add support for sound pressure level measurements
This commit is contained in:
parent
258eeb77b8
commit
fc19c288b5
31
libsigrok.h
31
libsigrok.h
|
@ -173,6 +173,9 @@ enum {
|
|||
SR_MQ_POWER,
|
||||
/** Gain (a transistor's gain, or hFE, for example). */
|
||||
SR_MQ_GAIN,
|
||||
/** Logarithmic representation of sound pressure relative to a
|
||||
* reference value. */
|
||||
SR_MQ_SOUND_PRESSURE_LEVEL,
|
||||
};
|
||||
|
||||
/** Values for sr_datafeed_analog.unit. */
|
||||
|
@ -203,6 +206,8 @@ enum {
|
|||
* a unitless quantity, for example.
|
||||
*/
|
||||
SR_UNIT_UNITLESS,
|
||||
/** Sound pressure level relative so 20 micropascals. */
|
||||
SR_UNIT_DECIBEL_SPL,
|
||||
};
|
||||
|
||||
/** Values for sr_datafeed_analog.flags. */
|
||||
|
@ -225,6 +230,30 @@ enum {
|
|||
SR_MQFLAG_AUTORANGE = 0x80,
|
||||
/** Device is in relative mode. */
|
||||
SR_MQFLAG_RELATIVE = 0x100,
|
||||
/** Sound pressure level is A-weighted in the frequency domain,
|
||||
* according to IRC 61672:2003. */
|
||||
SR_MQFLAG_SPL_FREQ_WEIGHT_A = 0x200,
|
||||
/** Sound pressure level is C-weighted in the frequency domain,
|
||||
* according to IRC 61672:2003. */
|
||||
SR_MQFLAG_SPL_FREQ_WEIGHT_C = 0x400,
|
||||
/** Sound pressure level is Z-weighted (i.e. not at all) in the
|
||||
* frequency domain, according to IRC 61672:2003. */
|
||||
SR_MQFLAG_SPL_FREQ_WEIGHT_Z = 0x800,
|
||||
/** Sound pressure level is not weighted in the frequency domain,
|
||||
* albeit without standards-defined low and high frequency limits. */
|
||||
SR_MQFLAG_SPL_FREQ_WEIGHT_FLAT = 0x1000,
|
||||
/** Sound pressure level measurement is S-weighted (1s) in the
|
||||
* time domain. */
|
||||
SR_MQFLAG_SPL_TIME_WEIGHT_S = 0x2000,
|
||||
/** Sound pressure level measurement is F-weighted (125ms) in the
|
||||
* time domain. */
|
||||
SR_MQFLAG_SPL_TIME_WEIGHT_F = 0x4000,
|
||||
/** Sound pressure level is time-averaged (LAT), also known as
|
||||
* Equivalent Continuous A-weighted Sound Level (LEQ). */
|
||||
SR_MQFLAG_SPL_LAT = 0x8000,
|
||||
/** Sound pressure level represented as a percentage of measurements
|
||||
* that were over a preset alarm level. */
|
||||
SR_MQFLAG_SPL_PCT_OVER_ALARM = 0x10000,
|
||||
};
|
||||
|
||||
struct sr_context;
|
||||
|
@ -400,6 +429,8 @@ enum {
|
|||
/** The device is a demo device. */
|
||||
SR_HWCAP_DEMO_DEV,
|
||||
|
||||
/** The device can act as a sound level meter. */
|
||||
SR_HWCAP_SOUNDLEVELMETER,
|
||||
|
||||
/*--- Device configuration ------------------------------------------*/
|
||||
|
||||
|
|
Loading…
Reference in New Issue