Commit Graph

2252 Commits

Author SHA1 Message Date
Uwe Hermann 360079e78e configure.ac: Bump libtool/library version from 1:1:0 to 1:2:0.
The libtool current:revision:age numbers change from 1:1:0 to 1:2:0
(i.e., revision is increased) since the library source code has changed,
but no interfaces were added or changed or removed.

Details:
http://www.gnu.org/software/libtool/manual/libtool.html#Updating-version-info

This changes the library filename (e.g. on Linux) from libsigrok.so.1.0.1
to libsigrok.so.1.0.2, but the SONAME (+symlink) remains the same
(libsigrok.so.1) since this release is API- and ABI-compatible with the last.
2013-11-04 01:28:12 +01:00
Uwe Hermann 3f6549307b configure.ac: Bump package version to 0.2.2. 2013-11-04 01:24:49 +01:00
Uwe Hermann 8e2da1a650 NEWS: Update for upcoming 0.2.2 release. 2013-11-04 01:24:49 +01:00
Uwe Hermann d69d26429f output/analog: SR_UNIT_REVOLUTIONS_PER_MINUTE: Add missing break. 2013-11-04 01:14:57 +01:00
Uwe Hermann 21d464a7e5 contrib/z60_libsigrok.rules: Also mention UNI-T UT325.
The same USB/HID based IC is used in the UNI-T UT-D04 cable (for various
multimeters) and the UNI-T UT325 thermometer.
2013-11-04 01:14:57 +01:00
Uwe Hermann 8823146edf contrib/z60_libsigrok.rules: Add entry for the Saleae Logic16. 2013-11-04 01:14:57 +01:00
Uwe Hermann 5724a20af7 configure.ac: Fix list sorting (cosmetic). 2013-11-04 01:14:57 +01:00
Uwe Hermann 122d33d47d configure.ac: Move a teleinfo snippet to the correct place.
This breaks some configure use-cases otherwise.
2013-11-04 01:14:57 +01:00
Uwe Hermann 9b2f03bbd2 README.devices: uni-t-dmm devices need VID/PID now. 2013-11-04 01:14:57 +01:00
Uwe Hermann 5fa12e93e3 README.devices: Updates. 2013-11-04 01:14:57 +01:00
Uwe Hermann 53f05fa80f doxygen: @since tags document only last API change.
If a function existed before but the API changed, the @since
tag only reflects the release of the last API change.
2013-11-04 01:14:56 +01:00
Uwe Hermann ef1020f9cb HACKING: Updates, some additions. 2013-11-04 01:14:56 +01:00
Dan Horák b775d753e3 rigol-ds1xx2: detect Rigol DS1xx2 with upgraded bandwith
The bandwith in Rigol DS1xx2D/E scopes can be upgraded to 150 MHz in software.
So detect also scopes with the upgraded bandwith.

using libsigrok-0.2.1 + this change + commit da970d24ec (required for newer kernels):

[dan@eagle sigrok]$ sigrok-cli --scan -d rigol-ds1xx2 -l 5
sr: libsigrok loglevel set to 5.
sr: Sanity-checking all drivers.
sr: Sanity-checking all input modules.
sr: Sanity-checking all output modules.
srd: libsigrokdecode loglevel set to 5.
sr: hwdriver: Initializing driver 'rigol-ds1xx2'.
sr: serial: Opening serial port '/dev/usbtmc0' (flags 1).
sr: serial: Opened serial port '/dev/usbtmc0' (fd 7).
sr: serial: Wrote 5/5 bytes (fd 7).
sr: serial: Closing serial port /dev/usbtmc0 (fd 7).
sr: rigol-ds1xx2: response: /dev/usbtmc0 [Rigol Technologies,DS1152D,DS1EU150XXXXXX,00.04.01.00.02]
sr: hwdriver: Scan of 'rigol-ds1xx2' found 1 devices.
The following devices were found:
rigol-ds1xx2 - Rigol Technologies DS1152D 00.04.01.00.02 with 18 probes: CH1 CH2 D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 D13 D14 D15
2013-11-03 14:20:47 +01:00
Uwe Hermann 3a8cad9137 metex14: Handle a few missing cases for overflow. 2013-10-31 13:47:30 +01:00
Uwe Hermann 88f544f27e Add support for the Metex M-4650CR.
(the Voltcraft M-4650CR is a rebadged Metex M-4650CR)
2013-10-30 14:44:44 +01:00
Uwe Hermann 2b83d7fee1 Add support for the Voltcraft M-4650CR. 2013-10-30 14:44:44 +01:00
Marc Schink 4a35548bbe Initial Comma-separated values (CSV) input support. 2013-10-30 14:43:56 +01:00
Uwe Hermann 6bf4273ee8 Fix two FreeBSD build issues related to libusb-1.0.
FreeBSD's libusb-1.0 compatible library has a few differences compared
to the "normal" libusb-1.0 from libusb.org which we have to work around.

LIBUSB_CLASS_APPLICATION doesn't exist in FreeBSD's libusb, and
libusb_handle_events_timeout_completed() doesn't exist either.
The latter is basically libusb_handle_events_timeout() with an extra
(unused by us) parameter, so the workaround is relatively simple.

This fixes bug #185.
2013-10-28 22:59:32 +01:00
Uwe Hermann 71185b48a1 Unit tests for 'binary' input format & version APIs. 2013-10-28 22:08:34 +01:00
Uwe Hermann e790bd5cda norma-dmm: Minor cosmetics, coding-style, consistency fixes.
Also, add a missing "%" in an sr_err() and a missing parameter in
another sr_err().
2013-10-25 21:25:26 +02:00
Matthias Heidbrink f8e76e2e74 norma dmm: Implemented driver. 2013-10-25 21:25:26 +02:00
Matthias Heidbrink bfd48770fc norma dmm: Initial driver skeleton. 2013-10-25 21:25:26 +02:00
Matthias Heidbrink 1477a9a6dc std.c: Changed return value of std_dev_acquisition_stop_serial() for non-active device to SR_ERR_DEV_CLOSED for consistency with other functions. 2013-10-25 21:25:26 +02:00
Matthias Heidbrink 50a9aba21b serial: Removed flag OPOST (turn off all output processing). 2013-10-25 19:11:15 +02:00
Matthias Heidbrink a510d55571 serial: Added flags CLOCAL (ignore modem status lines) and CREAD (start receiver). 2013-10-25 19:11:15 +02:00
Matthias Heidbrink 1b943b6d8b serial: Added flag IXANY (any char will restart) to XON/XOFF handshaking. 2013-10-25 19:11:14 +02:00
Sean Young 0c30b35fce saleae-logic16: claim device before using it
The kernel warns:

[ 7461.925685] usb 2-4: usbfs: process 11303 (sigrok-cli) did not claim interface 0 before use
2013-10-24 16:01:46 +01:00
Aurelien Jacobs 5542bee61b teleinfo: actual parser implementation 2013-10-24 15:41:11 +01:00
Aurelien Jacobs 8e796cb438 teleinfo: Initial driver skeleton. 2013-10-24 15:41:11 +01:00
Aurelien Jacobs 45315d0460 add energy meter device type and related units 2013-10-24 15:41:11 +01:00
Uwe Hermann c02dc3e261 metex14: Add support for pF (picofarad).
This is used on some Metex DMMs.
2013-10-23 18:41:13 +02:00
Uwe Hermann ee6cb5a417 metex14: Use case-insensitive string compares.
This allows some other DMMs to be supported that use e.g. "kOhm" vs.
"KOhm", and so on.
2013-10-23 18:07:54 +02:00
Uwe Hermann 1a807c13fc metex14: Support DMMs with slightly different protocol.
This adds support for DMMs with 5 digits in the protocol (instead of 4)
and some more whitespace variants.
2013-10-23 18:06:15 +02:00
Uwe Hermann 71f1302b4b metex14: Support DMMs with whitespace differences.
Most Metex DMMs use e.g. "  mV" as unit field, others use "mV  ",
though. Support these (and other) whitespace variants by stripping all
spaces and only comparing non-space characters.
2013-10-23 17:31:14 +02:00
Aurelien Jacobs bfb926c1d2 es519xx: restore correct packet size 2013-10-21 00:35:23 +02:00
Matthias Heidbrink b21d7eebe2 serial: Changed order of flags PARENB and PARODD in deletion to same order as in setting (cosmetic). 2013-10-18 16:58:33 +02:00
Uwe Hermann 8819bf5a96 Bump libzip requirement to >= 0.10.
We now use zip_int64_t and zip_get_num_entries() for example, which
requires at least libzip 0.10. This version was released in 03/2012,
which is old enough that we don't necessarily have to do a work-around
for older versions. Thus, simply bump the requirement to >= 0.10.
2013-10-16 18:10:29 +02:00
Bert Vermeulen 568dcacc1a Better error reporting on session start failure 2013-10-16 10:40:53 +02:00
Aurelien Jacobs df6b0f99af ISO-TECH IDM103N: remove the useless -ser postfix 2013-10-13 14:54:54 +02:00
Aurelien Jacobs 94e9021b3e es519xx: correct initialization of es519xx_info structure 2013-10-13 14:54:54 +02:00
Uwe Hermann 93d719cde6 es519xx: Fix incorrect packet size, and a typo. 2013-10-07 00:36:18 +02:00
Uwe Hermann 72e1672fc9 es519xx: Cosmetics, coding style, minor fixes. 2013-10-07 00:36:18 +02:00
Aurelien Jacobs de737bfc11 add ISO-TECH IDM103N serial-dmm driver 2013-10-07 00:36:18 +02:00
Aurelien Jacobs c01bdebc57 add cyrustek es519xx generic protocol parser 2013-10-07 00:36:18 +02:00
Aurelien Jacobs 87532f23a4 output/analog: add revolutions per minute unit 2013-10-07 00:36:18 +02:00
Uwe Hermann 2f9376117c fx2lafw: Organize driver into api.c / protocol.[ch].
This now matches the naming conventions of the other drivers.
2013-10-06 22:28:45 +02:00
Daniel Thompson fbf07e0209 agilent-dmm: Fix SEGV during incomplete reply from meter.
If buf contains exactly the string "Agilent Technologies" (for example if
there are bugs in the timeout logic or serial driver causing the reply from
the meter to be abridged) then this code will SEGV. This is because tokens[1]
is NULL but only tokens[2] and tokens[3] (both of which are undefined) are
NULL checked.

Can be trivially corrected by NULL checking tokens[1] as well.

Signed-off-by: Daniel Thompson <daniel@redfelineninja.org.uk>
2013-10-04 13:30:49 +02:00
Daniel Thompson 5715e84fe3 serial: Only sleep when no characters are received.
g_usleep(XX) sleeps for *at least* XX microseconds but may sleep for
longers (on older kernels the sleep will typically be 10000us). Thus
byte receive loops containing an unconditional sleep will perform
very poorly (for example it causes the scan in agilent-dmm to timeout
prematurely).

Even on modern kernels serial_readline() has a 2ms sleep per byte which
means it will read at a maximum rate of half a character per millisecond
(~4800baud).

This is fixed by only sleeping when read() returns no data.

Signed-off-by: Daniel Thompson <daniel@redfelineninja.org.uk>
2013-09-26 14:57:37 +02:00
Uwe Hermann 1b142b7827 README.devices: Various updates and additions. 2013-09-25 14:26:36 +02:00
Uwe Hermann ba26f45d1d configure.ac: Don't build uni-t-ut32x if libusb-1.0 is not found. 2013-09-25 14:26:35 +02:00