doc: update README.devices for GWInstek VCP (CP210x in disguise)
Reference the vendor's Windows specific "driver" download for the CP210x chip with a non-default VID:PID. Provide an example how to assign the Linux driver to that device (interactive, no udev rule).
This commit is contained in:
parent
f91c6940ab
commit
24a953382c
|
@ -275,6 +275,20 @@ rules shipped by the system will be broken.
|
|||
Please consult the udev docs for details.
|
||||
|
||||
|
||||
Non-default drivers for commodity chips
|
||||
---------------------------------------
|
||||
|
||||
Some vendors include common USB chips in their products yet assign device
|
||||
specific VID:PID pairs. Which results in the necessity for extra steps
|
||||
before the serial port can be used:
|
||||
|
||||
- GW Instek VCP, found in GDM-8000 and probably other meters: Install the
|
||||
vendors Windows driver to get access to a COM port. Or force the driver
|
||||
assignment on Linux:
|
||||
# modprobe cp210x
|
||||
# echo 2184 0030 > /sys/bus/usb-serial/drivers/cp210x/new_id
|
||||
|
||||
|
||||
Cypress FX2 based devices
|
||||
-------------------------
|
||||
|
||||
|
@ -391,6 +405,8 @@ a short list for convenience:
|
|||
be configured to the same baud rate as the host (default 9600).
|
||||
Multimeter and interface must be configured to the same address.
|
||||
- GW Instek GDM-397: Press the "REL/RS232C (USB)" button for roughly 1 second.
|
||||
- GW Instek VCP: See the discussion on manual driver assignment to common
|
||||
USB to UART chips with non-default USB identification.
|
||||
- MASTECH MS6514: Press the "Setup/PC-Link" button for roughly 3 seconds.
|
||||
- Metrix MX56C: Press the PRINT button to have the meter send acquisition
|
||||
data via IR. Hold the PRINT button to adjust the meter's transmission
|
||||
|
|