gmc-mh-1x-2x: Support for interface SI232-II with driver gmc-mh-2x-bd232.
This commit is contained in:
parent
c90beca780
commit
fadd07072b
|
@ -10,7 +10,7 @@ Firmware
|
|||
--------
|
||||
|
||||
Some devices supported by libsigrok need a firmware to be uploaded every time
|
||||
the device is connected to the PC (usually via USB), before it can be used.
|
||||
the device is connected to the PC (usually via USB), before it can be used.
|
||||
|
||||
The default location where libsigrok expects the firmware files is:
|
||||
|
||||
|
@ -288,10 +288,16 @@ a short list for convenience:
|
|||
interface panel on top.
|
||||
- Digitek DT4000ZC: Briefly press the "RS232" button.
|
||||
- Gossen Metrawatt Metrahit 1x/2x devices, driver gmc-mh-1x-2x-rs232:
|
||||
Power on the device with the "DATA" button pressed. Additionally Metrahit
|
||||
2x devices must be configured for the respective interface type.
|
||||
- Power on the device with the "DATA" button pressed.
|
||||
- Metrahit 2x devices must be configured for the respective interface type.
|
||||
- Gossen Metrawatt Metrahit 2x devices, driver gmc-mh-2x-bd232:
|
||||
The device must be configured for the respective interface type.
|
||||
- 'BD232' interface:
|
||||
The multimeter must be configured for the respective interface type.
|
||||
- 'SI232-II' interface ("PC Mode"):
|
||||
The multimeter must be configured for interface type 'BD232' (all),
|
||||
'SI232 online' (28-29S) or 'SI232 store' (22-26x). The interface must
|
||||
be configured to the same baud rate as the host (default 9600).
|
||||
Multimeter and interface must be configured to the same address.
|
||||
- Norma DM950: If the interface doesn't work (e.g. USB-RS232 converter), power
|
||||
on the device with "FUNC" pressed (to power the interface from the DMM).
|
||||
- PCE PCE-DM32: Briefly press the "RS232" button.
|
||||
|
|
|
@ -436,13 +436,13 @@ static int config_get(int key, GVariant **data, const struct sr_dev_inst *sdi,
|
|||
const struct sr_probe_group *probe_group)
|
||||
{
|
||||
int ret;
|
||||
struct dev_context *devc;
|
||||
|
||||
(void)sdi;
|
||||
(void)data;
|
||||
(void)probe_group;
|
||||
|
||||
ret = SR_OK;
|
||||
struct dev_context *devc;
|
||||
|
||||
(void)probe_group;
|
||||
|
||||
|
@ -621,7 +621,7 @@ SR_PRIV struct sr_dev_driver gmc_mh_1x_2x_rs232_driver_info = {
|
|||
|
||||
SR_PRIV struct sr_dev_driver gmc_mh_2x_bd232_driver_info = {
|
||||
.name = "gmc-mh-2x-bd232",
|
||||
.longname = "Gossen Metrawatt Metrahit 2x, 'BD232' interface",
|
||||
.longname = "Gossen Metrawatt Metrahit 2x, 'BD232'/'SI232-II' interface",
|
||||
.api_version = 1,
|
||||
.init = init_2x_bd232,
|
||||
.cleanup = cleanup_2x_bd232,
|
||||
|
|
|
@ -1320,11 +1320,15 @@ int req_stat14(const struct sr_dev_inst *sdi, gboolean power_on)
|
|||
|
||||
if (power_on) {
|
||||
sr_info("Write some data and wait 3s to turn on powered off device...");
|
||||
if ((serial_write(serial, msg, sizeof(msg)) == -1) ||
|
||||
(serial_write(serial, msg, sizeof(msg)) == -1) ||
|
||||
(serial_write(serial, msg, sizeof(msg)) == -1))
|
||||
if (serial_write(serial, msg, sizeof(msg)) < 0)
|
||||
return SR_ERR;
|
||||
g_usleep(3*1000*1000);
|
||||
g_usleep(1*1000*1000);
|
||||
if (serial_write(serial, msg, sizeof(msg)) < 0)
|
||||
return SR_ERR;
|
||||
g_usleep(1*1000*1000);
|
||||
if (serial_write(serial, msg, sizeof(msg)) < 0)
|
||||
return SR_ERR;
|
||||
g_usleep(1*1000*1000);
|
||||
serial_flush(serial);
|
||||
}
|
||||
|
||||
|
|
Loading…