hp-3457a: Do not retrigger new measurement after the last sample
Due to a PEBKAC error, after the last sample was sent, a new measurement was triggered, but its value was never sent down the session bus. This is easily fixed by incrementing devc->num_samples right after a measurement is sent instead of when a measurement is retriggered.
This commit is contained in:
parent
cee6d3fa0c
commit
e2626373b7
|
@ -315,8 +315,10 @@ SR_PRIV int hp_3457a_receive_data(int fd, int revents, void *cb_data)
|
|||
return FALSE;
|
||||
}
|
||||
|
||||
if (devc->acq_state == ACQ_GOT_MEASUREMENT)
|
||||
if (devc->acq_state == ACQ_GOT_MEASUREMENT) {
|
||||
acq_send_measurement(sdi);
|
||||
devc->num_samples++;
|
||||
}
|
||||
|
||||
if (devc->limit_samples && (devc->num_samples >= devc->limit_samples)) {
|
||||
sdi->driver->dev_acquisition_stop(sdi, cb_data);
|
||||
|
@ -326,7 +328,6 @@ SR_PRIV int hp_3457a_receive_data(int fd, int revents, void *cb_data)
|
|||
/* Got more to go. */
|
||||
if (devc->acq_state == ACQ_GOT_MEASUREMENT) {
|
||||
/* Retrigger */
|
||||
devc->num_samples++;
|
||||
retrigger_measurement(scpi, devc);
|
||||
}
|
||||
|
||||
|
|