Commit Graph

1076 Commits

Author SHA1 Message Date
Alexandru Gagniuc e8e9dcdd70 serial: (Trivial) add support for 4800 baud
Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
2012-10-15 17:32:58 +02:00
Alexandru Gagniuc 5fef6b9d6c .qitignore: Ignore KDE backup files
*.kate-swp files can become annoying, so ignore them.

Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
2012-10-15 17:31:19 +02:00
Bert Vermeulen 2b98e0aaab analog: support AC+DC unit modifier 2012-10-15 11:32:36 +02:00
Bert Vermeulen 17ff11240e don't accept numbers as probe identifiers in trigger string
Only the probe name, as supplied by the device driver, is accepted.
2012-10-14 14:59:07 +02:00
Uwe Hermann 33df15f144 Quick workaround for g_match_info_unref(). 2012-10-11 23:57:26 +02:00
Uwe Hermann 4a1c927fd6 README: Add status, update URL, small fixes. 2012-10-10 23:36:32 +02:00
Bert Vermeulen a5b2293fa8 updated URLs and description 2012-10-08 18:52:36 +02:00
Bert Vermeulen c750b9b194 restore pre-split ignores 2012-10-08 15:53:00 +02:00
Uwe Hermann a2e222d24f sr: struct drv_context is global now. 2012-09-27 23:29:33 +02:00
Bert Vermeulen d38d2ef0ce fluke-dmm: support for all basic 287 functionality 2012-09-25 19:53:05 +02:00
Bert Vermeulen 96b3b3d568 sr: add support for conductance measurements in Siemens 2012-09-25 19:53:05 +02:00
Bert Vermeulen aa839a5c4f sr: add support for pulse width measurements 2012-09-25 19:53:05 +02:00
Bert Vermeulen f46a36ad80 fluke-dmm: definitely use CR as line terminator 2012-09-25 19:53:05 +02:00
Bert Vermeulen acd29accb3 fluke-dmm: add Fluke 287 to supported list 2012-09-25 19:53:05 +02:00
Bert Vermeulen fb9d3bf9cc sr: always turn off ICRNL on serial ports
It does rather screw with protocols that use CR.
2012-09-25 19:53:05 +02:00
Bert Vermeulen d3f8f1415c fluke-dmm: flesh out the driver API 2012-09-25 19:53:05 +02:00
Bert Vermeulen 4129832014 fluke-dmm: auto-discover serial bitrate if not provided 2012-09-25 19:53:05 +02:00
Bert Vermeulen bc41e012e6 fluke-dmm: don't log anything if no conn params given 2012-09-25 19:53:05 +02:00
Bert Vermeulen fb480d578e fluke-dmm: fix discovery 2012-09-25 19:53:05 +02:00
Bert Vermeulen 5c51e09868 sr: turn off canonical mode and echo ion serial ports by default 2012-09-25 19:53:05 +02:00
Bert Vermeulen e7edd64f45 fluke-dmm: build fixes 2012-09-25 19:53:05 +02:00
Bert Vermeulen 4f958423d1 fluke-dmm: basic scan functionality 2012-09-25 19:53:05 +02:00
Bert Vermeulen 883a2e9e71 fluke-dmm: initial driver skeleton 2012-09-25 19:53:05 +02:00
Bert Vermeulen c2016fa0eb agilent-dmm: don't log anything if no conn params given 2012-09-17 00:00:27 +02:00
Bert Vermeulen e9022f596d sr: make struct drv_context global 2012-09-11 21:27:26 +02:00
Bert Vermeulen f5cfe894ec fx2lafw: use default libusb context 2012-09-11 21:20:50 +02:00
Bert Vermeulen 19b0cce312 hantek-dso: use default libusb context 2012-09-11 21:16:16 +02:00
Bert Vermeulen 7c1cb432b8 sr: enable genericdmm and agilent-dmm drivers by default 2012-09-10 22:14:37 +02:00
Bert Vermeulen b186aa78b8 agilent-dmm: fix model identifiers 2012-09-10 21:27:50 +02:00
Bert Vermeulen 8c0152f29b agilent-dmm: tentative support for all U123x and U125x models
Only tested on U1233A, but it just might work.

The U125x protocol decoding only supports voltage, current, resistance,
capacitance and diode measurements for now.
2012-09-10 01:00:48 +02:00
Bert Vermeulen a4394fb3d9 agilent-dmm: code cleanup
This should make it easier to support other Agilent U12xx models
2012-09-10 00:13:26 +02:00
Bert Vermeulen e066c32a25 agilent-dmm: fix AC/DC mode detection 2012-09-09 22:49:07 +02:00
Bert Vermeulen f2e86bbfa6 agilent-dmm: make parser deal with input better 2012-09-09 22:48:22 +02:00
Bert Vermeulen 81599cc55b agilent-dmm: remove IDN check at 1Hz, we just don't need it.
Some debug message cleanup.
2012-09-08 14:53:49 +02:00
Bert Vermeulen 161a8a2726 sr: add new analog output module
This outputs text representation of SR_DF_ANALOG packets. Unlike the
float module however, it also outputs the standard abbreviations of
SI units corresponding to the packet's MQ and unit.

It also makes an effort to multiply or divide the floating point value
as needed to the nearest multiple or fraction, and inserts the
appropriate SI prefix to match.
2012-09-08 13:24:48 +02:00
Bert Vermeulen e6b021f377 agilent-dmm: support for submodes 2012-09-08 03:06:45 +02:00
Bert Vermeulen f45b759014 sr: add recv/cleanup calls to output module API
The new output module callbacks will be init, recv and cleanup. The
existing data  and event callbacks still work, but will be phased out
as existing modules get converted.

The recv() callback gets a copy of every packet on the session bus,
and thus has visibility of all metadata, allowing it to properly
output any acquired data.
2012-09-08 02:31:08 +02:00
Bert Vermeulen 69a7402490 genericdmm/victor-70c: fix resistance and frequency measurements 2012-09-08 02:28:41 +02:00
Joel Holdsworth 4cc9aea15b sr: Refactored sr_samplerate_string into a more general function: sr_si_string_u64 2012-09-03 13:53:09 +02:00
Lars-Peter Clausen b863fb1b9d sr: session_driver: Remove source on completion
Remove the session source once we are done loading the file, otherwise we'll
spin forever in sr_session_run.

Reported-by: Joel Holdsworth <joel@airwebreathe.org.uk>
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
2012-09-02 19:17:57 +02:00
Bert Vermeulen 40578aa487 sr: output up to 12 significant digits for floats 2012-09-02 15:42:56 +02:00
Bert Vermeulen c0d93341cb generic-dmm: cosmetics 2012-09-02 15:42:56 +02:00
Bert Vermeulen f6b8ffa6c0 genericdmm/victor-70c: warn if detaching kernel driver fails 2012-09-02 15:42:56 +02:00
Bert Vermeulen e93cdf428c sr: mostly finished Agilent DMM driver 2012-09-02 15:42:56 +02:00
Bert Vermeulen 792fc68658 serial: add serial_set_paramstr() 2012-09-02 15:42:56 +02:00
Bert Vermeulen f38b9763fa serial: fix flow control setting 2012-09-02 15:42:56 +02:00
Bert Vermeulen 6a6e23abf5 serial: set speed in both directions 2012-09-02 15:42:56 +02:00
Bert Vermeulen 6ac0db19f3 sr: add new agilent-dmm driver (Agilent U12xxA multimeters) 2012-09-02 15:42:56 +02:00
Bert Vermeulen b84c13d700 genericdmm: Victor 70C multimeter support 2012-08-18 16:23:08 +02:00
Bert Vermeulen 3c6ce226de genericdmm: finish basic USB support 2012-08-18 16:23:08 +02:00