Most Metex DMMs use e.g. " mV" as unit field, others use "mV ",
though. Support these (and other) whitespace variants by stripping all
spaces and only comparing non-space characters.
We now use zip_int64_t and zip_get_num_entries() for example, which
requires at least libzip 0.10. This version was released in 03/2012,
which is old enough that we don't necessarily have to do a work-around
for older versions. Thus, simply bump the requirement to >= 0.10.
If buf contains exactly the string "Agilent Technologies" (for example if
there are bugs in the timeout logic or serial driver causing the reply from
the meter to be abridged) then this code will SEGV. This is because tokens[1]
is NULL but only tokens[2] and tokens[3] (both of which are undefined) are
NULL checked.
Can be trivially corrected by NULL checking tokens[1] as well.
Signed-off-by: Daniel Thompson <daniel@redfelineninja.org.uk>
g_usleep(XX) sleeps for *at least* XX microseconds but may sleep for
longers (on older kernels the sleep will typically be 10000us). Thus
byte receive loops containing an unconditional sleep will perform
very poorly (for example it causes the scan in agilent-dmm to timeout
prematurely).
Even on modern kernels serial_readline() has a 2ms sleep per byte which
means it will read at a maximum rate of half a character per millisecond
(~4800baud).
This is fixed by only sleeping when read() returns no data.
Signed-off-by: Daniel Thompson <daniel@redfelineninja.org.uk>
This extends the session file format to contain logic data files named
either "logic-1" as before, or "logic-1-1", "logic-1-2", ...
representing chronologically ordered chunks of captured data.
The chunks are transparently concatenated together by sr_session_load().
This exposes the list of devices added to the session. In the case of
loading a session from file, these struct sr_dev_inst are otherwise
not exposed to the frontend. See bug 145.
This DMM is not using the standard bits in the FS9922 protocol/structure
to indicate the "volt" and "diode mode" flags. Instead, it only sets the
user-defined bit "z1" to indicate both "diode mode" and "volt".
This fixes#142.
This is no longer used, and also it is not available on Android and thus
breaks cross-compilation for Android.
Thanks Marcus Comstedt <marcus@mc.pp.se> for reporting.
For demux mode we half the channels. Previous check method broke
the OLS randomly and but it in a bad state.
Signed-off-by: Matt Ranostay <mranostay@gmail.com>
demux mode allows DDR sampling which disables group 2 & 3
and thus samples group 0 & 1 to sample on rising and falling of
the clock.
Signed-off-by: Matt Ranostay <mranostay@gmail.com>
Allow channel groups to be swapped. This is useful
for demux at 200mhz with the unbuffered channels.
Signed-off-by: Matt Ranostay <mranostay@gmail.com>
The high bit of the sample, denoting this is a count, was not getting
properly cleared. This resulted in an inevitably negative count, and
corruption of the sample buffer before it was transferred to the
frontend.
The single sample buffer, up to 4 bytes long, was not getting initialized
on (every) acquisition start, only after the first full sample was in.
This caused the first sample to potentially hold garbage.
ols allows both external and internal test patterns at ~20khz
which are helpful for unit tests and demos.
pattern=internal -> route pattern internally to all 32 pins
(input otherwise disabled)
pattern=external -> generates pattern on unbuffered pins 16:31
(which can be looped back to the buffered pins 0:15)
Signed-off-by: Matt Ranostay <mranostay@gmail.com>
Stage count was always getting incremented one more than
actual stages, and this caused a extra stage with zero'ed data
probe lines to have the start bit field.
Signed-off-by: Matt Ranostay <mranostay@gmail.com>