* Fixed spacing issue in pad properties dialog.
* Remove wxSHAPED flag from pad drawing panel to prevent assertion in
wxSizer.
* Used sane default pad size and drill size settings to prevent wxRound
assertions.
* Add license to class_board_design_settings.cpp.
Pcbnew: in netlist dialog: The user now can choose between the netlist and the .cmp file to import footprints names.
Therfore no need to delete the .cmp file when exists to use only the netlist.
This is useful for users who use CvPcb only once to fill footprints fields in schematic, and after edit/modify the footprints fields in schematic outside CvPcb.
* Improve MSG_PANEL_ITEM to handle message panel information.
* Create containers for passing message panel items between objects and
the message panel.
* Rename EDA_ITEM::DisplayInfo to EDA_ITEM::GetMsgPanelInfo.
* Remove all direct manipulation of EDA_DRAW_FRAME from all objects derived
from EDA_ITEM.
Pcbnew: Drc dialog: fix a old very minor bug.
Added: single click on an item in marker list moves the board graphic cursor on the corresponding marker location on the board
Double clicking is not modified.
* Fix offset errors when scale factor greater is than one.
* Changed behavior of fit in page when not drawing border and
title block to fit board outline in page.
* Fix offset errors when mirroring (still not 100% correct on MSW with
wxWidgets 2.9.4).
* Lots of the usual code cleaning and simplifying.
their type, by using the more abstract PLUGIN::Footprint*() functions.
This is an intermediate phase only, other changes will be necessary as library table support comes in.
Encapsulate usage of library path searching, since that will go away as library table support comes in.
Add FOOTPRINT_EDIT_FRAME::{get,set}LibPath() and FOOTPRINT_EDIT_FRAME::{get,set}LibNickName() functions
to provide this encapsulation.
* If this param is set to 0, the previous behavior is used.
* Else the solder mask is plotted as polygon, with shapes near than this min width value are merged.
Pcbnew in nanometer version: fix a serious rounding issue due to the fact dialogs were using 4 digits for mantissa.
* This is not enough for nanometer coordinates ( 8 are needed to display a value in inches),
* so sometimes after closing a dialog, some coordinates were modified, although no new value was entered.
Minor other bug fixed.
SVG export does not use no more wxWidgets wxDC.
In pcbnew SVG files can be created by plot menu (in B&W) or export SVG menu (B&W or Color).
Export SVG menu is more suitable to create a view of a board, and plot menu is better to create a B&W document of silkscreen layers.
(In the future, the 2 menus could be merged, because they are not very different).
Note: pcbnew plot code is cleaned, mainly in dialog files, but still needs more cleanup.