If there is no trigger, don't try to capture anything before it. There
won't be any because we trigger immediately.
Signed-off-by: Russ Dill <Russ.Dill@gmail.com>
This reworks the triggerbar/trigger address logic to match the values sent
by the windows app for all models (The zerominus tool was used to reprogram
the USB device ID on a single device). Additionally, the DONT_CARE_TRIGGERBAR
register is always set by the windows app and does not seem to indicate that
these registers are "don't care"'s.
The currently supported model LAP-C(16032) doesn't support the
samplerates 150MHz and 200MHz which some of the other models have.
Thus, do not report these samplerates to the frontends. E.g. sigrok-cli
should not show them via --show and GUIs should not list them in their
"Samplerates" drop-down.