fluke-dmm: 190 series scopemeter support
199B only for now.
This commit is contained in:
parent
4cea0ff7fe
commit
11fb7110f4
|
@ -36,6 +36,7 @@
|
|||
enum {
|
||||
FLUKE_187 = 1,
|
||||
FLUKE_287,
|
||||
FLUKE_190,
|
||||
};
|
||||
|
||||
/* Supported device profiles */
|
||||
|
@ -64,6 +65,11 @@ struct dev_context {
|
|||
int buflen;
|
||||
int64_t cmd_sent_at;
|
||||
int expect_response;
|
||||
int meas_type;
|
||||
int is_relative;
|
||||
int mq;
|
||||
int unit;
|
||||
int mqflags;
|
||||
};
|
||||
|
||||
SR_PRIV int fluke_receive_data(int fd, int revents, void *cb_data);
|
||||
|
|
|
@ -264,12 +264,157 @@ static struct sr_datafeed_analog *handle_qm_28x(const struct sr_dev_inst *sdi,
|
|||
return analog;
|
||||
}
|
||||
|
||||
static void handle_qm_19x_meta(const struct sr_dev_inst *sdi, char **tokens)
|
||||
{
|
||||
struct dev_context *devc;
|
||||
int meas_type, meas_unit, meas_char, i;
|
||||
|
||||
/* Make sure we have 7 valid tokens. */
|
||||
for (i = 0; tokens[i] && i < 7; i++);
|
||||
if (i != 7)
|
||||
return;
|
||||
|
||||
if (strcmp(tokens[1], "1"))
|
||||
/* Invalid measurement. */
|
||||
return;
|
||||
|
||||
if (strcmp(tokens[2], "3"))
|
||||
/* Only interested in input from the meter mode source. */
|
||||
return;
|
||||
|
||||
devc = sdi->priv;
|
||||
|
||||
/* Measurement type 11 == absolute, 19 = relative */
|
||||
meas_type = strtol(tokens[0], NULL, 10);
|
||||
if (meas_type != 11 && meas_type != 19)
|
||||
/* Device is in some mode we don't support. */
|
||||
return;
|
||||
|
||||
/* We might get metadata for absolute and relative mode (if the device
|
||||
* is in relative mode). In that case, relative takes precedence. */
|
||||
if (meas_type == 11 && devc->meas_type == 19)
|
||||
return;
|
||||
|
||||
meas_unit = strtol(tokens[3], NULL, 10);
|
||||
if (meas_unit == 0)
|
||||
/* Device is turned off. Really. */
|
||||
return;
|
||||
meas_char = strtol(tokens[4], NULL, 10);
|
||||
|
||||
devc->mq = devc->unit = -1;
|
||||
devc->mqflags = 0;
|
||||
switch (meas_unit) {
|
||||
case 1:
|
||||
devc->mq = SR_MQ_VOLTAGE;
|
||||
devc->unit = SR_UNIT_VOLT;
|
||||
if (meas_char == 1)
|
||||
devc->mqflags |= SR_MQFLAG_DC;
|
||||
else if (meas_char == 2)
|
||||
devc->mqflags |= SR_MQFLAG_AC;
|
||||
else if (meas_char == 3)
|
||||
devc->mqflags |= SR_MQFLAG_DC | SR_MQFLAG_AC;
|
||||
else if (meas_char == 15)
|
||||
devc->mqflags |= SR_MQFLAG_DIODE;
|
||||
break;
|
||||
case 2:
|
||||
devc->mq = SR_MQ_CURRENT;
|
||||
devc->unit = SR_UNIT_AMPERE;
|
||||
if (meas_char == 1)
|
||||
devc->mqflags |= SR_MQFLAG_DC;
|
||||
else if (meas_char == 2)
|
||||
devc->mqflags |= SR_MQFLAG_AC;
|
||||
else if (meas_char == 3)
|
||||
devc->mqflags |= SR_MQFLAG_DC | SR_MQFLAG_AC;
|
||||
break;
|
||||
case 3:
|
||||
if (meas_char == 1) {
|
||||
devc->mq = SR_MQ_RESISTANCE;
|
||||
devc->unit = SR_UNIT_OHM;
|
||||
} else if (meas_char == 16) {
|
||||
devc->mq = SR_MQ_CONTINUITY;
|
||||
devc->unit = SR_UNIT_BOOLEAN;
|
||||
}
|
||||
break;
|
||||
case 12:
|
||||
devc->mq = SR_MQ_TEMPERATURE;
|
||||
devc->unit = SR_UNIT_CELSIUS;
|
||||
break;
|
||||
case 13:
|
||||
devc->mq = SR_MQ_TEMPERATURE;
|
||||
devc->unit = SR_UNIT_FAHRENHEIT;
|
||||
break;
|
||||
default:
|
||||
sr_dbg("unknown unit: %d", meas_unit);
|
||||
}
|
||||
if (devc->mq == -1 && devc->unit == -1)
|
||||
return;
|
||||
|
||||
/* If we got here, we know how to interpret the measurement. */
|
||||
devc->meas_type = meas_type;
|
||||
if (meas_type == 11)
|
||||
/* Absolute meter reading. */
|
||||
devc->is_relative = FALSE;
|
||||
else if (!strcmp(tokens[0], "19"))
|
||||
/* Relative meter reading. */
|
||||
devc->is_relative = TRUE;
|
||||
|
||||
}
|
||||
|
||||
static void handle_qm_19x_data(const struct sr_dev_inst *sdi, char **tokens)
|
||||
{
|
||||
struct dev_context *devc;
|
||||
struct sr_datafeed_packet packet;
|
||||
struct sr_datafeed_analog analog;
|
||||
float fvalue;
|
||||
char *eptr;
|
||||
|
||||
if (!strcmp(tokens[0], "9.9E+37")) {
|
||||
/* An invalid measurement shows up on the display as "OL", but
|
||||
* comes through like this. Since comparing 38-digit floats
|
||||
* is rather problematic, we'll cut through this here. */
|
||||
fvalue = NAN;
|
||||
} else {
|
||||
fvalue = strtof(tokens[0], &eptr);
|
||||
if (fvalue == 0.0 && eptr == tokens[0]) {
|
||||
sr_err("Invalid float '%s'.", tokens[0]);
|
||||
return;
|
||||
}
|
||||
}
|
||||
|
||||
devc = sdi->priv;
|
||||
if (devc->mq == -1 || devc->unit == -1)
|
||||
/* Don't have valid metadata yet. */
|
||||
return;
|
||||
|
||||
|
||||
if (devc->mq == SR_MQ_RESISTANCE && isnan(fvalue))
|
||||
fvalue = INFINITY;
|
||||
else if (devc->mq == SR_MQ_CONTINUITY) {
|
||||
if (isnan(fvalue))
|
||||
fvalue = 0.0;
|
||||
else
|
||||
fvalue = 1.0;
|
||||
}
|
||||
|
||||
analog.num_samples = 1;
|
||||
analog.data = &fvalue;
|
||||
analog.mq = devc->mq;
|
||||
analog.unit = devc->unit;
|
||||
analog.mqflags = 0;
|
||||
packet.type = SR_DF_ANALOG;
|
||||
packet.payload = &analog;
|
||||
sr_session_send(devc->cb_data, &packet);
|
||||
devc->num_samples++;
|
||||
|
||||
}
|
||||
|
||||
static void handle_line(const struct sr_dev_inst *sdi)
|
||||
{
|
||||
struct dev_context *devc;
|
||||
struct sr_datafeed_packet packet;
|
||||
struct sr_datafeed_analog *analog;
|
||||
char **tokens;
|
||||
int num_tokens, n, i;
|
||||
char cmd[16], **tokens;
|
||||
|
||||
devc = sdi->priv;
|
||||
sr_spew("Received line '%s' (%d).", devc->buf, devc->buflen);
|
||||
|
@ -293,6 +438,29 @@ static void handle_line(const struct sr_dev_inst *sdi)
|
|||
} else if (devc->profile->model == FLUKE_287) {
|
||||
devc->expect_response = FALSE;
|
||||
analog = handle_qm_28x(sdi, tokens);
|
||||
} else if (devc->profile->model == FLUKE_190) {
|
||||
devc->expect_response = FALSE;
|
||||
for (num_tokens = 0; tokens[num_tokens]; num_tokens++);
|
||||
if (num_tokens >= 7) {
|
||||
/* Response to QM: this is a comma-separated list of
|
||||
* fields with metadata about the measurement. This
|
||||
* format can return multiple sets of metadata,
|
||||
* split into sets of 7 tokens each. */
|
||||
devc->meas_type = 0;
|
||||
for (i = 0; i < num_tokens; i += 7)
|
||||
handle_qm_19x_meta(sdi, tokens + i);
|
||||
if (devc->meas_type) {
|
||||
/* Slip the request in now, before the main
|
||||
* timer loop asks for metadata again. */
|
||||
n = sprintf(cmd, "QM %d\r", devc->meas_type);
|
||||
if (serial_write(devc->serial, cmd, n) == -1)
|
||||
sr_err("Unable to send QM (measurement): %s.",
|
||||
strerror(errno));
|
||||
}
|
||||
} else {
|
||||
/* Response to QM <n> measurement request. */
|
||||
handle_qm_19x_data(sdi, tokens);
|
||||
}
|
||||
}
|
||||
}
|
||||
g_strfreev(tokens);
|
||||
|
|
Loading…
Reference in New Issue