The config.h file must always be included as first file.
src/output/csv.c: In function 'gen_header':
src/output/csv.c:64:20: warning: format '%u' expects argument of type 'unsigned int', but argument 3 has type 'uint64_t {aka long long unsigned int}' [-Wformat=]
#define LOG_PREFIX "output/csv"
^
./src/libsigrok-internal.h:753:42: note: in expansion of macro 'LOG_PREFIX'
#define sr_info(...) sr_log(SR_LOG_INFO, LOG_PREFIX ": " __VA_ARGS__)
^
src/output/csv.c:244:3: note: in expansion of macro 'sr_info'
sr_info("Set sample period to %" PRIu64 " %s",
^
src/output/csv.c: In function 'dump_saved_values':
src/output/csv.c:462:34: warning: format '%u' expects argument of type 'unsigned int', but argument 3 has type 'uint64_t {aka long long unsigned int}' [-Wformat=]
g_string_append_printf(*out, "%" PRIu64 "%s",
^
In file included from src/hardware/ftdi-la/protocol.c:21:0:
src/hardware/ftdi-la/protocol.c: In function 'send_samples':
src/hardware/ftdi-la/protocol.h:28:20: warning: format '%u' expects argument of type 'unsigned int', but argument 3 has type 'uint64_t {aka long long unsigned int}' [-Wformat=]
#define LOG_PREFIX "ftdi-la"
^
./src/libsigrok-internal.h:751:42: note: in expansion of macro 'LOG_PREFIX'
#define sr_spew(...) sr_log(SR_LOG_SPEW, LOG_PREFIX ": " __VA_ARGS__)
^
src/hardware/ftdi-la/protocol.c:29:2: note: in expansion of macro 'sr_spew'
sr_spew("Sending %" PRIu64 " samples.", samples_to_send);
^
Optionally create multiple analog channels in serial-dmm's scan()
routine. Allow the meters' parse routines to fill in more than one
analog value from the inspection of a single packet.
Use "large" (4 times 14 bytes) packets for the Metex M-3860M and the
PeakTech 4390A meters, and have those large packets parsed by wrapping
the routines for regular 14-byte Metex packets, and sending four values
to the session bus after reception of one large packet.
Thanks to Frank Stettner <frank-stettner@gmx.net> for testing and
fixing the initial implementation of this extension.
Move the initial assignment to the 'offset' variable to the very spot
where it gets evaluated and subsequently manipulated.
Replace a DIY copy loop with the corresponding memmove(3) call.
Also use "r" and "f" as trigger slope values for now, since that's
what most other drivers do currently.
This also fixes two scan-build issues:
api.c:559:3: warning: Value stored to 'tmp_str' is never read
tmp_str = g_variant_get_string(data, NULL);
^ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
api.c:561:9: warning: Use of memory after it is freed
ret = siglent_sds_config_set(sdi, "%s:TRSL %s",
^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
The strcasestr() function is non-portable (e.g. not available on
MinGW, possibly elsewhere). Replace it with g_strstr_len() for the time
being. While the latter is not case-insensitive it appears that
that property doesn't matter here ("." should not be relevant anyway,
and e.g. an SDS1202X-E does indeed report "Mpts" as such).
Should it become necessary to have this code be case-insensitive,
we'll have to find a more portable solution than strcasestr().
This causes some compile errors on platforms where RPC is not available, e.g.
siglent-sds/api.c:25:21: fatal error: rpc/rpc.h: No such file or directory
Surrounding the #include (and later code) with "#if HAVE_RPC" should avoid
these compile errors, but since it's not used at all for now, drop it.
Make the USB reset for USB TMC devices conditional. Check a whitelist,
which in this implementation exclusively contains the Siglent VID.
The whitelist's comment may need adjustment. The VID probably not only
applies to SDS devices, but could be used for SDG and others as well.
And lsusb output suggests the VID is used by Atten, too.
Add the Siglent's VID to a list of blacklisted USB TMC devices.
Unconditionally reset USB devices in the open routine.
This was taken from marchel's development for Siglent SDS. Though the
reset should probably be conditional, and only get applied to devices
which are known to need it.
The comment may need adjustment, maybe individual PID entries are
required. The VID probably not only applies to SDS devices, but could
be used for SDG and other gear as well. And lsusb output suggests the
VID is used by Atten, too.
Implement a first version of the driver for the Siglent SDS1000 and
SDS2000 oscilloscopes.
[ gsi: This commit corresponds to git 0228126017e6 of marchelh's tree,
I adjusted the source to closer match the project's coding style. The
conversion was verified by this command:
$ git diff --word-diff=color -w -b <branch>:<dir> <branch>:<dir>
Changes include: Whitespace adjustment, dead code removal, separation
of variable declaration and assignment, alpha-sorted includes. Line
length was not addressed and not every location got adjusted, to keep
the diff minimal and to reduce effort during review of this version. ]
The conn= specification is not strictly related to RS232 communication.
Provide examples for other USB specs (as they are used for some DMM and
LCR drivers), as well as TCP and VXI (which are often found with MSO
drivers).
Check for successful allocation before accessing struct members. Return
with an error from device initialization when allocation fails.
This was reported by clang's scan-build.
Make sure to release the allocated "pod enabled" memory, too, when SCPI
communication during channel setup fails. Defer the return with an error
(instead of duplicating the free() invocation).
This was reported by clang's scan-build.
The compiler marks a potential use after free, which the current
implementation won't trigger. The error only occurs when a sigrok
channel is neither logic nor analog.
Address the issue nevertheless, to silence the compiler warning, and to
protect against possible programming errors when a future implementation
should support more channel types.
This was reported by clang's scan-build.
Fixup unbalanced braces for more complex if statements, to better
reflect the project's official coding style.
Adjust data types in the float_to_le() routine. A float value gets
copied to a buffer of bytes (uint8_t). Don't use 'char' on the other
side of assignments, to not assume a specific width for char, and to
avoid potential signedness issues. Copy from bytes to bytes instead.
The WAV output module supports an optional 'scale' factor, in its
absence the samples will pass unmodified. The builtin help text is
unexpected, and reads:
$ sigrok-cli -O wav --show
...
Options:
scale: Scale values by factor (default 0.0)
Setup a default scale factor of 1.0, which results in identical
behaviour and better reflects what is happening.
The previous implementation only emitted data for the first enabled
channels, and "saw no changes" after emission of the initial value for
channels on positions that followed a disabled channel.
Assume that the received data from the session bus communicates the bits
of enabled channels in a packed representation. Skip the mapping of
output bit indices to sigrok channel numbers.
This fixes the remaining part of bug #519.
Tested by inspecting in gtkwave the result of command:
$ sigrok-cli -d demo -C D1,D3,D6 -c samplerate=2M --samples 2500 -O vcd -o trace.vcd
When we find that all input sources (device drivers, and input modules)
provide a dense bit field, all of the mapping logic can get removed
here. This commit just quickly disables the logic.
Identifiers for channels in the VCD header section could be "sparse"
when sigrok channels were disabled. Make sure to not assign names to
disabled channels. This will e.g. assign !, ", and # to channels D1, D3,
and D6, when D0, D2, D4-D5, and D7 are disabled.
This addresses part of bug #519.