agilent_dmm: Split generic part of recv_log_u128x() to recv_log().

This commit is contained in:
Aurelien Jacobs 2017-01-16 11:47:42 +01:00
parent 29bdeeb549
commit 1af3f40eec
1 changed files with 13 additions and 5 deletions

View File

@ -772,11 +772,10 @@ static int send_log(const struct sr_dev_inst *sdi)
source[devc->data_source - 1], devc->cur_sample);
}
static int recv_log_u128x(const struct sr_dev_inst *sdi, GMatchInfo *match)
static int recv_log(const struct sr_dev_inst *sdi, GMatchInfo *match,
const int mqs[], const int units[], const int exponents[],
unsigned int num_functions)
{
static const int mqs[] = { SR_MQ_VOLTAGE, SR_MQ_VOLTAGE, SR_MQ_CURRENT, SR_MQ_CURRENT, SR_MQ_RESISTANCE, SR_MQ_VOLTAGE, SR_MQ_TEMPERATURE, SR_MQ_CAPACITANCE, SR_MQ_FREQUENCY, SR_MQ_DUTY_CYCLE, SR_MQ_PULSE_WIDTH, SR_MQ_VOLTAGE, SR_MQ_CURRENT, SR_MQ_CONDUCTANCE };
static const int units[] = { SR_UNIT_VOLT, SR_UNIT_VOLT, SR_UNIT_AMPERE, SR_UNIT_AMPERE, SR_UNIT_OHM, SR_UNIT_VOLT, SR_UNIT_CELSIUS, SR_UNIT_FARAD, SR_UNIT_HERTZ, SR_UNIT_PERCENTAGE, SR_UNIT_SECOND, SR_UNIT_DECIBEL_MW, SR_UNIT_PERCENTAGE, SR_UNIT_SIEMENS };
static const int exponents[] = { -6, -4, -9, -4, -3, -4, -1, -12, -3, -3, -6, -3, -2, -11 };
struct dev_context *devc;
struct sr_datafeed_packet packet;
struct sr_datafeed_analog analog;
@ -794,7 +793,7 @@ static int recv_log_u128x(const struct sr_dev_inst *sdi, GMatchInfo *match)
devc = sdi->priv;
mstr = g_match_info_fetch(match, 2);
if (sr_atoi(mstr, (int*)&function) != SR_OK || function >= ARRAY_SIZE(mqs)) {
if (sr_atoi(mstr, (int*)&function) != SR_OK || function >= num_functions) {
g_free(mstr);
sr_dbg("Invalid function.");
return SR_ERR;
@ -860,6 +859,15 @@ static int recv_log_u128x(const struct sr_dev_inst *sdi, GMatchInfo *match)
return JOB_LOG;
}
static int recv_log_u128x(const struct sr_dev_inst *sdi, GMatchInfo *match)
{
static const int mqs[] = { SR_MQ_VOLTAGE, SR_MQ_VOLTAGE, SR_MQ_CURRENT, SR_MQ_CURRENT, SR_MQ_RESISTANCE, SR_MQ_VOLTAGE, SR_MQ_TEMPERATURE, SR_MQ_CAPACITANCE, SR_MQ_FREQUENCY, SR_MQ_DUTY_CYCLE, SR_MQ_PULSE_WIDTH, SR_MQ_VOLTAGE, SR_MQ_CURRENT, SR_MQ_CONDUCTANCE };
static const int units[] = { SR_UNIT_VOLT, SR_UNIT_VOLT, SR_UNIT_AMPERE, SR_UNIT_AMPERE, SR_UNIT_OHM, SR_UNIT_VOLT, SR_UNIT_CELSIUS, SR_UNIT_FARAD, SR_UNIT_HERTZ, SR_UNIT_PERCENTAGE, SR_UNIT_SECOND, SR_UNIT_DECIBEL_MW, SR_UNIT_PERCENTAGE, SR_UNIT_SIEMENS };
static const int exponents[] = { -6, -4, -9, -4, -3, -4, -1, -12, -3, -3, -6, -3, -2, -11 };
return recv_log(sdi, match, mqs, units, exponents, ARRAY_SIZE(mqs));
}
/* This comes in whenever the rotary switch is changed to a new position.
* We could use it to determine the major measurement mode, but we already
* have the output of CONF? for that, which is more detailed. However