
- zones: when net is changed to a net that does not have any nodes besides the zone itself, it does not get filled
- ZONE_CONTAINER::m_Netname field
- ZONE_CONTAINER::SetNetName()
- ZONE_CONTAINER::SetNet() [it uses the one in BOARD_CONNECTED_ITEM]
- ZONE_CONTAINER::GetNetName() [instead BOARD_CONNECTED_ITEM::GetNetname is used]
- ZONE_CONTAINER::SetNetNameFromNetCode()
Performed tests:
- Drawn a zone that belongs to a net, then modified schematics so the net does not exist anymore. After reloading the net list, all pads/tracks are updated. Zones still belongs to the net that does not exist in the schematic (but still exists in .kicad_pcb file). After running DRC, the zone becomes not filled.
- Undo & redo affects assignment of a polygon to a specific net (you may change net of a polygon, refill it and undo/redo the changes).
D_PAD::GetNetname() and D_PAD::GetShortNetname() were moved to BOARD_CONNECTED_ITEM. Now they use the net name stored in NETINFO_ITEM.
Moved some one-line functions from class_board_connected_item.cpp to class_board_connected_item.h.
Added a copyright notice, moved Doxygen comments from class_board_connected_item.cpp to class_board_connected_item.h.
I have some doubts if changes introduced pcbnew/dialogs/dialog_pad_properties.cpp do not break anything, but I could not find a test case that breaks the pcbnew.
Performed tests:
- changed pad's net name from empty to existent - ok, name was changed
- changed pad's net name from empty to nonexistent - ok, error message is displayed, net name stays empty
- changed pad's net name from existent to empty - ok, net name became empty
- changed pad's net name from existent to nonexistent - ok, error message is displayed, net name is not changed
- (re)reading netlists, including net changes - fine, changes are applied, but empty nets are still kept
- loaded pcbnew/pcad2kicadpcb_plugin/examples/CK1202_V1.pcb to test P-CAD import plugin - ok, net names are correct
- imported an Eagle 6.0 board (Arduino Uno; http://arduino.cc/en/uploads/Main/arduino_Uno_Rev3-02-TH.zip) then saved in .kicad_pcb format and reloaded - ok, net names are correct
- saved demos/video/video.kicad_pcb in legacy format and then loaded it again - ok, net names are correct
Net codes are updated upon net list update. (BOARD::ReplaceNetlist())
Added in some places (mostly class_board.cpp) pad->SetNet() calls to synchronize net codes.
On creation of NETINFO_LIST, the first NETINFO_ITEM is added (the unconnected items net).
Removed COMPONENT_NET::m_netNumber, as it was not used anywhere.
Added an assert to D_PAD::GetNetname(), checking if net code and net name is consistent for unconnected pads. Added an assert for NETINFO_LIST::AppendNet() to assure that appended nets are unique.
It seems that at this point:
- Updating net lists works fine. The only difference between the file ouput is that after changes it contains empty nets as well.
- Nets are not saved in the lexical order. Still, net names and net codes are properly assigned to all items in the .kicad_pcb file. It is going to be addressed in the next commit. I believe it should not create any problems, as pads are sorted by their net names anyway (NETINFO_LIST::buildPadsFullList())
Performed tests:
- Created a blank PCB, saved as pic_programmer.kicad_pcb (from demos folder). Updated net lists. .kicad_pcb file (comparing to the results from master branch) differ with net order (as mentioned before), net codes and timestamps.
- Removed some of components from the above .kicad_pcb file and updated net lists. Modules reappeared. .kicad_pcb file differs in the same way as described above.
- Trying to change a pad net name (via properties dialog) results in assert being fired. It is done on purpose (as there is a call to GetNetname() and net name and net code do not match). This will not happen after the next commit.
- Prepared a simple project (starting with schematics). Imported net list, changed schematic, reimported net list - changes are applied.
- Eagle & KiCad legacy boards seem to load without any problem.
NETINFO_ITEM::m_Net and NETINFO_ITEM::m_Netname are const.
Changes to be verified:
- pcbnew/minimun_spanning_tree.cpp: It segfaults is m_Size == 0
- pcbnew/exporters/export_gencad.cpp: I removed the SetNetname() call, as it changes only the unconnected net and in the next line it returns if the net is unconnected. Still, I wonder if name for the unconnected net matters. What about tests that check if a net name is empty to decide if it is unconnected net or not.