dmm/eev121gw: add missing scale items for sub display in power modes
Complete the voltage and current scale items for the sub display which were incomplete for VA, mVA, and uVA power measurement modes before.
This commit is contained in:
parent
59cae77e28
commit
39ea7b7d39
|
@ -559,19 +559,27 @@ static const struct mode_range_items mode_ranges_diode_sub = {
|
|||
},
|
||||
};
|
||||
|
||||
/* TODO: Complete the list of ranges. Only tested with low voltages so far. */
|
||||
static const struct mode_range_items mode_ranges_volts_sub = {
|
||||
.range_count = 5,
|
||||
.ranges = {
|
||||
[3] = { .desc = "50.000V", .digits = 3, .factor = 3, },
|
||||
[4] = { .desc = "5.0000V", .digits = 4, .factor = 4, },
|
||||
},
|
||||
};
|
||||
|
||||
/* TODO: Complete the list of ranges. Only tested with low voltages so far. */
|
||||
static const struct mode_range_items mode_ranges_mamps_sub = {
|
||||
.range_count = 3,
|
||||
.range_count = 5,
|
||||
.ranges = {
|
||||
[2] = { .desc = "500.00mA", .digits = 5, .factor = 5, },
|
||||
[3] = { .desc = "50.000mA", .digits = 6, .factor = 6, },
|
||||
[4] = { .desc = "5.0000mA", .digits = 7, .factor = 7, },
|
||||
},
|
||||
};
|
||||
|
||||
static const struct mode_range_items mode_ranges_uamps_sub = {
|
||||
.range_count = 5,
|
||||
.ranges = {
|
||||
[4] = { .desc = "5.0000mA", .digits = 7, .factor = 7, },
|
||||
},
|
||||
};
|
||||
|
||||
|
@ -580,6 +588,10 @@ static const struct mode_range_items *mode_ranges_sub[] = {
|
|||
[MODE_AC_V] = &mode_ranges_volts_sub,
|
||||
[MODE_DC_A] = &mode_ranges_mamps_sub,
|
||||
[MODE_AC_A] = &mode_ranges_mamps_sub,
|
||||
[MODE_DC_MA] = &mode_ranges_mamps_sub,
|
||||
[MODE_AC_MA] = &mode_ranges_mamps_sub,
|
||||
[MODE_DC_UA] = &mode_ranges_uamps_sub,
|
||||
[MODE_AC_UA] = &mode_ranges_uamps_sub,
|
||||
[MODE_FREQ] = &mode_ranges_freq_sub,
|
||||
[MODE_DIODE] = &mode_ranges_diode_sub,
|
||||
[MODE_SUB_TEMPC] = &mode_ranges_temp_sub,
|
||||
|
|