kicad/qa/tests/eeschema/erc
Seth Hillbrand 55c864ec45 Fix incremental connectivity
The connectivity routine would consider symbols, overwriting unused
subgraphs for pins that were not in the change list.  This is resolved
by updating the full connectivity to only use pins in the graph since
symbols are not connected independently.

In the process of adding QA tests for this change, additional issues
with the schematic QA were discovered.  Specifically, we were not
properly setting the root sheet UUID.  This was partially masked by a
const_cast setting of the RefDes in sch_symbol when called the RefDes
getter.  This exposed the fact that our QA ERC numbers did not match the
schematic editor stand alone ERC numbers.  So the test value for one
check needed to be updated

Fixes https://gitlab.com/kicad/code/kicad/-/issues/17528

(cherry picked from commit a9f35ba42e)
2024-04-14 14:14:38 -07:00
..
test_erc_global_labels.cpp Dump the ERC report as part of the erc failure 2024-01-21 16:10:43 -05:00
test_erc_hierarchical_schematics.cpp Fix incremental connectivity 2024-04-14 14:14:38 -07:00
test_erc_label_not_connected.cpp Dump the ERC report as part of the erc failure 2024-01-21 16:10:43 -05:00
test_erc_no_connect.cpp Dump the ERC report as part of the erc failure 2024-01-21 16:10:43 -05:00
test_erc_stacking_pins.cpp Dump the ERC report as part of the erc failure 2024-01-21 16:10:43 -05:00