Gerhard Sittig a10284cd18 serial-hid: introduce support for Brymen BU-86X IR adapters
The Brymen BU-86X infrared adapters are sold with BM869s meters. Raw
streams of data bytes get communicated by means of HID reports with
report number 0 and up to 8 data bytes each. Communication parameters
are fixed and need no configuration.