In the component, an m_unit/m_convert element is 1-indexed as opposed to
the library where they are 0-indexed. The 0-index in the library is
reserved for those elements that are shared across all conversion/unit
whereas it is invalid for the component.
Fixes: lp:1824764
* https://bugs.launchpad.net/kicad/+bug/1824764
(cherry picked from commit c4be74a9d0)
Bus upgrades: core new connectivity code
Bus upgrades: eeschema integration and modifications
Bus upgrades: eeschema dialogs
Bus upgrades: netlist export
Bus upgrades: file format changes
Uses existing grouping in SVG output. Sets schematic components as a
grouped element in SVG as well as pcbnew elements per layer.
Fixes: lp:1011754
* https://bugs.launchpad.net/kicad/+bug/1011754
No dangling symbol for text items with a NO-CONNECT.
DanglingStateChanged doesn't work with dangling flag aggregators
(which return true if any child is dangling).
Then again, we don't actually use any of the aggregators anyway
so I removed them.
Fixes: lp:1799589
* https://bugs.launchpad.net/kicad/+bug/1799589
Support all symbol orientations. (Yes, SCH_COMPONENT said only the
first 8 were used, but it lied.)
Fix cases where SetTextAttributes() was overwriting previously-
set justifications.
Correct rotation of vertical text.
Fix issue where bold global label would affect thickness of next
label's outline.
Previously, when creating a new instance of a sheet, the full set of references
was cleared.
Moreover, if this sheet has sub-sheets, the annotation was incorrectly handled
Now only (and all) new sheet path(s) created have a reference cleared, as expected.
(new sheet paths can be more than one, if the new instance of the sheet has sub-sheets)
Fixes: lp:1789048
https://bugs.launchpad.net/kicad/+bug/1789048
... and GetMsgPanelInfo.
Step 4 in the g_UserUnit eradication effort.
Also removes a couple of conversion routines that were close
enough to extinction.
(cherry picked from commit c75da51)
Clearing annotations should only clear the settings that can be set by
the matching annotate function. Even in components where the units are
functionally the same, the unit choice should be retained as there are
often other considerations when chosing the unit.
Fixes: lp:1769457
* https://bugs.launchpad.net/kicad/+bug/1769457
1) Commit in-progress edits before closing preferences.
2) Handle default fields in Symbol Fields Editor.
3) Save state of checkboxes in Symbol Fields Editor.
Nets assigned by power pins are weak, meaning they are valid
as long as there is nothing else attached to such pins. This patch
checks whether there are other wires or pins attached to a power pin
before placing a global net label.
Fixes: lp:1755191
* https://bugs.launchpad.net/kicad/+bug/1755191
When an attempt to resolve a library symbol link having a library
nickname that was no longer found in the symbol library table, the
symbol resolution was not falling back to the cache library due to
a silently handled exception. Add check for valid symbol library
table nickname before attempting to resolve symbol link to prevent
exception bypassing falling back to the cache library.
Fixes lp:1740609
https://bugs.launchpad.net/kicad/+bug/1740609