scpi-pps: Add SR_CONF_REGULATION for HP 66xxB power supplies.

This commit is contained in:
Frank Stettner 2019-04-09 15:29:30 +02:00 committed by Uwe Hermann
parent 5e7377f4c7
commit 43ff1110fb
3 changed files with 39 additions and 13 deletions

View File

@ -956,6 +956,8 @@ enum sr_configkey {
* Channel regulation
* get: "CV", "CC" or "UR", denoting constant voltage, constant current
* or unregulated.
* "CC-" denotes a power supply in current sink mode (e.g. HP 66xxB).
* "" is used when there is no regulation, e.g. the output is disabled.
*/
SR_CONF_REGULATION,

View File

@ -313,6 +313,7 @@ static int config_get(uint32_t key, GVariant **data,
char *channel_group_name;
int cmd, ret;
const char *s;
int oper_cond;
if (!sdi)
return SR_ERR_ARG;
@ -419,24 +420,45 @@ static int config_get(uint32_t key, GVariant **data,
channel_group_cmd, channel_group_name, data, gvtype, cmd);
g_free(channel_group_name);
/*
* Handle special cases
*/
if (cmd == SCPI_CMD_GET_OUTPUT_REGULATION) {
/*
* The Rigol DP800 series return CV/CC/UR, Philips PM2800
* return VOLT/CURR. We always return a GVariant string in
* the Rigol notation.
*/
s = g_variant_get_string(*data, NULL);
if (!strcmp(s, "VOLT")) {
if (devc->device->dialect == SCPI_DIALECT_PHILIPS) {
/*
* The Philips PM2800 series returns VOLT/CURR. We always return
* a GVariant string in the Rigol notation (CV/CC/UR).
*/
s = g_variant_get_string(*data, NULL);
if (!g_strcmp0(s, "VOLT")) {
g_variant_unref(*data);
*data = g_variant_new_string("CV");
} else if (!g_strcmp0(s, "CURR")) {
g_variant_unref(*data);
*data = g_variant_new_string("CC");
}
}
if (devc->device->dialect == SCPI_DIALECT_HP_66XXB) {
/* Evaluate Operational Status Register from a HP 66xxB. */
s = g_variant_get_string(*data, NULL);
sr_atoi(s, &oper_cond);
g_variant_unref(*data);
*data = g_variant_new_string("CV");
} else if (!strcmp(s, "CURR")) {
g_variant_unref(*data);
*data = g_variant_new_string("CC");
if (oper_cond & (1 << 8))
*data = g_variant_new_string("CV");
else if (oper_cond & (1 << 10))
*data = g_variant_new_string("CC");
else if (oper_cond & (1 << 11))
*data = g_variant_new_string("CC-");
else
*data = g_variant_new_string("UR");
}
s = g_variant_get_string(*data, NULL);
if (strcmp(s, "CV") && strcmp(s, "CC") && strcmp(s, "UR")) {
sr_dbg("Unknown response to SCPI_CMD_GET_OUTPUT_REGULATION: %s", s);
if (g_strcmp0(s, "CV") && g_strcmp0(s, "CC") &&
g_strcmp0(s, "CC-") && g_strcmp0(s, "UR")) {
sr_err("Unknown response to SCPI_CMD_GET_OUTPUT_REGULATION: %s", s);
ret = SR_ERR_DATA;
}
}

View File

@ -460,6 +460,7 @@ static const uint32_t hp_6630b_devopts_cg[] = {
SR_CONF_CURRENT_LIMIT | SR_CONF_GET | SR_CONF_SET | SR_CONF_LIST,
SR_CONF_OVER_VOLTAGE_PROTECTION_THRESHOLD | SR_CONF_GET | SR_CONF_SET | SR_CONF_LIST,
SR_CONF_OVER_CURRENT_PROTECTION_ENABLED | SR_CONF_GET | SR_CONF_SET,
SR_CONF_REGULATION | SR_CONF_GET,
};
static const struct channel_spec hp_6633a_ch[] = {
@ -520,6 +521,7 @@ static const struct scpi_command hp_6630b_cmd[] = {
{ SCPI_CMD_SET_OVER_CURRENT_PROTECTION_DISABLE, ":CURR:PROT:STAT 0" },
{ SCPI_CMD_GET_OVER_VOLTAGE_PROTECTION_THRESHOLD, ":VOLT:PROT?" },
{ SCPI_CMD_SET_OVER_VOLTAGE_PROTECTION_THRESHOLD, ":VOLT:PROT %.6f" },
{ SCPI_CMD_GET_OUTPUT_REGULATION, "STAT:OPER:COND?" },
ALL_ZERO
};