Gerhard Sittig 503519b70a lsr/es51919: support channel selection (enable/disable P1/P2)
Upon reception of serial data from the ES51919 LCR chipset, the data for
channels P1 and P2 was extracted from the packet, and unconditionally got
sent to the sigrok session.

Do check the channels' enabled state before submission. This fixes for
serial-lcr what recently got reported for a Brymen DMM. Tested with

  $ sigrok-cli -d peaktech-2170:conn=/dev/ttyUSB0 --channels P2

and other --channels specifications.
2017-08-19 19:21:53 +02:00
Gerhard Sittig 12788e7e40 lcr/es51919: clean but don't free dev context in cleanup callback
The es51919_serial_clean() routine is called by std_dev_clear_with_callback().
Common code unconditionally frees the 'priv' part. The cleanup callback only
shall release descending resources which are local to the callee and opaque
to the caller.

This fixes a double free error. Tested with PeakTech 2170.

  $ sigrok-cli -d peaktech-2170:conn=/dev/ttyUSB0 --show
2017-08-19 19:21:51 +02:00
Uwe Hermann 53012da658 drivers: Use ARRAY_AND_SIZE where possible. 2017-07-21 17:06:40 +02:00
Uwe Hermann ca314e060f drivers: Drop unneeded or duplicate comments.
Drop various comments which are not really needed, too verbose, document
obvious things, are duplicated across all drivers, or simply incorrect.
2017-07-21 15:23:56 +02:00
Uwe Hermann 05199c0ac9 drivers: Provide proper drvopts.
The device class config keys should be in drvopts (not devopts).
2017-07-19 15:39:23 +02:00
Uwe Hermann e66d1892d0 drivers: Add and use STD_CONFIG_LIST().
This ensures consistent handling of the SR_CONF_SCAN_OPTIONS and
SR_CONF_DEVICE_OPTIONS (with sdi NULL or non-NULL) config keys
and also reduces copy-pasted boilerplate in the drivers a bit.

This function does not handle channel-group specific items, that's
very driver-specific and thus left to the individual drivers.

Also move some generic checks and error messages from the drivers into
the sr_config_list() wrapper.
2017-07-19 15:11:01 +02:00
Uwe Hermann f670835f1f Add sr_dev_acquisition_start(), factor out SR_ERR_DEV_CLOSED check.
This ensures consistent checks and log messages across all drivers
and reduces the per-driver boilerplate.
2017-07-07 21:51:16 +02:00
Uwe Hermann d2f7c417fd Add sr_dev_acquisition_stop(), factor out SR_ERR_DEV_CLOSED check.
This ensures consistent checks and log messages across all drivers
and reduces the per-driver boilerplate.
2017-07-07 21:51:10 +02:00
Uwe Hermann 04891a997c sr_serial_dev_inst_free(): Allow NULL as argument. 2017-03-10 11:41:34 +01:00
Uwe Hermann 4bf9398802 sr_dev_inst_free(): Allow NULL as argument. 2017-03-10 11:38:12 +01:00
Gerhard Sittig 6b7e644e5c es51919 lcr: unbreak channel setup after successful detection
Commit 6bcb3ee876 introduced initial support for the Cyrustek ES51919
chipset. Its setup_channels() routine used to init a variable to assume
failure, then a loop added channels and changed the value to success.

Commit 5e23fcab88 changed channel setup to never fail, but kept the
initialization with an error code. Which prevented the operation of
successfully detected LCR meters.

Remove the no longer needed variable, instead always return success from
an operation which cannot fail.

Fixes: 5e23fcab88 "Simplify channel creation."
Signed-off-by: Gerhard Sittig <gerhard.sittig@gmx.net>
2016-11-02 23:27:56 +01:00
Uwe Hermann 693c52482a es51919: Fix a compiler warning.
src/lcr/es51919.c:538:73: warning: comparison of unsigned enum expression \
		< 0 is always false [-Wtautological-compare]
    if ((analog->meaning->mq = parse_mq(pkt, is_secondary, pkt[2] & 0x80)) < 0)
2016-08-29 21:51:28 +02:00
Uwe Hermann d9251a2c9f Remove some unneeded double-spaces.
(also perform some other minor whitespace fixes while at it)
2016-08-29 21:51:27 +02:00
Uwe Hermann 869c837511 Document if or why sometimes digits/spec_digits is 0. 2016-08-29 00:25:19 +02:00
Aurelien Jacobs 24b6882ffa deree-de5000: properly set encoding digits 2016-08-23 12:58:05 +02:00
Uwe Hermann 7ffcf58736 lcr: Convert to SR_DF_ANALOG. 2016-06-16 15:05:00 +02:00
Lars-Peter Clausen 4b1a9d5d86 Remove unnecessary std_serial_dev_acquisition_stop() wrappers
Now that std_serial_dev_acquisition_stop() has the same signature as
the sr_dev_driver dev_acquisition_stop() callback it is possible to remove
the wrapper functions and use std_serial_dev_acquisition_stop() directly
has the callback function.

Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
2016-05-31 15:54:53 +02:00
Lars-Peter Clausen 1b38775baa std_serial_dev_acquisition_stop(): Remove dev_close_fn parameter
All callers of std_serial_dev_acquisition_stop() currently pass the same
callback for the dev_close_fn parameter as the dev_close callback of their
sr_dev_driver struct. Remove the dev_close_fn parameter and invoke the
drivers dev_close() callback directly. This simplifies the API and ensures
consistent behaviour between different drivers.

Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
2016-05-31 15:54:52 +02:00
Lars-Peter Clausen 15f96409dc std_serial_dev_acquisition_stop(): Remove serial parameter
All callers of std_serial_dev_acquisition_stop() currently pass sdi->conn
for the serial parameter. And the other std_serial helper functions already
require that the conn field of the sr_driver_inst passed to the functions
points to the sr_serial_dev_inst associated with the device.

Modify std_serial_dev_acquisition_stop() to follow the same pattern and
remove the serial parameter. This simplifies the API and ensures consistent
behaviour between different drivers.

Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
2016-05-31 15:54:52 +02:00
Lars-Peter Clausen bee2b0168c Use driver name as the log prefix in standard functions
Some of the standard helper functions take a log prefix parameter that is
used when printing messages. This log prefix is almost always identical to
the name field in the driver's sr_dev_driver struct. The only exception are
drivers which register multiple sr_dev_driver structs.

Instead of passing the log prefix as a parameter simply use the driver's
name. This simplifies the API, gives consistent behaviour between different
drivers and also makes it easier to identify where the message originates
when a driver registers sr_dev_driver structs.

Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
2016-05-31 15:54:52 +02:00
Uwe Hermann 4d399734b4 config_list: Don't check for sdi->priv != NULL.
If sdi is != NULL, the backend ensures that sdi->priv is also != NULL.
Almost all drivers were relying on this already.
2016-05-17 01:12:56 +02:00
Uwe Hermann 709468baf7 config_get(): Don't check for sdi->priv != NULL.
If sdi is != NULL, the backend ensures that sdi->priv is also != NULL.
Almost all drivers were relying on this already.
2016-05-17 01:12:56 +02:00
Uwe Hermann 6525d819ee std_serial_dev_acquisition_stop(): Drop unneeded parameter. 2016-04-29 19:20:53 +02:00
Uwe Hermann 695dc859c1 dev_acquisition_{start,stop}(): Drop duplicate 'cb_data' parameter.
These are always 'sdi', which is passed in already.
2016-04-29 19:20:53 +02:00
Uwe Hermann 1c47e0da8f Drop unneeded std_session_send_df_header() comments. 2016-04-29 18:08:15 +02:00
Uwe Hermann 5faebab290 SR_DF_ANALOG_OLD and sr_datafeed_analog_old renames.
Rename SR_DF_ANALOG to SR_DF_ANALOG_OLD, and 'struct sr_datafeed_analog'
to 'struct sr_datafeed_analog_old'.
2015-10-20 23:32:45 +02:00
Daniel Elstner 6ec6c43b47 Build: Include <config.h> first in all source files
Since Autoconf places some important feature flags only into the
configuration header, it is necessary to include it globally to
guarantee a consistent build.
2015-09-13 18:54:46 +02:00
Bert Vermeulen 83478149b1 deree-de5000: Drop SR_CONF_MEASURED_QUANTITY functionality.
This was superfluous -- there is no need to be able to query the
last MQ(s) sent by the device, since they're already being sent
along with the measurements in analog packets.

Since there is also no way to change the MQ (that is done with the
buttons on the device), there is no need to even list the possible
MQs.
2015-08-30 20:40:56 +02:00
Daniel Glöckner 80e20c10e3 es51919: fix memory leak
This fixes bug #629.
2015-08-30 18:48:50 +02:00
Daniel Elstner c1aae90038 Build: Set local include directories in Makefile.am
Move the include flags for files in the source tree from
configure.ac to Makefile.am where they belong.  Also use
AM_CPPFLAGS instead of CFLAGS/CXXFLAGS to make sure the
files in the build/source tree are always picked up first.

Also, remove the include/libsigrok sub-directory from the
search path, thereby making the <libsigrok/> prefix mandatory
when building libsigrok itself.  This matches the convention
already imposed on users of the library.
2015-08-16 18:28:12 +02:00
Alexandru Gagniuc b94dd07b08 global: Treat SR_CONF_OUTPUT_FREQUENCY as float instead of uint64_t
This makes 'output_frequency' symmetrical with 'output_current' and
'output_voltage'. On a more fundamental level, there's no reason why
frequency should be treated as a discrete quantity, other than
"es51919 used it this way".
2015-05-06 10:25:16 -07:00
Uwe Hermann 1beccaed46 Various minor whitespace fixes. 2015-03-21 19:28:54 +01:00
Martin Ling 5e23fcab88 Simplify channel creation.
We always follow sr_channel_new() with a call to add the channel to the sdi.
Tidy up a bit by adding this functionality to sr_channel_new() instead.
2015-03-19 21:37:33 +00:00
Janne Huttunen 787ec9dbd9 Limit frames instead of samples.
Since every individual measurement is represented by a single frame
and a "sample" isn't all that meaningful concept in this context,
it makes more sense to define possible limit in number of frames.
Make the es51919 driver to support setting a frame limit instead of
a sample limit.
2015-01-06 20:10:17 +01:00
Janne Huttunen a6413fa58e Use frames to group a single measurement result together.
In most, but not all, modes the ES51919 reports two separate
analog values for each measurement sample. These values are
mapped to two separate channels and sent in two separate
packets.

A client program needs a way to determine which results are
parts of the same measurement and also know when a complete
measurement is received so it can process the sample. Use
the frame begin and end packets to separate groups that each
represent a single complete measurement.
2015-01-06 20:10:17 +01:00
Janne Huttunen bb983c666a Fix the channel indexes of the es51919 driver.
Set the channel indexes to unique values instead of setting
them all zero.
2015-01-06 20:10:17 +01:00
Uwe Hermann 91219afc75 Use g_malloc0() consistently, simplify error handling.
Use g_malloc0() for small allocations and assume they always
succeed. Simplify error handling in a few places accordingly.

Don't always sanity-check parameters for non-public (SR_PRIV)
functions, we require the developers to invoke them correctly.
This allows further error handling simplifications.
2014-11-22 17:02:57 +01:00
Uwe Hermann c368e6f3d2 Don't check sr_channel_new() return value (always succeeds).
We now use g_malloc0() for the allocation and assume the allocation
will always succeed, thus sr_channel_new() will always return a
valid new channel.
2014-11-21 12:10:05 +01:00
Uwe Hermann f57d8ffe66 Consistently use g_malloc0() for allocating devc.
We assume the allocation will always succeed, hence no need for
checking the returned value.
2014-11-21 12:09:01 +01:00
Uwe Hermann aac29cc192 Eliminate sr_dev_inst_new(). 2014-11-21 02:01:36 +01:00
Uwe Hermann 0af636bed9 Change sr_dev_inst_new() to take no parameters.
Change all callers to set the fields manually as needed.
2014-11-12 17:18:46 +01:00
Janne Huttunen a42a39ac37 Export LCR meter 'auto' bits as config keys instead of mqflags.
The automatic selections of the measured quantity and equivalent circuit
model are more part of the configuration of the meter than attributes
of the measurement result. To reflect this, model them as config keys
instead of mqflags. This allows a driver that supports remote control to
implement 'set' method for them and has the additional benefit of saveing
two flag bits.
2014-10-21 12:23:20 +02:00
Bert Vermeulen 99d090d8e5 Fix typos. 2014-10-18 23:21:37 +02:00
Janne Huttunen c7c8994c20 Rename "SERIAL" -> "SERIES".
Use the more correct term "SERIES" for the corresponding equivalent
circuit model.
2014-10-17 12:13:51 +02:00
Uwe Hermann b9a348f56c Rename SR_CONF_LCR_METER to SR_CONF_LCRMETER.
(to be consistent with some other key names)
2014-10-13 11:39:15 +02:00
Janne Huttunen 6bcb3ee876 Add protocol decoder for Cyrustek ES51919 LCR meter chip.
Add a protocol decoder for the Cyrustek ES51919 LCR meter chip.
This chipset (together with ES51920 front-end) is supposedly used
by multiple different portable LCR meters including at least
DER EE DE-5000, Yihua V&A VA520, Mastech MS5308, Uni-T UT612,
CEM DT-9935 and various OEM rebadges of them.

The communication protocol seems to be implemented on the Cyrustek
chip itself so all the different models are expected to use the
same protocol if they implement a host connection. Unfortunately
the protocol is not available in the public documentation of the
chipset, so this implementation is based on reverse engineering it
from traffic captures.

The actual connection between the meter and the host computer may be
different from meter to meter even when based on the same chip. This
module implements a decoder for the protocol and some common helper
functions for interfacing with the meter via an RS-232 serial port.
2014-10-13 00:56:11 +02:00