Sigma: Limit number of edge triggers to 1.
Actually, Sigma supports 2 rising/falling triggers, but they are ORed and the current trigger syntax does not permit ORed triggers.
This commit is contained in:
parent
31facdd3c5
commit
98b8cbc17e
|
@ -643,8 +643,13 @@ static int configure_probes(struct sigrok_device_instance *sdi, GSList *probes)
|
|||
++trigger_set;
|
||||
}
|
||||
|
||||
if (trigger_set > 2) {
|
||||
g_warning("Asix Sigma only supports 2 rising/"
|
||||
/*
|
||||
* Actually, Sigma supports 2 rising/falling triggers,
|
||||
* but they are ORed and the current trigger syntax
|
||||
* does not permit ORed triggers.
|
||||
*/
|
||||
if (trigger_set > 1) {
|
||||
g_warning("Asix Sigma only supports 1 rising/"
|
||||
"falling triggers.");
|
||||
return SIGROK_ERR;
|
||||
}
|
||||
|
|
Loading…