Starting with Linux kernel version 4.9, BeagleLogic attributes
setting does not require root permissions.
Signed-off-by: Kumar Abhishek <abhishek@theembeddedkitchen.net>
This is unlike the previous behavior to return 8 channels and then
use logic_channels to get all the 14 channels
Signed-off-by: Kumar Abhishek <abhishek@theembeddedkitchen.net>
Values like '-0.1' would be parsed as being positive, as the integral
type does not discern +0 and -0. Also allow values without leading
integral value, to match behaviour of strtod/sr_atof.
There were some issues when using libftdi 0.x recently that are fixed
when switching to libftdi 1.x (not really worth the effort to investigate).
libftdi 1.x has been around several years now and should be available
in most recent distros and OSes. For the rare cases where it is not,
it's easy enough to get it via backport packages, or build from source,
or sigrok users can just use our binary installers for most OSes.
This also "fixes"/obsoletes bug #959.
This was leading to an invalid threshold config value and indirectly
to frontend issues.
Slightly modified patch from James Churchill <pelrun@gmail.com>, thanks!
The previous implementation unconditionally submitted analog data
whenever values could get extracted out of received serial packets.
This commit checks the channels' enabled state before submission. Care
is taken to obey the user's acquisition limits, exclusively counting
submitted not received values.
Upon reception of serial data from the ES51919 LCR chipset, the data for
channels P1 and P2 was extracted from the packet, and unconditionally got
sent to the sigrok session.
Do check the channels' enabled state before submission. This fixes for
serial-lcr what recently got reported for a Brymen DMM. Tested with
$ sigrok-cli -d peaktech-2170:conn=/dev/ttyUSB0 --channels P2
and other --channels specifications.
The es51919_serial_clean() routine is called by std_dev_clear_with_callback().
Common code unconditionally frees the 'priv' part. The cleanup callback only
shall release descending resources which are local to the callee and opaque
to the caller.
This fixes a double free error. Tested with PeakTech 2170.
$ sigrok-cli -d peaktech-2170:conn=/dev/ttyUSB0 --show
When the acquisition was stopped before a configured limit was reached,
no sample data was retrieved. This is because the api.c stop routine did
unregister the receive callback.
Pass the stop request to the receive routine instead when stop is called
while the acquisition is still running. Have sample data downloaded very
much like it's done for reached limits, and existing logic will run the
stop routine again after state was advanced to "idle".
Extend the 'state' tracking while we are here, mark sample download as
well (that was omitted in the previous implementation). Though the
omission was non-fatal. Move the release of 'dram_line' to some earlier
location (as soon as the resource is not needed any longer), before some
rather complex calls to other routines will execute.
Reported-By: Michael Kaplan <M.KAPLAN@evva.com>
Move the check for the capture ratio being 0..100 into the wrappers,
drop unneeded helper functions, fix incorrect variable types, minor
other consistency fixes.