This requires sr_hw_cleanup_all() and sanity_check_all_drivers()
to also take a context.
The (runtime) generation of the driver list now happens in sr_init()
and sr_driver_list() always returns that pre-generated list. This fixes
a segfault when (correctly) invoking multiple sr_init() and sr_exit()
calls with different contexts (caught by the unit tests).
This fixes bug #565.
Add new configuration option allowing to modify the probe factor
for oscilloscopes and power-monitors.
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
Add new config options to libsigrok - 'averaging', which allows to
enable averaging of samples and 'avg_samples' for setting the number
of samples to be averaged over in each cycle.
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
Use g_malloc0() for small allocations and assume they always
succeed. Simplify error handling in a few places accordingly.
Don't always sanity-check parameters for non-public (SR_PRIV)
functions, we require the developers to invoke them correctly.
This allows further error handling simplifications.
The automatic selections of the measured quantity and equivalent circuit
model are more part of the configuration of the meter than attributes
of the measurement result. To reflect this, model them as config keys
instead of mqflags. This allows a driver that supports remote control to
implement 'set' method for them and has the additional benefit of saveing
two flag bits.
This is intended for setting (or getting) the amplitude of a source
which doesn't really have an MQ associated with it, such as the demo
driver's analog channels.