908 lines
30 KiB
C++
908 lines
30 KiB
C++
/*
|
|
* This program source code file is part of KiCad, a free EDA CAD application.
|
|
*
|
|
* Copyright (C) 2013 Jean-Pierre Charras, jp.charras at wanadoo.fr
|
|
* Copyright (C) 2013 Wayne Stambaugh <stambaughw@gmail.com>
|
|
* Copyright (C) 2013 CERN (www.cern.ch)
|
|
* Copyright (C) 1992-2020 KiCad Developers, see AUTHORS.txt for contributors.
|
|
*
|
|
* This program is free software; you can redistribute it and/or
|
|
* modify it under the terms of the GNU General Public License
|
|
* as published by the Free Software Foundation; either version 2
|
|
* of the License, or (at your option) any later version.
|
|
*
|
|
* This program is distributed in the hope that it will be useful,
|
|
* but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
* GNU General Public License for more details.
|
|
*
|
|
* You should have received a copy of the GNU General Public License
|
|
* along with this program; if not, you may find one here:
|
|
* http://www.gnu.org/licenses/old-licenses/gpl-2.0.html
|
|
* or you may search the http://www.gnu.org website for the version 2 license,
|
|
* or you may write to the Free Software Foundation, Inc.,
|
|
* 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301, USA
|
|
*/
|
|
|
|
#include <fctsys.h>
|
|
#include <sch_draw_panel.h>
|
|
#include <confirm.h>
|
|
#include <gestfich.h>
|
|
#include <sch_edit_frame.h>
|
|
#include <pgm_base.h>
|
|
#include <kiface_i.h>
|
|
#include <richio.h>
|
|
#include <trace_helpers.h>
|
|
#include <tool/tool_manager.h>
|
|
#include <id.h>
|
|
#include <class_library.h>
|
|
#include <lib_edit_frame.h>
|
|
#include <sch_sheet.h>
|
|
#include <sch_sheet_path.h>
|
|
#include <sch_component.h>
|
|
#include <wildcards_and_files_ext.h>
|
|
#include <project_rescue.h>
|
|
#include <eeschema_config.h>
|
|
#include <eeschema_settings.h>
|
|
#include <sch_legacy_plugin.h>
|
|
#include <sch_eagle_plugin.h>
|
|
#include <symbol_lib_table.h>
|
|
#include <dialog_symbol_remap.h>
|
|
#include <dialog_migrate_buses.h>
|
|
#include <ws_data_model.h>
|
|
#include <connection_graph.h>
|
|
#include <tool/actions.h>
|
|
#include <netlist.h>
|
|
|
|
|
|
bool SCH_EDIT_FRAME::SaveEEFile( SCH_SHEET* aSheet, bool aSaveUnderNewName,
|
|
bool aCreateBackupFile )
|
|
{
|
|
wxString msg;
|
|
wxFileName schematicFileName;
|
|
bool success;
|
|
|
|
if( aSheet == NULL )
|
|
aSheet = GetCurrentSheet().Last();
|
|
|
|
SCH_SCREEN* screen = aSheet->GetScreen();
|
|
|
|
wxCHECK( screen, false );
|
|
|
|
// If no name exists in the window yet - save as new.
|
|
if( screen->GetFileName().IsEmpty() )
|
|
aSaveUnderNewName = true;
|
|
|
|
// Construct the name of the file to be saved
|
|
schematicFileName = Prj().AbsolutePath( screen->GetFileName() );
|
|
|
|
if( aSaveUnderNewName )
|
|
{
|
|
wxString wildcards = KiCadSchematicFileWildcard();
|
|
|
|
wildcards += "|" + LegacySchematicFileWildcard();
|
|
|
|
wxFileDialog dlg( this, _( "Schematic Files" ), wxPathOnly( Prj().GetProjectFullName() ),
|
|
schematicFileName.GetFullName(), wildcards,
|
|
wxFD_SAVE | wxFD_OVERWRITE_PROMPT );
|
|
|
|
if( dlg.ShowModal() == wxID_CANCEL )
|
|
return false;
|
|
|
|
schematicFileName = dlg.GetPath();
|
|
|
|
if( dlg.GetFilterIndex() == 1
|
|
&& schematicFileName.GetExt() != LegacySchematicFileExtension )
|
|
schematicFileName.SetExt( LegacySchematicFileExtension );
|
|
else if( dlg.GetFilterIndex() == 0
|
|
&& schematicFileName.GetExt() != KiCadSchematicFileExtension )
|
|
schematicFileName.SetExt( KiCadSchematicFileExtension );
|
|
}
|
|
|
|
if( !IsWritable( schematicFileName ) )
|
|
return false;
|
|
|
|
// Create backup if requested
|
|
if( aCreateBackupFile && schematicFileName.FileExists() )
|
|
{
|
|
wxFileName backupFileName = schematicFileName;
|
|
|
|
// Rename the old file to a '-bak' suffixed one:
|
|
backupFileName.SetExt( schematicFileName.GetExt() + GetBackupSuffix() );
|
|
|
|
if( backupFileName.FileExists() )
|
|
wxRemoveFile( backupFileName.GetFullPath() );
|
|
|
|
if( !wxRenameFile( schematicFileName.GetFullPath(), backupFileName.GetFullPath() ) )
|
|
{
|
|
msg.Printf( _( "Could not save backup of file \"%s\"" ),
|
|
schematicFileName.GetFullPath() );
|
|
DisplayError( this, msg );
|
|
}
|
|
}
|
|
|
|
// Save
|
|
wxLogTrace( traceAutoSave,
|
|
wxT( "Saving file <" ) + schematicFileName.GetFullPath() + wxT( ">" ) );
|
|
|
|
SCH_IO_MGR::SCH_FILE_T pluginType = SCH_IO_MGR::GuessPluginTypeFromSchPath(
|
|
schematicFileName.GetFullPath() );
|
|
SCH_PLUGIN::SCH_PLUGIN_RELEASER pi( SCH_IO_MGR::FindPlugin( pluginType ) );
|
|
|
|
try
|
|
{
|
|
pi->Save( schematicFileName.GetFullPath(), aSheet, &Kiway() );
|
|
success = true;
|
|
}
|
|
catch( const IO_ERROR& ioe )
|
|
{
|
|
msg.Printf( _( "Error saving schematic file \"%s\".\n%s" ),
|
|
schematicFileName.GetFullPath(), ioe.What() );
|
|
DisplayError( this, msg );
|
|
|
|
msg.Printf( _( "Failed to save \"%s\"" ), schematicFileName.GetFullPath() );
|
|
AppendMsgPanel( wxEmptyString, msg, CYAN );
|
|
|
|
success = false;
|
|
}
|
|
|
|
if( success )
|
|
{
|
|
// Delete auto save file.
|
|
wxFileName autoSaveFileName = schematicFileName;
|
|
autoSaveFileName.SetName( GetAutoSaveFilePrefix() + schematicFileName.GetName() );
|
|
|
|
if( autoSaveFileName.FileExists() )
|
|
{
|
|
wxLogTrace( traceAutoSave,
|
|
wxT( "Removing auto save file <" ) + autoSaveFileName.GetFullPath() +
|
|
wxT( ">" ) );
|
|
|
|
wxRemoveFile( autoSaveFileName.GetFullPath() );
|
|
}
|
|
|
|
// Update the screen and frame info and reset the lock file.
|
|
if( aSaveUnderNewName )
|
|
{
|
|
screen->SetFileName( schematicFileName.GetFullPath() );
|
|
LockFile( schematicFileName.GetFullPath() );
|
|
}
|
|
|
|
screen->ClrSave();
|
|
screen->ClrModify();
|
|
|
|
msg.Printf( _( "File %s saved" ), screen->GetFileName() );
|
|
SetStatusText( msg, 0 );
|
|
}
|
|
else
|
|
{
|
|
DisplayError( this, _( "File write operation failed." ) );
|
|
}
|
|
|
|
return success;
|
|
}
|
|
|
|
|
|
void SCH_EDIT_FRAME::Save_File( bool doSaveAs )
|
|
{
|
|
if( doSaveAs )
|
|
{
|
|
if( SaveEEFile( NULL, true ) )
|
|
{
|
|
SCH_SCREEN* screen = GetScreen();
|
|
|
|
wxCHECK( screen, /* void */ );
|
|
|
|
wxFileName fn = screen->GetFileName();
|
|
|
|
if( fn.GetExt() == LegacySchematicFileExtension )
|
|
CreateArchiveLibraryCacheFile( true );
|
|
}
|
|
}
|
|
else
|
|
{
|
|
SaveEEFile( NULL );
|
|
}
|
|
|
|
UpdateTitle();
|
|
}
|
|
|
|
|
|
bool SCH_EDIT_FRAME::OpenProjectFiles( const std::vector<wxString>& aFileSet, int aCtl )
|
|
{
|
|
// implement the pseudo code from KIWAY_PLAYER.h:
|
|
wxString msg;
|
|
|
|
auto cfg = dynamic_cast<EESCHEMA_SETTINGS*>( Kiface().KifaceSettings() );
|
|
|
|
// This is for python:
|
|
if( aFileSet.size() != 1 )
|
|
{
|
|
msg.Printf( "Eeschema:%s() takes only a single filename.", __WXFUNCTION__ );
|
|
DisplayError( this, msg );
|
|
return false;
|
|
}
|
|
|
|
wxString fullFileName( aFileSet[0] );
|
|
|
|
// We insist on caller sending us an absolute path, if it does not, we say it's a bug.
|
|
wxASSERT_MSG( wxFileName( fullFileName ).IsAbsolute(), wxT( "Path is not absolute!" ) );
|
|
|
|
if( !LockFile( fullFileName ) )
|
|
{
|
|
msg.Printf( _( "Schematic file \"%s\" is already open." ), fullFileName );
|
|
DisplayError( this, msg );
|
|
return false;
|
|
}
|
|
|
|
if( !AskToSaveChanges() )
|
|
return false;
|
|
|
|
wxFileName pro = fullFileName;
|
|
pro.SetExt( ProjectFileExtension );
|
|
|
|
bool is_new = !wxFileName::IsFileReadable( fullFileName );
|
|
|
|
// If its a non-existent schematic and caller thinks it exists
|
|
if( is_new && !( aCtl & KICTL_CREATE ) )
|
|
{
|
|
// notify user that fullFileName does not exist, ask if user wants to create it.
|
|
msg.Printf( _( "Schematic \"%s\" does not exist. Do you wish to create it?" ),
|
|
fullFileName );
|
|
|
|
if( !IsOK( this, msg ) )
|
|
return false;
|
|
}
|
|
|
|
// unload current project file before loading new
|
|
{
|
|
SetScreen( nullptr );
|
|
delete g_RootSheet;
|
|
|
|
if( g_CurrentSheet )
|
|
g_CurrentSheet->clear();
|
|
|
|
g_RootSheet = nullptr;
|
|
|
|
CreateScreens();
|
|
}
|
|
|
|
GetScreen()->SetFileName( fullFileName );
|
|
g_RootSheet->SetFileName( fullFileName );
|
|
|
|
SetStatusText( wxEmptyString );
|
|
ClearMsgPanel();
|
|
|
|
SCH_IO_MGR::SCH_FILE_T schFileType = SCH_IO_MGR::GuessPluginTypeFromSchPath( fullFileName );
|
|
|
|
// PROJECT::SetProjectFullName() is an impactful function. It should only be
|
|
// called under carefully considered circumstances.
|
|
|
|
// The calling code should know not to ask me here to change projects unless
|
|
// it knows what consequences that will have on other KIFACEs running and using
|
|
// this same PROJECT. It can be very harmful if that calling code is stupid.
|
|
|
|
if( schFileType == SCH_IO_MGR::SCH_LEGACY )
|
|
{
|
|
// Don't reload the symbol libraries if we are just launching Eeschema from KiCad again.
|
|
// They are already saved in the kiface project object.
|
|
if( pro.GetFullPath() != Prj().GetProjectFullName()
|
|
|| !Prj().GetElem( PROJECT::ELEM_SCH_PART_LIBS ) )
|
|
{
|
|
Prj().SetProjectFullName( pro.GetFullPath() );
|
|
|
|
// load the libraries here, not in SCH_SCREEN::Draw() which is a context
|
|
// that will not tolerate DisplayError() dialog since we're already in an
|
|
// event handler in there.
|
|
// And when a schematic file is loaded, we need these libs to initialize
|
|
// some parameters (links to PART LIB, dangling ends ...)
|
|
Prj().SetElem( PROJECT::ELEM_SCH_PART_LIBS, NULL );
|
|
Prj().SchLibs();
|
|
}
|
|
}
|
|
else
|
|
{
|
|
// No legacy symbol libraries including the cache are loaded with the new file format.
|
|
Prj().SetElem( PROJECT::ELEM_SCH_PART_LIBS, NULL );
|
|
}
|
|
|
|
LoadProjectFile();
|
|
|
|
// Load the symbol library table, this will be used forever more.
|
|
Prj().SetElem( PROJECT::ELEM_SYMBOL_LIB_TABLE, NULL );
|
|
Prj().SchSymbolLibTable();
|
|
|
|
SetShutdownBlockReason( _( "Schematic file changes are unsaved" ) );
|
|
|
|
if( is_new )
|
|
{
|
|
// mark new, unsaved file as modified.
|
|
GetScreen()->SetModify();
|
|
}
|
|
else
|
|
{
|
|
SetScreen( nullptr );
|
|
delete g_RootSheet; // Delete the current project.
|
|
g_RootSheet = NULL; // Force CreateScreens() to build new empty project on load failure.
|
|
|
|
SCH_PLUGIN* plugin = SCH_IO_MGR::FindPlugin( schFileType );
|
|
SCH_PLUGIN::SCH_PLUGIN_RELEASER pi( plugin );
|
|
|
|
// This will rename the file if there is an autosave and the user want to recover
|
|
CheckForAutoSaveFile( fullFileName );
|
|
|
|
try
|
|
{
|
|
g_RootSheet = pi->Load( fullFileName, &Kiway() );
|
|
|
|
g_CurrentSheet = new SCH_SHEET_PATH();
|
|
g_CurrentSheet->clear();
|
|
g_CurrentSheet->push_back( g_RootSheet );
|
|
|
|
if( !pi->GetError().IsEmpty() )
|
|
{
|
|
DisplayErrorMessage( this,
|
|
_( "The entire schematic could not be loaded. Errors "
|
|
"occurred attempting to load \nhierarchical sheet "
|
|
"schematics." ),
|
|
pi->GetError() );
|
|
}
|
|
}
|
|
catch( const IO_ERROR& ioe )
|
|
{
|
|
// Do not leave g_RootSheet == NULL because it is expected to be
|
|
// a valid sheet. Therefore create a dummy empty root sheet and screen.
|
|
CreateScreens();
|
|
m_toolManager->RunAction( ACTIONS::zoomFitScreen, true );
|
|
|
|
msg.Printf( _( "Error loading schematic file \"%s\".\n%s" ),
|
|
fullFileName, ioe.What() );
|
|
DisplayError( this, msg );
|
|
|
|
msg.Printf( _( "Failed to load \"%s\"" ), fullFileName );
|
|
AppendMsgPanel( wxEmptyString, msg, CYAN );
|
|
|
|
return false;
|
|
}
|
|
|
|
// It's possible the schematic parser fixed errors due to bugs so warn the user
|
|
// that the schematic has been fixed (modified).
|
|
SCH_SHEET_LIST sheetList( g_RootSheet );
|
|
|
|
if( sheetList.IsModified() )
|
|
{
|
|
DisplayInfoMessage( this,
|
|
_( "An error was found when loading the schematic that has "
|
|
"been automatically fixed. Please save the schematic to "
|
|
"repair the broken file or it may not be usable with other "
|
|
"versions of KiCad." ) );
|
|
}
|
|
|
|
UpdateFileHistory( fullFileName );
|
|
|
|
SCH_SCREENS schematic;
|
|
|
|
// LIB_ID checks and symbol rescue only apply to the legacy file formats.
|
|
if( schFileType == SCH_IO_MGR::SCH_LEGACY )
|
|
{
|
|
// Convert old projects over to use symbol library table.
|
|
if( schematic.HasNoFullyDefinedLibIds() )
|
|
{
|
|
DIALOG_SYMBOL_REMAP dlgRemap( this );
|
|
|
|
dlgRemap.ShowQuasiModal();
|
|
}
|
|
else
|
|
{
|
|
// Double check to ensure no legacy library list entries have been
|
|
// added to the projec file symbol library list.
|
|
wxString paths;
|
|
wxArrayString libNames;
|
|
|
|
PART_LIBS::LibNamesAndPaths( &Prj(), false, &paths, &libNames );
|
|
|
|
if( !libNames.IsEmpty() )
|
|
{
|
|
if( eeconfig()->m_Appearance.show_illegal_symbol_lib_dialog )
|
|
{
|
|
wxRichMessageDialog invalidLibDlg(
|
|
this,
|
|
_( "Illegal entry found in project file symbol library list." ),
|
|
_( "Project Load Warning" ),
|
|
wxOK | wxCENTER | wxICON_EXCLAMATION );
|
|
invalidLibDlg.ShowDetailedText(
|
|
_( "Symbol libraries defined in the project file symbol library "
|
|
"list are no longer supported and will be\nremoved. This may "
|
|
"cause broken symbol library links under certain conditions." ) );
|
|
invalidLibDlg.ShowCheckBox( _( "Do not show this dialog again." ) );
|
|
invalidLibDlg.ShowModal();
|
|
eeconfig()->m_Appearance.show_illegal_symbol_lib_dialog =
|
|
!invalidLibDlg.IsCheckBoxChecked();
|
|
}
|
|
|
|
libNames.Clear();
|
|
paths.Clear();
|
|
PART_LIBS::LibNamesAndPaths( &Prj(), true, &paths, &libNames );
|
|
}
|
|
|
|
if( !cfg || !cfg->m_RescueNeverShow )
|
|
RescueSymbolLibTableProject( false );
|
|
}
|
|
|
|
// Update all symbol library links for all sheets.
|
|
schematic.UpdateSymbolLinks();
|
|
|
|
if( !cfg || cfg->m_Appearance.show_sexpr_file_convert_warning )
|
|
{
|
|
wxRichMessageDialog newFileFormatDlg(
|
|
this,
|
|
_( "The schematic file will be converted to the new file format on save." ),
|
|
_( "Project Load Warning" ),
|
|
wxOK | wxCENTER | wxICON_EXCLAMATION );
|
|
newFileFormatDlg.ShowDetailedText(
|
|
_( "This schematic was saved in the legacy file format which is no "
|
|
"longer supported and will be saved\nusing the new file format. The "
|
|
"new file format cannot be opened with previous versions of KiCad." ) );
|
|
newFileFormatDlg.ShowCheckBox( _( "Do not show this dialog again." ) );
|
|
newFileFormatDlg.ShowModal();
|
|
|
|
if( cfg )
|
|
cfg->m_Appearance.show_sexpr_file_convert_warning =
|
|
!newFileFormatDlg.IsCheckBoxChecked();
|
|
}
|
|
|
|
// Allow the schematic to be saved to new file format without making any edits.
|
|
OnModify();
|
|
}
|
|
else // S-expression schematic.
|
|
{
|
|
for( SCH_SCREEN* screen = schematic.GetFirst(); screen; screen = schematic.GetNext() )
|
|
screen->UpdateLocalLibSymbolLinks();
|
|
|
|
// Restore all of the loaded symbol instances from the root sheet screen.
|
|
sheetList.UpdateSymbolInstances( g_RootSheet->GetScreen()->m_symbolInstances );
|
|
}
|
|
|
|
g_ConnectionGraph->Reset();
|
|
|
|
SetScreen( g_CurrentSheet->LastScreen() );
|
|
|
|
// Migrate conflicting bus definitions
|
|
// TODO(JE) This should only run once based on schematic file version
|
|
if( g_ConnectionGraph->GetBusesNeedingMigration().size() > 0 )
|
|
{
|
|
DIALOG_MIGRATE_BUSES dlg( this );
|
|
dlg.ShowQuasiModal();
|
|
RecalculateConnections( NO_CLEANUP );
|
|
OnModify();
|
|
}
|
|
|
|
GetScreen()->TestDanglingEnds(); // Only perform the dangling end test on root sheet.
|
|
RecalculateConnections( GLOBAL_CLEANUP );
|
|
GetScreen()->ClearUndoORRedoList( GetScreen()->m_UndoList, 1 );
|
|
GetScreen()->m_Initialized = true;
|
|
}
|
|
|
|
GetScreen()->SetGrid( ID_POPUP_GRID_LEVEL_1000 + m_LastGridSizeId );
|
|
m_toolManager->RunAction( ACTIONS::zoomFitScreen, true );
|
|
SetSheetNumberAndCount();
|
|
|
|
// re-create junctions if needed. Eeschema optimizes wires by merging
|
|
// colinear segments. If a schematic is saved without a valid
|
|
// cache library or missing installed libraries, this can cause connectivity errors
|
|
// unless junctions are added.
|
|
FixupJunctions();
|
|
|
|
SyncView();
|
|
GetScreen()->ClearDrawingState();
|
|
|
|
UpdateTitle();
|
|
|
|
// If requested, generate a netlist and exit immediately.
|
|
// NOTE: This is intended as a developer-only feature for now, and can be removed in lieu of
|
|
// Python scripting once that is possible.
|
|
if( m_generateNetlistAndExit )
|
|
{
|
|
wxLogDebug( wxT( "Writing netlist to %s and exiting..." ), m_netlistFilename );
|
|
NETLIST_OBJECT_LIST* netlist = CreateNetlist( false, false );
|
|
WriteNetListFile( netlist, NET_TYPE_PCBNEW, m_netlistFilename, 0, nullptr );
|
|
Close( false );
|
|
}
|
|
|
|
return true;
|
|
}
|
|
|
|
|
|
bool SCH_EDIT_FRAME::AppendSchematic()
|
|
{
|
|
wxString fullFileName;
|
|
SCH_SCREEN* screen = GetScreen();
|
|
|
|
if( !screen )
|
|
{
|
|
wxLogError( wxT( "Document not ready, cannot import" ) );
|
|
return false;
|
|
}
|
|
|
|
// open file chooser dialog
|
|
wxString path = wxPathOnly( Prj().GetProjectFullName() );
|
|
|
|
wxFileDialog dlg( this, _( "Append Schematic" ), path, wxEmptyString,
|
|
KiCadSchematicFileWildcard(), wxFD_OPEN | wxFD_FILE_MUST_EXIST );
|
|
|
|
if( dlg.ShowModal() == wxID_CANCEL )
|
|
return false;
|
|
|
|
fullFileName = dlg.GetPath();
|
|
|
|
if( !LoadSheetFromFile( GetCurrentSheet().Last(), &GetCurrentSheet(), fullFileName ) )
|
|
return false;
|
|
|
|
SCH_SCREENS screens( GetCurrentSheet().Last() );
|
|
screens.TestDanglingEnds();
|
|
|
|
GetScreen()->SetGrid( ID_POPUP_GRID_LEVEL_1000 + m_LastGridSizeId );
|
|
m_toolManager->RunAction( ACTIONS::zoomFitScreen, true );
|
|
SetSheetNumberAndCount();
|
|
|
|
SyncView();
|
|
HardRedraw(); // Full reinit of the current screen and the display.
|
|
OnModify();
|
|
|
|
return true;
|
|
}
|
|
|
|
|
|
void SCH_EDIT_FRAME::OnAppendProject( wxCommandEvent& event )
|
|
{
|
|
if( GetScreen() && GetScreen()->IsModified() )
|
|
{
|
|
wxString msg = _( "This operation cannot be undone.\n\n"
|
|
"Do you want to save the current document before proceeding?" );
|
|
|
|
if( IsOK( this, msg ) )
|
|
SaveProject();
|
|
}
|
|
|
|
AppendSchematic();
|
|
}
|
|
|
|
|
|
void SCH_EDIT_FRAME::OnImportProject( wxCommandEvent& aEvent )
|
|
{
|
|
if( !AskToSaveChanges() )
|
|
return;
|
|
|
|
// Set the project location if none is set
|
|
bool setProject = Prj().GetProjectFullName().IsEmpty();
|
|
wxString path = wxPathOnly( Prj().GetProjectFullName() );
|
|
|
|
wxFileDialog dlg( this, _( "Import Schematic" ), path, wxEmptyString,
|
|
EagleSchematicFileWildcard(), wxFD_OPEN | wxFD_FILE_MUST_EXIST );
|
|
|
|
if( dlg.ShowModal() == wxID_CANCEL )
|
|
return;
|
|
|
|
if( setProject )
|
|
{
|
|
wxFileName projectFn( dlg.GetPath() );
|
|
projectFn.SetExt( ProjectFileExtension );
|
|
Prj().SetProjectFullName( projectFn.GetFullPath() );
|
|
}
|
|
|
|
// For now there is only one import plugin
|
|
importFile( dlg.GetPath(), SCH_IO_MGR::SCH_EAGLE );
|
|
}
|
|
|
|
|
|
bool SCH_EDIT_FRAME::SaveProject()
|
|
{
|
|
wxString msg;
|
|
SCH_SCREEN* screen;
|
|
SCH_SCREENS screens;
|
|
bool success = true;
|
|
bool updateFileType = false;
|
|
|
|
// I want to see it in the debugger, show me the string! Can't do that with wxFileName.
|
|
wxString fileName = Prj().AbsolutePath( g_RootSheet->GetFileName() );
|
|
wxFileName fn = fileName;
|
|
|
|
if( !fn.IsDirWritable() )
|
|
{
|
|
msg = wxString::Format( _( "Directory \"%s\" is not writable." ), fn.GetPath() );
|
|
DisplayError( this, msg );
|
|
return false;
|
|
}
|
|
|
|
// Warn user on potential file overwrite. This can happen on shared sheets.
|
|
wxArrayString overwrittenFiles;
|
|
|
|
for( size_t i = 0; i < screens.GetCount(); i++ )
|
|
{
|
|
screen = screens.GetScreen( i );
|
|
|
|
wxCHECK2( screen, continue );
|
|
|
|
// Convert legacy schematics file name extensions for the new format.
|
|
wxFileName tmpFn = screen->GetFileName();
|
|
|
|
if( tmpFn.GetExt() == KiCadSchematicFileExtension )
|
|
continue;
|
|
|
|
tmpFn.SetExt( KiCadSchematicFileExtension );
|
|
|
|
if( tmpFn.FileExists() )
|
|
overwrittenFiles.Add( tmpFn.GetFullPath() );
|
|
}
|
|
|
|
if( !overwrittenFiles.IsEmpty() )
|
|
{
|
|
for( auto overwrittenFile : overwrittenFiles )
|
|
{
|
|
if( msg.IsEmpty() )
|
|
msg = overwrittenFile;
|
|
else
|
|
msg += "\n" + overwrittenFile;
|
|
}
|
|
|
|
msg = _( "The following files will be overwritten:\n\n" ) + msg;
|
|
|
|
wxRichMessageDialog dlg(
|
|
this,
|
|
_( "Saving the project to the new file format will overwrite existing files." ),
|
|
_( "Project Save Warning" ),
|
|
wxOK | wxCANCEL | wxCANCEL_DEFAULT | wxCENTER | wxICON_EXCLAMATION );
|
|
dlg.ShowDetailedText( msg );
|
|
dlg.SetOKCancelLabels( wxMessageDialog::ButtonLabel( _( "Overwrite Files" ) ),
|
|
wxMessageDialog::ButtonLabel( _( "Abort Project Save" ) ) );
|
|
|
|
if( dlg.ShowModal() == wxID_CANCEL )
|
|
return false;
|
|
}
|
|
|
|
for( size_t i = 0; i < screens.GetCount(); i++ )
|
|
{
|
|
screen = screens.GetScreen( i );
|
|
|
|
wxCHECK2( screen, continue );
|
|
|
|
// Convert legacy schematics file name extensions for the new format.
|
|
wxFileName tmpFn = screen->GetFileName();
|
|
|
|
if( tmpFn.GetExt() != KiCadSchematicFileExtension )
|
|
{
|
|
updateFileType = true;
|
|
tmpFn.SetExt( KiCadSchematicFileExtension );
|
|
|
|
for( auto item : screen->Items().OfType( SCH_SHEET_T ) )
|
|
{
|
|
SCH_SHEET* sheet = static_cast<SCH_SHEET*>( item );
|
|
wxFileName sheetFileName = sheet->GetFileName();
|
|
|
|
if( sheetFileName.GetExt() == KiCadSchematicFileExtension )
|
|
continue;
|
|
|
|
sheetFileName.SetExt( KiCadSchematicFileExtension );
|
|
sheet->SetFileName( sheetFileName.GetFullPath() );
|
|
RefreshItem( sheet );
|
|
}
|
|
|
|
screen->SetFileName( tmpFn.GetFullPath() );
|
|
}
|
|
|
|
success &= SaveEEFile( screens.GetSheet( i ) );
|
|
}
|
|
|
|
if( updateFileType )
|
|
UpdateFileHistory( g_RootSheet->GetScreen()->GetFileName() );
|
|
|
|
// Save the sheet name map to the project file
|
|
wxString configFile = Prj().GetProjectFullName();
|
|
wxConfigBase* config = new wxFileConfig( wxEmptyString, wxEmptyString, configFile );
|
|
int index = 1;
|
|
|
|
config->DeleteGroup( GROUP_SHEET_NAMES );
|
|
config->SetPath( GROUP_SHEET_NAMES );
|
|
|
|
SCH_SHEET_LIST sheetList( g_RootSheet );
|
|
|
|
for( SCH_SHEET_PATH& sheetPath : sheetList )
|
|
{
|
|
SCH_SHEET* sheet = sheetPath.Last();
|
|
config->Write( wxString::Format( "%d", index++ ),
|
|
wxString::Format( "%s:%s", sheet->m_Uuid.AsString(), sheet->GetName() ) );
|
|
}
|
|
|
|
config->Flush();
|
|
delete config;
|
|
|
|
UpdateTitle();
|
|
|
|
return success;
|
|
}
|
|
|
|
|
|
bool SCH_EDIT_FRAME::doAutoSave()
|
|
{
|
|
wxFileName tmpFileName = g_RootSheet->GetFileName();
|
|
wxFileName fn = tmpFileName;
|
|
wxFileName tmp;
|
|
SCH_SCREENS screens;
|
|
|
|
bool autoSaveOk = true;
|
|
|
|
tmp.AssignDir( fn.GetPath() );
|
|
|
|
if( !tmp.IsOk() )
|
|
return false;
|
|
|
|
if( !IsWritable( tmp ) )
|
|
return false;
|
|
|
|
for( size_t i = 0; i < screens.GetCount(); i++ )
|
|
{
|
|
// Only create auto save files for the schematics that have been modified.
|
|
if( !screens.GetScreen( i )->IsSave() )
|
|
continue;
|
|
|
|
tmpFileName = fn = screens.GetScreen( i )->GetFileName();
|
|
|
|
// Auto save file name is the normal file name prefixed with GetAutoSavePrefix().
|
|
fn.SetName( GetAutoSaveFilePrefix() + fn.GetName() );
|
|
|
|
screens.GetScreen( i )->SetFileName( fn.GetFullPath() );
|
|
|
|
if( SaveEEFile( screens.GetSheet( i ), false, NO_BACKUP_FILE ) )
|
|
screens.GetScreen( i )->SetModify();
|
|
else
|
|
autoSaveOk = false;
|
|
|
|
screens.GetScreen( i )->SetFileName( tmpFileName.GetFullPath() );
|
|
}
|
|
|
|
if( autoSaveOk )
|
|
m_autoSaveState = false;
|
|
|
|
return autoSaveOk;
|
|
}
|
|
|
|
|
|
bool SCH_EDIT_FRAME::importFile( const wxString& aFileName, int aFileType )
|
|
{
|
|
wxString projectpath;
|
|
wxFileName newfilename;
|
|
SCH_SHEET_LIST sheetList( g_RootSheet );
|
|
|
|
switch( (SCH_IO_MGR::SCH_FILE_T) aFileType )
|
|
{
|
|
case SCH_IO_MGR::SCH_EAGLE:
|
|
// We insist on caller sending us an absolute path, if it does not, we say it's a bug.
|
|
wxASSERT_MSG( wxFileName( aFileName ).IsAbsolute(),
|
|
wxT( "Import eagle schematic caller didn't send full filename" ) );
|
|
|
|
if( !LockFile( aFileName ) )
|
|
{
|
|
wxString msg = wxString::Format( _( "Schematic file \"%s\" is already open." ),
|
|
aFileName );
|
|
DisplayError( this, msg );
|
|
return false;
|
|
}
|
|
|
|
try
|
|
{
|
|
delete g_RootSheet;
|
|
g_RootSheet = nullptr;
|
|
SCH_PLUGIN::SCH_PLUGIN_RELEASER pi( SCH_IO_MGR::FindPlugin( SCH_IO_MGR::SCH_EAGLE ) );
|
|
g_RootSheet = pi->Load( aFileName, &Kiway() );
|
|
|
|
// Eagle sheets do not use a worksheet frame by default, so set it to an empty one
|
|
WS_DATA_MODEL& pglayout = WS_DATA_MODEL::GetTheInstance();
|
|
pglayout.SetEmptyLayout();
|
|
|
|
BASE_SCREEN::m_PageLayoutDescrFileName = "empty.kicad_wks";
|
|
wxFileName layoutfn( Prj().GetProjectPath(), BASE_SCREEN::m_PageLayoutDescrFileName );
|
|
wxFile layoutfile;
|
|
|
|
if( layoutfile.Create( layoutfn.GetFullPath() ) )
|
|
{
|
|
layoutfile.Write( WS_DATA_MODEL::EmptyLayout() );
|
|
layoutfile.Close();
|
|
}
|
|
|
|
projectpath = Prj().GetProjectPath();
|
|
newfilename.SetPath( projectpath );
|
|
newfilename.SetName( projectpath );
|
|
newfilename.SetExt( LegacySchematicFileExtension );
|
|
|
|
g_CurrentSheet->clear();
|
|
g_CurrentSheet->push_back( g_RootSheet );
|
|
SetScreen( g_CurrentSheet->LastScreen() );
|
|
|
|
g_RootSheet->SetFileName( newfilename.GetFullPath() );
|
|
GetScreen()->SetFileName( newfilename.GetFullPath() );
|
|
GetScreen()->SetModify();
|
|
SaveProjectSettings();
|
|
|
|
UpdateFileHistory( aFileName );
|
|
SCH_SCREENS schematic;
|
|
schematic.UpdateSymbolLinks(); // Update all symbol library links for all sheets.
|
|
|
|
GetScreen()->m_Initialized = true;
|
|
SCH_SCREENS allScreens;
|
|
|
|
for( SCH_SCREEN* screen = allScreens.GetFirst(); screen; screen = allScreens.GetNext() )
|
|
{
|
|
for( auto item : screen->Items().OfType( SCH_COMPONENT_T ) )
|
|
{
|
|
std::vector<wxPoint> pts;
|
|
SCH_COMPONENT* cmp = static_cast<SCH_COMPONENT*>( item );
|
|
|
|
// Update footprint LIB_ID to point to the imported Eagle library
|
|
auto fpField = cmp->GetField( FOOTPRINT );
|
|
|
|
if( !fpField->GetText().IsEmpty() )
|
|
{
|
|
LIB_ID fpId;
|
|
fpId.Parse( fpField->GetText(), LIB_ID::ID_SCH, true );
|
|
fpId.SetLibNickname( newfilename.GetName() );
|
|
fpField->SetText( fpId.Format() );
|
|
}
|
|
}
|
|
}
|
|
// Only perform the dangling end test on root sheet.
|
|
GetScreen()->TestDanglingEnds();
|
|
|
|
GetScreen()->ClearUndoORRedoList( GetScreen()->m_UndoList, 1 );
|
|
|
|
GetScreen()->SetGrid( ID_POPUP_GRID_LEVEL_1000 + m_LastGridSizeId );
|
|
m_toolManager->RunAction( ACTIONS::zoomFitScreen, true );
|
|
SetSheetNumberAndCount();
|
|
SyncView();
|
|
UpdateTitle();
|
|
}
|
|
catch( const IO_ERROR& ioe )
|
|
{
|
|
// Do not leave g_RootSheet == NULL because it is expected to be
|
|
// a valid sheet. Therefore create a dummy empty root sheet and screen.
|
|
CreateScreens();
|
|
m_toolManager->RunAction( ACTIONS::zoomFitScreen, true );
|
|
|
|
wxString msg;
|
|
msg.Printf( _( "Error loading schematic \"%s\".\n%s" ), aFileName, ioe.What() );
|
|
DisplayError( this, msg );
|
|
|
|
msg.Printf( _( "Failed to load \"%s\"" ), aFileName );
|
|
AppendMsgPanel( wxEmptyString, msg, CYAN );
|
|
|
|
return false;
|
|
}
|
|
|
|
return true;
|
|
|
|
default:
|
|
return false;
|
|
}
|
|
}
|
|
|
|
|
|
bool SCH_EDIT_FRAME::AskToSaveChanges()
|
|
{
|
|
SCH_SCREENS screenList;
|
|
|
|
// Save any currently open and modified project files.
|
|
for( SCH_SCREEN* screen = screenList.GetFirst(); screen; screen = screenList.GetNext() )
|
|
{
|
|
if( screen->IsModify() )
|
|
{
|
|
if( !HandleUnsavedChanges( this, _( "The current schematic has been modified. "
|
|
"Save changes?" ),
|
|
[&]()->bool { return SaveProject(); } ) )
|
|
{
|
|
return false;
|
|
}
|
|
}
|
|
}
|
|
|
|
return true;
|
|
}
|