uni-t-ut181a: comment on how to start a recording
The meter allows remote controlled start of recordings, but requires a few parameters where it's uncertain how to most appropriately get these by means of SR_CONF_* keys. Introduce SR_CONF_SET support for SR_CONF_DATALOG to raise awareness, but leave the implementation empty for now. Leave a TODO comment which discusses the meter's commands that one might want to use from here.
This commit is contained in:
parent
ebc5110989
commit
cbfaf5e073
|
@ -37,7 +37,8 @@ static const uint32_t devopts[] = {
|
||||||
SR_CONF_LIMIT_SAMPLES | SR_CONF_GET | SR_CONF_SET,
|
SR_CONF_LIMIT_SAMPLES | SR_CONF_GET | SR_CONF_SET,
|
||||||
SR_CONF_LIMIT_MSEC | SR_CONF_GET | SR_CONF_SET,
|
SR_CONF_LIMIT_MSEC | SR_CONF_GET | SR_CONF_SET,
|
||||||
SR_CONF_DATA_SOURCE | SR_CONF_GET | SR_CONF_SET | SR_CONF_LIST,
|
SR_CONF_DATA_SOURCE | SR_CONF_GET | SR_CONF_SET | SR_CONF_LIST,
|
||||||
SR_CONF_DATALOG | SR_CONF_GET,
|
SR_CONF_DATALOG | SR_CONF_GET | SR_CONF_SET,
|
||||||
|
/* TODO SR_CONF_DATALOG is bool only, how to setup interval/duration? */
|
||||||
SR_CONF_MEASURED_QUANTITY | SR_CONF_GET | SR_CONF_SET | SR_CONF_LIST,
|
SR_CONF_MEASURED_QUANTITY | SR_CONF_GET | SR_CONF_SET | SR_CONF_LIST,
|
||||||
SR_CONF_RANGE | SR_CONF_GET | SR_CONF_SET | SR_CONF_LIST,
|
SR_CONF_RANGE | SR_CONF_GET | SR_CONF_SET | SR_CONF_LIST,
|
||||||
};
|
};
|
||||||
|
@ -335,6 +336,7 @@ static int config_set(uint32_t key, GVariant *data,
|
||||||
{
|
{
|
||||||
struct dev_context *devc;
|
struct dev_context *devc;
|
||||||
ssize_t idx;
|
ssize_t idx;
|
||||||
|
gboolean on;
|
||||||
GVariant *tuple_child;
|
GVariant *tuple_child;
|
||||||
enum sr_mq mq;
|
enum sr_mq mq;
|
||||||
enum sr_mqflag mqflags;
|
enum sr_mqflag mqflags;
|
||||||
|
@ -377,6 +379,22 @@ static int config_set(uint32_t key, GVariant *data,
|
||||||
return SR_ERR_ARG;
|
return SR_ERR_ARG;
|
||||||
devc->data_source = DATA_SOURCE_REC_FIRST + rec_no - 1;
|
devc->data_source = DATA_SOURCE_REC_FIRST + rec_no - 1;
|
||||||
break;
|
break;
|
||||||
|
case SR_CONF_DATALOG:
|
||||||
|
if (!devc)
|
||||||
|
return SR_ERR_ARG;
|
||||||
|
on = g_variant_get_boolean(data);
|
||||||
|
sr_err("DIAG: record start/stop %d, currently ENOIMPL", on);
|
||||||
|
return SR_ERR_NA;
|
||||||
|
/*
|
||||||
|
* TODO Send command 0x0a (start) or 0x0b (stop). Though
|
||||||
|
* start needs a name (ymd timestamp?) and interval and
|
||||||
|
* duration (arbitrary choice? 1s for 1d?). Or shall this
|
||||||
|
* SET request control "save" items instead? Take one
|
||||||
|
* sample each for every 'datalog=on' request? Combine
|
||||||
|
* limit_samples and limit_msec with datalog to configure
|
||||||
|
* a recording's parameters?
|
||||||
|
*/
|
||||||
|
break;
|
||||||
case SR_CONF_MEASURED_QUANTITY:
|
case SR_CONF_MEASURED_QUANTITY:
|
||||||
if (!devc)
|
if (!devc)
|
||||||
return SR_ERR_ARG;
|
return SR_ERR_ARG;
|
||||||
|
|
Loading…