README.devices: Cosmetics, consistency fixes, updates.
This commit is contained in:
parent
48d3238e66
commit
1267f128ac
|
@ -51,28 +51,29 @@ The following drivers/devices do not need any firmware upload:
|
|||
|
||||
- agilent-dmm
|
||||
- alsa
|
||||
- bbcgm-m2110
|
||||
- appa-55ii
|
||||
- brymen-dmm
|
||||
- cem-dt-885x
|
||||
- center-3xx
|
||||
- center-3xx (including all subdrivers)
|
||||
- chronovu-la8
|
||||
- colead-slm
|
||||
- demo
|
||||
- fluke-dmm
|
||||
- gmc-mh-1x-2x-rs232
|
||||
- gmc-mh-1x-2x
|
||||
- hameg-hmo
|
||||
- ikalogic-scanalogic2
|
||||
- ikalogic-scanaplus
|
||||
- kecheng-kc-330b
|
||||
- lascar-el-usb
|
||||
- link-mso19
|
||||
- mic-985xx
|
||||
- mic-985xx (including all subdrivers)
|
||||
- norma-dmm
|
||||
- openbench-logic-sniffer
|
||||
- rigol-ds
|
||||
- serial-dmm
|
||||
- serial-dmm (including all subdrivers)
|
||||
- teleinfo
|
||||
- tondaj-sl-814
|
||||
- uni-t-dmm
|
||||
- uni-t-dmm (including all subdrivers)
|
||||
- uni-t-ut32x
|
||||
- victor-dmm
|
||||
- zeroplus-logic-cube
|
||||
|
@ -95,18 +96,20 @@ Example:
|
|||
The following drivers/devices require a serial port specification:
|
||||
|
||||
- agilent-dmm
|
||||
- bbcgm-m2110
|
||||
- appa-55ii
|
||||
- brymen-dmm
|
||||
- cem-dt-885x
|
||||
- center-3xx
|
||||
- center-3xx (including all subdrivers)
|
||||
- colead-slm
|
||||
- fluke-dmm
|
||||
- gmc-mh-1x-2x-rs232
|
||||
- gmc-mh-1x-2x
|
||||
- hameg-hmo
|
||||
- link-mso19
|
||||
- mic-985xx
|
||||
- mic-985xx (including all subdrivers)
|
||||
- norma-dmm
|
||||
- openbench-logic-sniffer
|
||||
- serial-dmm
|
||||
- rigol-ds (for RS232; not required for USBTMC or TCP)
|
||||
- serial-dmm (including all subdrivers)
|
||||
- teleinfo
|
||||
- tondaj-sl-814
|
||||
|
||||
|
@ -122,9 +125,9 @@ The following drivers/devices do not require a serial port specification:
|
|||
- ikalogic-scanaplus
|
||||
- kecheng-kc-330b
|
||||
- lascar-el-usb
|
||||
- rigol-ds
|
||||
- rigol-ds (USBTMC or TCP)
|
||||
- saleae-logic16
|
||||
- uni-t-dmm
|
||||
- uni-t-dmm (including all subdrivers)
|
||||
- uni-t-ut32x
|
||||
- victor-dmm
|
||||
- zeroplus-logic-cube
|
||||
|
@ -136,14 +139,13 @@ Specifiying serial port parameters
|
|||
Every serial device's driver has default serial port parameters like baud
|
||||
rate, number of data bits, stop bits and handshake status. If a device requires
|
||||
different parameters, pass them as option "serialcomm" with the driver name.
|
||||
See libsigrok, docs for function serial_set_paramstr() for complete specs.
|
||||
See libsigrok docs for function serial_set_paramstr() for complete specs.
|
||||
|
||||
Example:
|
||||
|
||||
$ sigrok-cli --driver <somedriver>:conn=<someconn>:serialcomm=9600/7n1/dtr=1
|
||||
|
||||
|
||||
|
||||
Permissions of serial port based devices
|
||||
----------------------------------------
|
||||
|
||||
|
@ -282,12 +284,14 @@ unless a certain action has been performed by the user beforehand. This is
|
|||
usually mentioned in the vendor manual of the respective device, but here's
|
||||
a short list for convenience:
|
||||
|
||||
- bbcgm-m2110: Press button "Start/Reset" on interface panel on top.
|
||||
- BBC Goertz Metrawatt M2110: Briefly press the "Start/Reset" button on the
|
||||
interface panel on top.
|
||||
- Digitek DT4000ZC: Briefly press the "RS232" button.
|
||||
- gmc-mh-1x-2x-rs232: Switch on device with buttons "DATA" pressed.
|
||||
Additionally Metrahit 2x devices must be configured for interface "RS232".
|
||||
- norma-dmm: If the interface does not work (e.g. USB-RS232 converter), switch
|
||||
on device with "FUNC" button pressed to power interface from multimeter.
|
||||
- Gossen Metrawatt Metrahit devices: Power on the device with the "DATA"
|
||||
button pressed. Additionally, Metrahit 2x devices must be configured for
|
||||
interface "RS232".
|
||||
- Norma DM950: If the interface doesn't work (e.g. USB-RS232 converter), power
|
||||
on the device with "FUNC" pressed (to power the interface from the DMM).
|
||||
- PCE PCE-DM32: Briefly press the "RS232" button.
|
||||
- RadioShack 22-812: Press and hold "SELECT" and "RANGE" together.
|
||||
- TekPower TP4000ZC: Briefly press the "RS232" button.
|
||||
|
@ -295,9 +299,8 @@ a short list for convenience:
|
|||
- UNI-T UT325: Briefly press the "SEND" button (as per manual). However, it
|
||||
appears that in practice you don't have to press the button (at least on
|
||||
some versions of the device), simply connect the device via USB.
|
||||
- V&A VA18B: Keep the "Hz/DUTY" key pressed while powering on the device.
|
||||
- Victor 70C: Press the "REL/RS232" button for roughly 1 second.
|
||||
- Victor 86C: Press the "REL/RS232" button for roughly 1 second.
|
||||
- V&A VA18B/VA40B: Keep the "Hz/DUTY" key pressed while powering on the DMM.
|
||||
- Victor 70C/86C: Press the "REL/RS232" button for roughly 1 second.
|
||||
- Voltcraft VC-830: Press the "REL/PC" button for roughly 2 seconds.
|
||||
|
||||
|
||||
|
|
Loading…
Reference in New Issue