Create an IsContentModified() function in each frame
that provides if the content has been modified, and
use that instead of always copying the checks.
ADDED: a config option to select (when clicking on a pin) the parent symbol
or only the pin.
Previously, when cliking on a pin, the parent symbol was selected.
Allowing the pin selection is mandatory in cross probing, and to display the pin
characteristics in some cases, for instance if a pin is flagged by the ERC tooL.
Add missing check for root sheet when searching sheet hierarchies for
already loaded schematics. This prevents the root sheet from being
omitted when adding new sheets using the root sheet file name.
CHANGED: Make file name tests case sensitive so that schematic sheet
file names on non-Windows systems can be uses as expected.
Warn users when attempting to use schematic file names that only vary
by case sensitivity that doing so will result in a project that is not
portable to Windows.
Fixes lp:1843415
https://bugs.launchpad.net/kicad/+bug/1843415
CHANGED: No longer call schematics noname.sch in standalone mode,
instead don't given them any name so the user can choose on save.
Fixes: lp:1852607
* https://bugs.launchpad.net/kicad/+bug/1852607
The new connectivity algorithm had a tendency to cleanup
globally, but that could insert undo records from other sheets
into the current screen's undo stack. Needless to say, this
was a recipie for segfaults.
Fixes: lp:1846247
* https://bugs.launchpad.net/kicad/+bug/1846247
Check for symbol libraries that somehow ended up in the project file
after remapping occurred and remove all of them to prevent potentially
broken symbol library links.
Add nagware dialog to warn the user and a checkbox to never show the
dialog again.
Fixes lp:1838185
https://bugs.launchpad.net/kicad/+bug/1838185
Remove an existing sheet from the current page that requires a schematic
load from file to prevent a corrupt screen list from causing a segfault.
Merge the edit sheet file loading with the append schematic code since
they are functionally the same. This allows the sheet edit code to
take advantage of all of the added broken symbol library links added in
the recent append schematic fixes.
Fixes lp:1835841
https://bugs.launchpad.net/kicad/+bug/1835841
Also rewrites the PCBNew Find dialog to make use of the above, including:
1) searching in user-defined footprint fields
2) searching in pcb text
3) a history list in the search popup
4) case sensitive searching
5) word sensitive searching
6) the ability to turn wildcard searching on/off
7) better placement of the result when the dialog obscures part of the
window
Fixes: lp:1838006
* https://bugs.launchpad.net/kicad/+bug/1838006
Previously, for instance after modifying preferences or language,
they were rebuilt but the tools state was not set due to a missing call to SyncToolbars() after rebuilding.
Selecting in Eeschema has major issues, as does highlighting in
pcbnew. So for now we do highlighting in eeschema and selecting
in pcbnew. Improving highlighting for pcbnew would be the next
logical step....
Fixes: lp:1836640
* https://bugs.launchpad.net/kicad/+bug/1836640
EEschema optimizes wires by merging colinear segments. If a schematic opened without a valid
cache library or missing installed libraries and later saved, this optimization can cause connectivity
errors. In order to fix that we check each pin-wire connection and junctions if necessary.
This adds the functionality to add multiple labels to your schematic at
once by using spaces in the original label name.
Fixes: lp:1095113
* https://bugs.launchpad.net/kicad/+bug/1095113
It was escaped (replaced by "{slash}") in dialog.
This is right for labels, not for texts.
A consequence was the directives in spice simul can be broken.
Now the graphic text is not escaped.