- Ensure a change in plugin type is detected
- do not force automatic plugin type selection for *.lib files that need
an access to these libraries: they can be not always available.
in GetMsgPanelInfo() (PPI, scale).
m_image name was confusing: it is not a wxImage, but a BITMAP_BASE item,
and m_image name was already in use in BITMAP_BASE, used inside SCH_IMAGE.
Bitmap properties dialog: show PPI value and add Title to dialog.
- Ensure that critical paths (ERC/netlister) are fully-rechecked
- Handle symbol/pin distinction in change markers
- Fully connect hierarchical pins in one pass descending
Previously, almost all connectivity updates were full updates, meaning
that the entire connectivity graph would be rebuilt each time a change
was made to the schematic. This update modifies the update to only
correct the subgraphs that are directly affected by the change.
It uses the existing connection graph to find all affected subgraphs as
well as connections to the changes based on the visible schematic.
These elements are removed from the existing connectivity graph and
marked dirty. They then have a new connectivity graph built only around
their changes. The resulting graph is merged into the original.
Currently, this ability is behind an advanced config flag
`IncrementalConnectivity` while testing.
Fixes https://gitlab.com/kicad/code/kicad/issues/10846
Fixes https://gitlab.com/kicad/code/kicad/issues/1794
Adds maximum step size setting used by transient analysis solver,
and 'use initial conditions (uic)' setting. Enabling uic disables
DC operating point analysis and may introduce singularities. It requires
a careful selection of initial conditions of circuit elements.
Fixes https://gitlab.com/kicad/code/kicad/issues/2515
Previously, bus elements that were not instantiated as individual nets
could not connect to each other. This caused issues for complex
schematics where busses needed to connect to other busses with elements
that resolved to the same net names. Functionally, this means mixing
bus elements, which we will replace with first-class elements in version
8 but currently can only be accomplished either by using bus aliases and
this patch or by individually instantiating each bus element as a
local label
Fixes https://gitlab.com/kicad/code/kicad/issues/14300
Move the internal columns and rebuild the table when a user moves the
columns. This is the only way to fix selection issues across reordered
columns.
Fixes: https://gitlab.com/kicad/code/kicad/-/issues/12295
Qty column can now be hidden.
We eventually need to get to the point that we are able to rearrange the
columns in the internal data model to work around wxGrid selection
issues.
The simulator has advanced considerably, and it is seeing lots of active
development, so make it a required part of KiCad. Additionally, the
build without the simulator has actually been broken for a while, so no
one clearly is building without ngspice right now.
1) More REPORTER, less exception processing
2) Remove UI calls from SPICE_MODEL
3) Don't replace netlist with errors; show both
4) Don't bail out of netlist generation after single error
Fixes https://gitlab.com/kicad/code/kicad/issues/14295