There are a whole bunch of cases which all have to work:
regular move
move followed by drag
drag followed by move
move followed by duplicate
duplicate
paste
and all both with and without Warp Mouse on Move checked.
Bus upgrades: core new connectivity code
Bus upgrades: eeschema integration and modifications
Bus upgrades: eeschema dialogs
Bus upgrades: netlist export
Bus upgrades: file format changes
No dangling symbol for text items with a NO-CONNECT.
DanglingStateChanged doesn't work with dangling flag aggregators
(which return true if any child is dangling).
Then again, we don't actually use any of the aggregators anyway
so I removed them.
Fixes: lp:1799589
* https://bugs.launchpad.net/kicad/+bug/1799589
Previously, when creating a new instance of a sheet, the full set of references
was cleared.
Moreover, if this sheet has sub-sheets, the annotation was incorrectly handled
Now only (and all) new sheet path(s) created have a reference cleared, as expected.
(new sheet paths can be more than one, if the new instance of the sheet has sub-sheets)
Fixes: lp:1789048
https://bugs.launchpad.net/kicad/+bug/1789048
... and GetMsgPanelInfo.
Step 4 in the g_UserUnit eradication effort.
Also removes a couple of conversion routines that were close
enough to extinction.
(cherry picked from commit c75da51)
1) Commit in-progress edits before closing preferences.
2) Handle default fields in Symbol Fields Editor.
3) Save state of checkboxes in Symbol Fields Editor.
Nets assigned by power pins are weak, meaning they are valid
as long as there is nothing else attached to such pins. This patch
checks whether there are other wires or pins attached to a power pin
before placing a global net label.
Fixes: lp:1755191
* https://bugs.launchpad.net/kicad/+bug/1755191
This adjusts the selection addition criteria for
blocks to allow items such as labels to connect to
lines not at the endpoints. It also uses the same
logic to correctly gather bus-wire, bus-bus entries.
Fixes: lp:1738941
* https://bugs.launchpad.net/kicad/+bug/1738941
Pins are weak_ptrs to the library, so they require a lock() before
accessing. This imposes a performance hit on fast loops that access
the pin list repeatedly. This patch caches the pin position locally
for each component, updating only when needed.
Fixes: lp:1737363
* https://bugs.launchpad.net/kicad/+bug/1737363
All of the schematic object load and save code is implemented in the
legacy schematic plugin so it is no longer required.
Remove unused file with old schematic file loader.
Doxygen comment cleaning.
Check the if the schematic being loaded has been remapped (no symbol
library table nicknames defined) and remap accordingly.
Fix issues when resolving the library symbol links in the schematic
symbols.
Add cache library fallback when resolving symbols that cannot be
remapped.
Add remap complete message to remap dialog.
Add HasLibrary() helper to LIB_TABLE_BASE.
Fix issues when loading library symbols using symbol library table.
Add hashing function to symbol library table.
Improve the symbol panel message to warn user when cache library is
used to resolve symbol.
Add Resolve() and ResolveAll() methods the SCH_COMPONENT object to use the
symbol library table to obtain links to the library symbols.
Add LoadAlias() method to SYMBOL_LIB_TABLE to find an alias by it's LIB_ID.
Clean up Doxygen comments to match coding policy changes.
- Allows grouping of matched components
- Bulk edit of components in a spreadsheet window
- User can choose to save / undo changes
- All changes are pushed to the undo stack in a single operation
- Export table to HTML / CSV output
Create dialog and code to allow legacy schematic symbols to be remapped
from the old library path look up method to the new symbol library table
method by using the following steps:
1) Create a project symbol library table containing all of the symbol
libraries defined in the old library look up list not found in the
global symbol library table.
2) Map each symbol to the correct symbol in the symbol library table
if possible.
Recreate library link to symbols so look up method can be converted to
symbol library table properly.
Add function to SCH_COMPONENT to link library symbols using the symbol
library table.
For some reason, rather than using the LIB_PART object reference by an
SCH_COMPONENT to check if a pin was at a given position in the schematic,
a LIB_PART search was performed for every component in a schematic. This
made absolutely no sense and was changed to use the LIB_PART referenced
by the SCH_COMPONENT object. This should significantly speed up any
operations that call SCH_SCREEN functions, IsTerminalPoint(),
MarkConnections(), and IsJunctionNeeded().
Add function to SCH_COMPONENT to access PART_REF object.