scpi-pps: Add support for Owon P4000 series.
Tested on P4603 firmware version 1.6.0.
This commit is contained in:
parent
389acdd991
commit
5433907ed9
|
@ -836,6 +836,53 @@ static int hp_6630b_update_status(const struct sr_dev_inst *sdi)
|
|||
return SR_OK;
|
||||
}
|
||||
|
||||
/* Owon P4000 series */
|
||||
static const uint32_t owon_p4000_devopts[] = {
|
||||
SR_CONF_CONTINUOUS,
|
||||
SR_CONF_LIMIT_SAMPLES | SR_CONF_GET | SR_CONF_SET,
|
||||
SR_CONF_LIMIT_MSEC | SR_CONF_GET | SR_CONF_SET
|
||||
};
|
||||
|
||||
static const uint32_t owon_p4000_devopts_cg[] = {
|
||||
SR_CONF_ENABLED | SR_CONF_GET | SR_CONF_SET,
|
||||
SR_CONF_VOLTAGE | SR_CONF_GET,
|
||||
SR_CONF_VOLTAGE_TARGET | SR_CONF_GET | SR_CONF_SET | SR_CONF_LIST,
|
||||
SR_CONF_CURRENT | SR_CONF_GET,
|
||||
SR_CONF_CURRENT_LIMIT | SR_CONF_GET | SR_CONF_SET | SR_CONF_LIST,
|
||||
SR_CONF_OVER_VOLTAGE_PROTECTION_THRESHOLD | SR_CONF_GET | SR_CONF_SET,
|
||||
SR_CONF_OVER_CURRENT_PROTECTION_THRESHOLD | SR_CONF_GET | SR_CONF_SET,
|
||||
};
|
||||
|
||||
static const struct channel_spec owon_p4603_ch[] = {
|
||||
{ "1", { 0.01, 60, 0.001, 3, 3 }, { 0.001, 3, 0.001, 3, 3 }, { 0, 180, 0, 3, 3 }, FREQ_DC_ONLY, { 0.01, 61, 0.001}, { 0.001, 3.1, 0.001} },
|
||||
};
|
||||
|
||||
static const struct channel_spec owon_p4305_ch[] = {
|
||||
{ "1", { 0.01, 30, 0.001, 3, 3 }, { 0.001, 5, 0.001, 3, 3 }, { 0, 180, 0, 3, 3 }, FREQ_DC_ONLY, { 0.01, 31, 0.001}, { 0.001, 3.1, 0.001} },
|
||||
};
|
||||
|
||||
static const struct channel_group_spec owon_p4000_cg[] = {
|
||||
{ "1", CH_IDX(0), PPS_OVP | PPS_OCP, SR_MQFLAG_DC },
|
||||
};
|
||||
|
||||
static const struct scpi_command owon_p4000_cmd[] = {
|
||||
{ SCPI_CMD_GET_MEAS_VOLTAGE, "MEAS:VOLT?" },
|
||||
{ SCPI_CMD_GET_MEAS_CURRENT, "MEAS:CURR?" },
|
||||
{ SCPI_CMD_GET_MEAS_POWER, "MEAS:POW?" },
|
||||
{ SCPI_CMD_GET_VOLTAGE_TARGET, "VOLT?" },
|
||||
{ SCPI_CMD_SET_VOLTAGE_TARGET, "VOLT %.6f" },
|
||||
{ SCPI_CMD_GET_CURRENT_LIMIT, "CURR?" },
|
||||
{ SCPI_CMD_SET_CURRENT_LIMIT, "CURR %.6f" },
|
||||
{ SCPI_CMD_GET_OUTPUT_ENABLED, "OUTP?" },
|
||||
{ SCPI_CMD_SET_OUTPUT_ENABLE, "OUTP 1" },
|
||||
{ SCPI_CMD_SET_OUTPUT_DISABLE, "OUTP 0" },
|
||||
{ SCPI_CMD_GET_OVER_VOLTAGE_PROTECTION_THRESHOLD, "VOLT:LIM?" },
|
||||
{ SCPI_CMD_SET_OVER_VOLTAGE_PROTECTION_THRESHOLD, "VOLT:LIM %.6f" },
|
||||
{ SCPI_CMD_GET_OVER_CURRENT_PROTECTION_THRESHOLD, "CURR:LIM?" },
|
||||
{ SCPI_CMD_SET_OVER_CURRENT_PROTECTION_THRESHOLD, "CURR:LIM %.6f" },
|
||||
ALL_ZERO
|
||||
};
|
||||
|
||||
/* Philips/Fluke PM2800 series */
|
||||
static const uint32_t philips_pm2800_devopts[] = {
|
||||
SR_CONF_CONTINUOUS,
|
||||
|
@ -1403,6 +1450,28 @@ SR_PRIV const struct scpi_pps pps_profiles[] = {
|
|||
.update_status = NULL,
|
||||
},
|
||||
|
||||
/* Owon P4000 series */
|
||||
{ "OWON", "^P4305$", SCPI_DIALECT_UNKNOWN, 0,
|
||||
ARRAY_AND_SIZE(owon_p4000_devopts),
|
||||
ARRAY_AND_SIZE(owon_p4000_devopts_cg),
|
||||
ARRAY_AND_SIZE(owon_p4305_ch),
|
||||
ARRAY_AND_SIZE(owon_p4000_cg),
|
||||
owon_p4000_cmd,
|
||||
.probe_channels = NULL,
|
||||
.init_acquisition = NULL,
|
||||
.update_status = NULL,
|
||||
},
|
||||
{ "OWON", "^P4603$", SCPI_DIALECT_UNKNOWN, 0,
|
||||
ARRAY_AND_SIZE(owon_p4000_devopts),
|
||||
ARRAY_AND_SIZE(owon_p4000_devopts_cg),
|
||||
ARRAY_AND_SIZE(owon_p4603_ch),
|
||||
ARRAY_AND_SIZE(owon_p4000_cg),
|
||||
owon_p4000_cmd,
|
||||
.probe_channels = NULL,
|
||||
.init_acquisition = NULL,
|
||||
.update_status = NULL,
|
||||
},
|
||||
|
||||
/* Philips/Fluke PM2800 series */
|
||||
{ "Philips", "^PM28[13][123]/[01234]{1,2}$", SCPI_DIALECT_PHILIPS, 0,
|
||||
ARRAY_AND_SIZE(philips_pm2800_devopts),
|
||||
|
|
Loading…
Reference in New Issue