SCH_CONNECTION objects are temporary and can become stale any time the
connectivity is updated. Keeping them around to reference later is a
bad idea. Even if the object pointer is still valid in an SCH_ITEM in
the undo/redo buffers, comparing the pointer against another pointer as
a test to see if they are the same connection is not valid. Saving the
connection name is safe and ensures the connection is the same even if
the pointers differ.
(cherry picked from commit 831a6d55fc)
Pass 'false' as aStartAtCurrent to ReannotateByOptions(). Causes Pasing() symbols to start at the first available refdes after the currently
configured annotate start number, m_annotateStartNum.
Fixes#13342
And add tests to see if the file can be saved
Fix also an issue in sch_editor_control.cpp: The page setup dlg must generate changes
only if the OK button is clicked.
Fixes#13599https://gitlab.com/kicad/code/kicad/issues/13599
The pressure relief valve was not useful for common work patterns as it
forced the recalculation on many common actions such as bus expansion.
This caused it to actually feel slower than with the pressure relief
valve off.
For most schematics, realtime is now fast enough to not need the valve
and for those that are extremely complex, removing the valve helps this
run more predictably
We only need to parse the libraries for the Sim Model Editor dialog
(so that we can determine the models to put in the popup). Doing it
for netlisting just opens us up to incorrectly parsing the SPICE, and
returns no value.
This also means that a SIM_LIB_MGR manages a single library, and
never multiple libraries.
This also allows the tidying-up of some error reporting structures to
better inform the user what went wrong.
Fixes https://gitlab.com/kicad/code/kicad/issues/13431
When remapping the exported symbols, we should keep this in the undo
stack (remapping, not the existence of the new elements) and set the
dirty bit for the file to ensure it is saved/autosaved
Fixes https://gitlab.com/kicad/code/kicad/issues/13493
1) if a legacy model references a library then we need to see if said
libraray exists and read model from it if so
2) legacy node ordering is by index, not pin name
3) we can't auto-generate a pin map when we don't know the pin names,
so don't try
Also includes fixes for instance data and resolving of textvar
references.
Also includes virtual d'tors for IBIS parser to get rid of all the
compile warnings on CLang.
Fixes https://gitlab.com/kicad/code/kicad/issues/12357
This will make it possible to maintain sheet instance information when
copying and pasting from any sheet other that the root sheet of a
project.
Setting and getting sheet page numbers must now be performed using a
sheet path. This was done to ensure that the instance paths were not
getting changed unexpectedly from different code paths.
When pasting a symbol that originates in a non-standard library, the
symbol may _only_ have an instance in the sheet and so adding it to the
sheet updates the instance data and needs to be refreshed before
annotating