README.devices: Cosmetics, consistency fixes, updates.

This commit is contained in:
Uwe Hermann 2014-01-04 00:18:29 +01:00
parent 48d3238e66
commit 1267f128ac
1 changed files with 26 additions and 23 deletions

View File

@ -51,28 +51,29 @@ The following drivers/devices do not need any firmware upload:
- agilent-dmm - agilent-dmm
- alsa - alsa
- bbcgm-m2110 - appa-55ii
- brymen-dmm - brymen-dmm
- cem-dt-885x - cem-dt-885x
- center-3xx - center-3xx (including all subdrivers)
- chronovu-la8 - chronovu-la8
- colead-slm - colead-slm
- demo - demo
- fluke-dmm - fluke-dmm
- gmc-mh-1x-2x-rs232 - gmc-mh-1x-2x
- hameg-hmo
- ikalogic-scanalogic2 - ikalogic-scanalogic2
- ikalogic-scanaplus - ikalogic-scanaplus
- kecheng-kc-330b - kecheng-kc-330b
- lascar-el-usb - lascar-el-usb
- link-mso19 - link-mso19
- mic-985xx - mic-985xx (including all subdrivers)
- norma-dmm - norma-dmm
- openbench-logic-sniffer - openbench-logic-sniffer
- rigol-ds - rigol-ds
- serial-dmm - serial-dmm (including all subdrivers)
- teleinfo - teleinfo
- tondaj-sl-814 - tondaj-sl-814
- uni-t-dmm - uni-t-dmm (including all subdrivers)
- uni-t-ut32x - uni-t-ut32x
- victor-dmm - victor-dmm
- zeroplus-logic-cube - zeroplus-logic-cube
@ -95,18 +96,20 @@ Example:
The following drivers/devices require a serial port specification: The following drivers/devices require a serial port specification:
- agilent-dmm - agilent-dmm
- bbcgm-m2110 - appa-55ii
- brymen-dmm - brymen-dmm
- cem-dt-885x - cem-dt-885x
- center-3xx - center-3xx (including all subdrivers)
- colead-slm - colead-slm
- fluke-dmm - fluke-dmm
- gmc-mh-1x-2x-rs232 - gmc-mh-1x-2x
- hameg-hmo
- link-mso19 - link-mso19
- mic-985xx - mic-985xx (including all subdrivers)
- norma-dmm - norma-dmm
- openbench-logic-sniffer - openbench-logic-sniffer
- serial-dmm - rigol-ds (for RS232; not required for USBTMC or TCP)
- serial-dmm (including all subdrivers)
- teleinfo - teleinfo
- tondaj-sl-814 - tondaj-sl-814
@ -122,9 +125,9 @@ The following drivers/devices do not require a serial port specification:
- ikalogic-scanaplus - ikalogic-scanaplus
- kecheng-kc-330b - kecheng-kc-330b
- lascar-el-usb - lascar-el-usb
- rigol-ds - rigol-ds (USBTMC or TCP)
- saleae-logic16 - saleae-logic16
- uni-t-dmm - uni-t-dmm (including all subdrivers)
- uni-t-ut32x - uni-t-ut32x
- victor-dmm - victor-dmm
- zeroplus-logic-cube - zeroplus-logic-cube
@ -136,14 +139,13 @@ Specifiying serial port parameters
Every serial device's driver has default serial port parameters like baud Every serial device's driver has default serial port parameters like baud
rate, number of data bits, stop bits and handshake status. If a device requires rate, number of data bits, stop bits and handshake status. If a device requires
different parameters, pass them as option "serialcomm" with the driver name. different parameters, pass them as option "serialcomm" with the driver name.
See libsigrok, docs for function serial_set_paramstr() for complete specs. See libsigrok docs for function serial_set_paramstr() for complete specs.
Example: Example:
$ sigrok-cli --driver <somedriver>:conn=<someconn>:serialcomm=9600/7n1/dtr=1 $ sigrok-cli --driver <somedriver>:conn=<someconn>:serialcomm=9600/7n1/dtr=1
Permissions of serial port based devices Permissions of serial port based devices
---------------------------------------- ----------------------------------------
@ -282,12 +284,14 @@ unless a certain action has been performed by the user beforehand. This is
usually mentioned in the vendor manual of the respective device, but here's usually mentioned in the vendor manual of the respective device, but here's
a short list for convenience: a short list for convenience:
- bbcgm-m2110: Press button "Start/Reset" on interface panel on top. - BBC Goertz Metrawatt M2110: Briefly press the "Start/Reset" button on the
interface panel on top.
- Digitek DT4000ZC: Briefly press the "RS232" button. - Digitek DT4000ZC: Briefly press the "RS232" button.
- gmc-mh-1x-2x-rs232: Switch on device with buttons "DATA" pressed. - Gossen Metrawatt Metrahit devices: Power on the device with the "DATA"
Additionally Metrahit 2x devices must be configured for interface "RS232". button pressed. Additionally, Metrahit 2x devices must be configured for
- norma-dmm: If the interface does not work (e.g. USB-RS232 converter), switch interface "RS232".
on device with "FUNC" button pressed to power interface from multimeter. - Norma DM950: If the interface doesn't work (e.g. USB-RS232 converter), power
on the device with "FUNC" pressed (to power the interface from the DMM).
- PCE PCE-DM32: Briefly press the "RS232" button. - PCE PCE-DM32: Briefly press the "RS232" button.
- RadioShack 22-812: Press and hold "SELECT" and "RANGE" together. - RadioShack 22-812: Press and hold "SELECT" and "RANGE" together.
- TekPower TP4000ZC: Briefly press the "RS232" button. - TekPower TP4000ZC: Briefly press the "RS232" button.
@ -295,9 +299,8 @@ a short list for convenience:
- UNI-T UT325: Briefly press the "SEND" button (as per manual). However, it - UNI-T UT325: Briefly press the "SEND" button (as per manual). However, it
appears that in practice you don't have to press the button (at least on appears that in practice you don't have to press the button (at least on
some versions of the device), simply connect the device via USB. some versions of the device), simply connect the device via USB.
- V&A VA18B: Keep the "Hz/DUTY" key pressed while powering on the device. - V&A VA18B/VA40B: Keep the "Hz/DUTY" key pressed while powering on the DMM.
- Victor 70C: Press the "REL/RS232" button for roughly 1 second. - Victor 70C/86C: Press the "REL/RS232" button for roughly 1 second.
- Victor 86C: Press the "REL/RS232" button for roughly 1 second.
- Voltcraft VC-830: Press the "REL/PC" button for roughly 2 seconds. - Voltcraft VC-830: Press the "REL/PC" button for roughly 2 seconds.