kicad/eeschema/netlist_exporters/netlist_generator.cpp

215 lines
6.9 KiB
C++

/*
* This program source code file is part of KiCad, a free EDA CAD application.
*
* Copyright (C) 1992-2018 jp.charras at wanadoo.fr
* Copyright (C) 2013 SoftPLC Corporation, Dick Hollenbeck <dick@softplc.com>
* Copyright (C) 1992-2021 KiCad Developers, see change_log.txt for contributors.
*
* This program is free software; you can redistribute it and/or
* modify it under the terms of the GNU General Public License
* as published by the Free Software Foundation; either version 2
* of the License, or (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program; if not, you may find one here:
* http://www.gnu.org/licenses/old-licenses/gpl-2.0.html
* or you may search the http://www.gnu.org website for the version 2 license,
* or you may write to the Free Software Foundation, Inc.,
* 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301, USA
*/
#include <common.h> // for ProcessExecute
#include <kicad_string.h>
#include <gestfich.h>
#include <sch_edit_frame.h>
#include <schematic.h>
#include <reporter.h>
#include <confirm.h>
#include <kiway.h>
#include <erc.h>
#include <netlist.h>
#include <netlist_exporter_base.h>
#include <netlist_exporter_orcadpcb2.h>
#include <netlist_exporter_cadstar.h>
#include <netlist_exporter_pspice.h>
#include <netlist_exporter_kicad.h>
#include <netlist_exporter_xml.h>
bool SCH_EDIT_FRAME::WriteNetListFile( int aFormat, const wxString& aFullFileName,
unsigned aNetlistOptions, REPORTER* aReporter )
{
// Ensure all power symbols have a valid reference
Schematic().GetSheets().AnnotatePowerSymbols();
// Ensure the netlist data is up to date:
RecalculateConnections( NO_CLEANUP );
if( !ReadyToNetlist( _( "Exporting netlist requires a fully annotated schematic." ) ) )
return false;
bool res = true;
bool executeCommandLine = false;
wxString fileName = aFullFileName;
NETLIST_EXPORTER_BASE *helper;
SCHEMATIC* sch = &Schematic();
switch( aFormat )
{
case NET_TYPE_PCBNEW:
helper = new NETLIST_EXPORTER_KICAD( sch );
break;
case NET_TYPE_ORCADPCB2:
helper = new NETLIST_EXPORTER_ORCADPCB2( sch );
break;
case NET_TYPE_CADSTAR:
helper = new NETLIST_EXPORTER_CADSTAR( sch );
break;
case NET_TYPE_SPICE:
helper = new NETLIST_EXPORTER_PSPICE( sch );
break;
default:
{
wxFileName tmpFile = fileName;
tmpFile.SetExt( GENERIC_INTERMEDIATE_NETLIST_EXT );
fileName = tmpFile.GetFullPath();
helper = new NETLIST_EXPORTER_XML( sch );
executeCommandLine = true;
}
break;
}
res = helper->WriteNetlist( fileName, aNetlistOptions );
delete helper;
// If user provided a plugin command line, execute it.
if( executeCommandLine && res && !m_netListerCommand.IsEmpty() )
{
wxString prj_dir = Prj().GetProjectPath();
// strip trailing '/'
prj_dir = prj_dir.SubString( 0, prj_dir.Len() - 2 );
// build full command line from user's format string.
// For instance, "xsltproc -o %O /usr/local/lib/kicad/plugins/netlist_form_pads-pcb.xsl %I"
// becomes, after the user selects /tmp/s1.net as the output file from the file dialog:
// "xsltproc -o /tmp/s1.net /usr/local/lib/kicad/plugins/netlist_form_pads-pcb.xsl /tmp/s1.xml"
wxString commandLine = NETLIST_EXPORTER_BASE::MakeCommandLine( m_netListerCommand,
fileName, aFullFileName,
prj_dir );
if( aReporter )
{
wxArrayString output, errors;
int diag = wxExecute( commandLine, output, errors, m_exec_flags );
wxString msg;
msg << _( "Run command:" ) << wxT( "\n" ) << commandLine << wxT( "\n\n" );
aReporter->ReportHead( msg, RPT_SEVERITY_ACTION );
if( diag != 0 )
{
msg.Printf( _( "Command error. Return code %d." ), diag );
aReporter->ReportTail( msg, RPT_SEVERITY_ERROR );
}
else
{
aReporter->ReportTail( _( "Success." ), RPT_SEVERITY_INFO );
}
if( output.GetCount() )
{
msg.Empty();
msg << wxT( "\n" ) << _( "Info messages:" ) << wxT( "\n" );
aReporter->Report( msg, RPT_SEVERITY_INFO );
for( unsigned ii = 0; ii < output.GetCount(); ii++ )
aReporter->Report( output[ii] + wxT( "\n" ), RPT_SEVERITY_INFO );
}
if( errors.GetCount() )
{
msg.Empty();
msg << wxT("\n") << _( "Error messages:" ) << wxT( "\n" );
aReporter->Report( msg, RPT_SEVERITY_INFO );
for( unsigned ii = 0; ii < errors.GetCount(); ii++ )
aReporter->Report( errors[ii] + wxT( "\n" ), RPT_SEVERITY_ERROR );
}
}
else
{
ProcessExecute( commandLine, m_exec_flags );
}
DefaultExecFlags(); // Reset flags to default after executing
}
return res;
}
bool SCH_EDIT_FRAME::ReadyToNetlist( const wxString& aAnnotateMessage )
{
// Ensure all power symbols have a valid reference
Schematic().GetSheets().AnnotatePowerSymbols();
// Components must be annotated
if( CheckAnnotate( []( ERCE_T, const wxString&, SCH_REFERENCE*, SCH_REFERENCE* ) {} ) )
{
// Schematic must be annotated: call Annotate dialog and tell the user why.
ModalAnnotate( aAnnotateMessage );
if( CheckAnnotate( []( ERCE_T, const wxString&, SCH_REFERENCE*, SCH_REFERENCE* ) {} ) )
return false;
}
// Test duplicate sheet names:
ERC_TESTER erc( &Schematic() );
if( erc.TestDuplicateSheetNames( false ) > 0 )
{
if( !IsOK( this, _( "Error: duplicate sheet names. Continue?" ) ) )
return false;
}
return true;
}
void SCH_EDIT_FRAME::sendNetlistToCvpcb()
{
std::string packet;
{
NETLIST_EXPORTER_KICAD exporter( &Schematic() );
STRING_FORMATTER formatter;
// @todo : trim GNL_ALL down to minimum for CVPCB
exporter.Format( &formatter, GNL_ALL );
packet = formatter.GetString(); // an abbreviated "kicad" (s-expr) netlist
// NETLIST_EXPORTER_KICAD must go out of scope so it can clean up things like the
// current sheet setting before sending expressmail
}
Kiway().ExpressMail( FRAME_CVPCB, MAIL_EESCHEMA_NETLIST, packet, this );
}