README.devices: Cosmetics, consistency fixes, updates.
This commit is contained in:
parent
48d3238e66
commit
1267f128ac
|
@ -51,28 +51,29 @@ The following drivers/devices do not need any firmware upload:
|
||||||
|
|
||||||
- agilent-dmm
|
- agilent-dmm
|
||||||
- alsa
|
- alsa
|
||||||
- bbcgm-m2110
|
- appa-55ii
|
||||||
- brymen-dmm
|
- brymen-dmm
|
||||||
- cem-dt-885x
|
- cem-dt-885x
|
||||||
- center-3xx
|
- center-3xx (including all subdrivers)
|
||||||
- chronovu-la8
|
- chronovu-la8
|
||||||
- colead-slm
|
- colead-slm
|
||||||
- demo
|
- demo
|
||||||
- fluke-dmm
|
- fluke-dmm
|
||||||
- gmc-mh-1x-2x-rs232
|
- gmc-mh-1x-2x
|
||||||
|
- hameg-hmo
|
||||||
- ikalogic-scanalogic2
|
- ikalogic-scanalogic2
|
||||||
- ikalogic-scanaplus
|
- ikalogic-scanaplus
|
||||||
- kecheng-kc-330b
|
- kecheng-kc-330b
|
||||||
- lascar-el-usb
|
- lascar-el-usb
|
||||||
- link-mso19
|
- link-mso19
|
||||||
- mic-985xx
|
- mic-985xx (including all subdrivers)
|
||||||
- norma-dmm
|
- norma-dmm
|
||||||
- openbench-logic-sniffer
|
- openbench-logic-sniffer
|
||||||
- rigol-ds
|
- rigol-ds
|
||||||
- serial-dmm
|
- serial-dmm (including all subdrivers)
|
||||||
- teleinfo
|
- teleinfo
|
||||||
- tondaj-sl-814
|
- tondaj-sl-814
|
||||||
- uni-t-dmm
|
- uni-t-dmm (including all subdrivers)
|
||||||
- uni-t-ut32x
|
- uni-t-ut32x
|
||||||
- victor-dmm
|
- victor-dmm
|
||||||
- zeroplus-logic-cube
|
- zeroplus-logic-cube
|
||||||
|
@ -95,18 +96,20 @@ Example:
|
||||||
The following drivers/devices require a serial port specification:
|
The following drivers/devices require a serial port specification:
|
||||||
|
|
||||||
- agilent-dmm
|
- agilent-dmm
|
||||||
- bbcgm-m2110
|
- appa-55ii
|
||||||
- brymen-dmm
|
- brymen-dmm
|
||||||
- cem-dt-885x
|
- cem-dt-885x
|
||||||
- center-3xx
|
- center-3xx (including all subdrivers)
|
||||||
- colead-slm
|
- colead-slm
|
||||||
- fluke-dmm
|
- fluke-dmm
|
||||||
- gmc-mh-1x-2x-rs232
|
- gmc-mh-1x-2x
|
||||||
|
- hameg-hmo
|
||||||
- link-mso19
|
- link-mso19
|
||||||
- mic-985xx
|
- mic-985xx (including all subdrivers)
|
||||||
- norma-dmm
|
- norma-dmm
|
||||||
- openbench-logic-sniffer
|
- openbench-logic-sniffer
|
||||||
- serial-dmm
|
- rigol-ds (for RS232; not required for USBTMC or TCP)
|
||||||
|
- serial-dmm (including all subdrivers)
|
||||||
- teleinfo
|
- teleinfo
|
||||||
- tondaj-sl-814
|
- tondaj-sl-814
|
||||||
|
|
||||||
|
@ -122,9 +125,9 @@ The following drivers/devices do not require a serial port specification:
|
||||||
- ikalogic-scanaplus
|
- ikalogic-scanaplus
|
||||||
- kecheng-kc-330b
|
- kecheng-kc-330b
|
||||||
- lascar-el-usb
|
- lascar-el-usb
|
||||||
- rigol-ds
|
- rigol-ds (USBTMC or TCP)
|
||||||
- saleae-logic16
|
- saleae-logic16
|
||||||
- uni-t-dmm
|
- uni-t-dmm (including all subdrivers)
|
||||||
- uni-t-ut32x
|
- uni-t-ut32x
|
||||||
- victor-dmm
|
- victor-dmm
|
||||||
- zeroplus-logic-cube
|
- zeroplus-logic-cube
|
||||||
|
@ -136,14 +139,13 @@ Specifiying serial port parameters
|
||||||
Every serial device's driver has default serial port parameters like baud
|
Every serial device's driver has default serial port parameters like baud
|
||||||
rate, number of data bits, stop bits and handshake status. If a device requires
|
rate, number of data bits, stop bits and handshake status. If a device requires
|
||||||
different parameters, pass them as option "serialcomm" with the driver name.
|
different parameters, pass them as option "serialcomm" with the driver name.
|
||||||
See libsigrok, docs for function serial_set_paramstr() for complete specs.
|
See libsigrok docs for function serial_set_paramstr() for complete specs.
|
||||||
|
|
||||||
Example:
|
Example:
|
||||||
|
|
||||||
$ sigrok-cli --driver <somedriver>:conn=<someconn>:serialcomm=9600/7n1/dtr=1
|
$ sigrok-cli --driver <somedriver>:conn=<someconn>:serialcomm=9600/7n1/dtr=1
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
Permissions of serial port based devices
|
Permissions of serial port based devices
|
||||||
----------------------------------------
|
----------------------------------------
|
||||||
|
|
||||||
|
@ -282,12 +284,14 @@ unless a certain action has been performed by the user beforehand. This is
|
||||||
usually mentioned in the vendor manual of the respective device, but here's
|
usually mentioned in the vendor manual of the respective device, but here's
|
||||||
a short list for convenience:
|
a short list for convenience:
|
||||||
|
|
||||||
- bbcgm-m2110: Press button "Start/Reset" on interface panel on top.
|
- BBC Goertz Metrawatt M2110: Briefly press the "Start/Reset" button on the
|
||||||
|
interface panel on top.
|
||||||
- Digitek DT4000ZC: Briefly press the "RS232" button.
|
- Digitek DT4000ZC: Briefly press the "RS232" button.
|
||||||
- gmc-mh-1x-2x-rs232: Switch on device with buttons "DATA" pressed.
|
- Gossen Metrawatt Metrahit devices: Power on the device with the "DATA"
|
||||||
Additionally Metrahit 2x devices must be configured for interface "RS232".
|
button pressed. Additionally, Metrahit 2x devices must be configured for
|
||||||
- norma-dmm: If the interface does not work (e.g. USB-RS232 converter), switch
|
interface "RS232".
|
||||||
on device with "FUNC" button pressed to power interface from multimeter.
|
- Norma DM950: If the interface doesn't work (e.g. USB-RS232 converter), power
|
||||||
|
on the device with "FUNC" pressed (to power the interface from the DMM).
|
||||||
- PCE PCE-DM32: Briefly press the "RS232" button.
|
- PCE PCE-DM32: Briefly press the "RS232" button.
|
||||||
- RadioShack 22-812: Press and hold "SELECT" and "RANGE" together.
|
- RadioShack 22-812: Press and hold "SELECT" and "RANGE" together.
|
||||||
- TekPower TP4000ZC: Briefly press the "RS232" button.
|
- TekPower TP4000ZC: Briefly press the "RS232" button.
|
||||||
|
@ -295,9 +299,8 @@ a short list for convenience:
|
||||||
- UNI-T UT325: Briefly press the "SEND" button (as per manual). However, it
|
- UNI-T UT325: Briefly press the "SEND" button (as per manual). However, it
|
||||||
appears that in practice you don't have to press the button (at least on
|
appears that in practice you don't have to press the button (at least on
|
||||||
some versions of the device), simply connect the device via USB.
|
some versions of the device), simply connect the device via USB.
|
||||||
- V&A VA18B: Keep the "Hz/DUTY" key pressed while powering on the device.
|
- V&A VA18B/VA40B: Keep the "Hz/DUTY" key pressed while powering on the DMM.
|
||||||
- Victor 70C: Press the "REL/RS232" button for roughly 1 second.
|
- Victor 70C/86C: Press the "REL/RS232" button for roughly 1 second.
|
||||||
- Victor 86C: Press the "REL/RS232" button for roughly 1 second.
|
|
||||||
- Voltcraft VC-830: Press the "REL/PC" button for roughly 2 seconds.
|
- Voltcraft VC-830: Press the "REL/PC" button for roughly 2 seconds.
|
||||||
|
|
||||||
|
|
||||||
|
|
Loading…
Reference in New Issue