commit 378abfeac6 tried to solve a bug where
the fx2lafw driver would print "Device came back" even if a timeout had occured.
It solved that issue, but inadvertently introduced a new bug:
"Device came back" would be printed even if no firmware upload was performed.
This is counterintuitive, as the device is only reset when a firmware upload is
performed.
There are three cases:
i) Firmware upload was successful
ii) Firmware upload failed
iii) Firmware upload was NOT needed
Each case warrants a separate message from the driver. Print the
following messages depending on the outcome:
i) "Device came back"
ii) "Device failed to renumerate"
iii) "Firmware upload was not needed."
Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
Use the new DRIVER_LOG_DOMAIN mechanism, where explicitly writing
the driver name in the message string is no longer required.
Thus:
- sr_err("fx2lafw: Something bad happened.");
becomes:
+ sr_err("Something bad happened.");
In either case, the log output is the same.
Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
In the case of USB drivers, a driver's dev_acquisition_stop() cannot
simply remove its fd sources from the session and close its devices:
a USB transfer might still be underway, and it needs to be finished
(and its memory freed) properly.
An sr_dev_inst->status value is added: SR_ST_STOPPING, which should
be set when the driver's dev_acquisition_stop() is called, and acts
as a marker for the USB event handler to wind up its operations.
In order for dev_acquisition_stop() to be able to set the sdi status,
however, it needs to be unconstified.
These are used to list the device instances currently known to the driver,
and clear that list.
Drivers that don't necessarily clear their list of instances on every scan,
such as genericdmm, need to provide these to the frontend to keep instance
management sane.
Since probes now live in a struct sr_dev_inst owned by the driver, it
already knows about them. Instead of a frontend telling the driver to
configure probes, all driver now do this just before starting acquisition.
It's obsolete: no frontend ever used it, and neither did libsigrok.
The sdi->status field is only used internally by some drivers, and
should probably be moved to the driver-specific context structs.
This changes the semantics of the init() call as well. That now only
initializes the driver -- an administrative affair, no hardware gets
touched during this call. It returns a standard SR_OK or SR_ERR* code.
The scan() call does a discovery run for devices it knows, and returns
the number found. It can be called at any time.
It was actually used in one way: the session file loaded abused it for
passing in the filename -- something it definitely wasn't intended for.
This now uses the proper way to pass arguments to a driver: the new
SR_HWCAP_SESSIONFILE.
The OLS driver could also use it as an indication of the serial port to
use instead of actively probing all serial ports on the system, but there
wasn't any frontend code that passed in such a parameter, making it
entirely useless. That will soon be handled differently with the new
scan() API call, regardless.
Free the USB transfers in the reverse order of which they were submitted. This
will avoid that while transfer 0 is cancelledd transfer 1 is started by the
host controller, and so on.
Reported-by: Peter Stuge <peter@stuge.se>
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
All frontends will have to include <libsigrok/libsigrok.h> from now on.
This header includes proto.h and version.h, both installed from the
distribution into $INCLUDE/libsigrok/ as well.
The only dynamically changed header is now version.h, which has both
libsigrok and libtool compile-time versions in it.
Call abort_acquisition if starting sampling fails in acquisition_start, this
will ensure that all already allocated resources are being freed again.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
This may happen if the acquisition_start is called right after calling
acquisition_stop and not all transfers have been freed or on repeated calls to
acquisition_start. If it happens we'll enter an undefined state and all kind of
strange behavior may occur, so error out in such a case.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
The recent reworks of the fx2lafw made sure that the total buffer size is large
enough hold 500ms of data. This was done to improve performance and stability.
That the timeout value for a transfer was also increased to over 500ms, a side
effect of this is that when sampling is stopped there will be a additional delay
of 500ms. This is because the driver waits for all transfers to be freed
before it sends a SR_DF_END packet. Once sampling has stopped this will only
happen once a transfer times out. This patch cancels all pending transfers when
sampling is stopped, this will cause them to be freed almost immediately and the
additional delay will disappear.
Also make sure, that if we know, that we just have received the last transfer to
not resubmit this transfer again.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Currently timeout and buffer size are hard-coded in the fx2lafw driver which is
non-optimal if we want to get good results at both high and low sample rates.
The timeout is hard-coded to 40ms, which doesn't work well when sampling at
a low sample rate. E.g. at 20kHz filling all available buffer space alone takes
6 seconds. So naturally we'll see a lot of transfers timeout in this case.
The buffer size is hard-coded to 4096 bytes, which does not work well with high
sample rates. E.g. at 24MHz these 4096 bytes are enough space for 0.17ms of
data. The total buffer size is enough for about 5ms of data. Sooner or later the
application won't be able to resubmit a transfer within this time span and the
device will abort data acquisition. Usually this happens within the first few
seconds of sampling.
This patch adds a few new helper functions which calculate the buffer size and
timeout based on the current sample rate.
The buffer size is chosen to be large enough to hold about 10ms of data and it
also must be a multiple of 512 bytes since the firmware will send us the data
in 512 byte chunks.
The timeout is set to the time it would take to fill the whole available buffer
space plus a 25% headroom to accommodate for jitter. This is more than enough,
but there is no need to make the timeout a tight deadline, since it is only
meant as a last resort in case the device stops submitting data. And in this
case data acquisition will be aborted anyway.
The patch also limits the the number of transfers so that the total buffer
space is not much more of 500ms. This will ensure that we do not have to
wait too long when aborting data acquisition.
This patch also significantly reduces the number of context switches when
sampling at a higher sample rate. On my system for example the CPU load of
sigrok-cli when sampling at 24MHz goes down from ~25% to 3-4%.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
While errors are usually already implicitly caught by looking at the packet
length field there is one error status which is worth special handling. If the
device has been removed there is not really a chance to recover from this error
so data acquisition can be stopped immediately.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
In receive_transfer for each completed transfer a new buffer is allocated and
the old one is freed. We can avoid this by simply reusing the buffer for the
next transfer. This is possible if we only resubmit the transfer after all
processing on the data buffer has been done. A new buffer is only allocated if
the size of the old one is not 4096 bytes.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
When freeing a transfer we also have to free the transfer buffer. We also have
to keep track of the number of allocated transfers and if the freed transfer was
the last one stop acquisition. This patch introduces a helper function which
takes care of all of this.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>