Bert Vermeulen
0cd9107dfb
cem-dt-885x: Fix datalog on/off setting in max/min hold mode
...
As it turns out, the device randomly decides to send no logging state
info when max hold or min hold mode is enabled.
2013-06-17 16:17:39 +02:00
Bert Vermeulen
a90e480cdc
cem-dt-885x: Support for max/min hold modes
2013-06-17 16:17:39 +02:00
Bert Vermeulen
9fd6bc2054
Add SR_CONF keys for max/min hold modes
2013-06-17 16:17:39 +02:00
Bert Vermeulen
1487ce4fbc
cem-dt-885x: Support for changing time weighting
2013-06-17 16:17:39 +02:00
Bert Vermeulen
be73391982
cem-dt-885x: Support for changing frequency weighting
2013-06-17 16:17:39 +02:00
Bert Vermeulen
fd8854c4d0
Add SR_CONF keys for sound pressure level time and frequency weighting
2013-06-17 16:17:39 +02:00
Bert Vermeulen
e1af0e85b9
cem-dt-885x: Support for turning data logging on/off
2013-06-17 16:17:38 +02:00
Bert Vermeulen
3e62166ed3
Add SR_ERR_TIMEOUT
2013-06-17 16:17:38 +02:00
Florian Steinhardt
5f2a4aff4b
added Voltcraft M-3650D Multimeter
2013-06-14 01:03:29 +02:00
Bert Vermeulen
14cf708fef
cem-dt-885x: Send last measurement at normal rate in hold mode
...
The device only sends the "hold" token otherwise, which clashes somewhat
with other devices. This makes the device more predictable for frontends.
2013-06-12 18:34:42 +02:00
Bert Vermeulen
bc1143280f
cem-dt-885x: Hold off measurements in max/min hold mode
2013-06-12 18:34:42 +02:00
Bert Vermeulen
e37c4b3959
cem-dt-885x: Live SPL acquisition
2013-06-12 18:34:42 +02:00
Bert Vermeulen
7fb8279c9b
cem-dt-885x: Flesh out driver, add scan functionality
2013-06-12 18:34:42 +02:00
Bert Vermeulen
8fa9368eb4
cem-dt-885x: Initial driver skeleton.
2013-06-12 18:34:42 +02:00
Uwe Hermann
28083961fb
scanalogic2: Only print actual state changes in the log.
2013-06-11 18:39:55 +02:00
Uwe Hermann
9526f2d4f8
scanalogic2: Replace %i with %s where needed.
2013-06-11 18:39:54 +02:00
Uwe Hermann
79914b3a62
scanalogic2: Shorten a few function name prefixes.
...
The driver-private helper functions in protocol.c can have a shorter
prefix to make the code look nicer.
2013-06-11 18:39:54 +02:00
Uwe Hermann
c824eb6323
scanalogic2: Cosmetics, whitespace, typos, etc.
2013-06-11 18:39:54 +02:00
Marc Schink
e52e712d05
Initial driver for IKALOGIC Scanalogic-2
2013-06-11 18:39:54 +02:00
Marc Schink
16e76baec9
ikalogic-scanalogic2: Initial driver skeleton.
2013-06-11 18:39:54 +02:00
Uwe Hermann
eea49cf10d
ols/link-mso19: Consistency fixes.
...
Use the same setup/ordering/naming for the cleanup/dev_clear functions
as all other drivers do.
2013-06-02 17:03:40 +02:00
Uwe Hermann
1c2d542df2
demo: Use std_dev_clear().
2013-06-02 16:57:07 +02:00
Uwe Hermann
3b412e3a30
s/clear_instances/dev_clear/.
...
Consistently use the same name for the dev_clear() API callback
everywhere.
2013-06-02 16:56:41 +02:00
Uwe Hermann
f6beaac55c
std: Drop hw_ from function names.
...
The per-driver API calls no longer have a hw_ prefix (e.g. hw_init()
became init() and so on), so drop the 'hw_' from the std versions
for those API callbacks too.
2013-06-02 16:46:18 +02:00
Uwe Hermann
3678cf73fe
asix-sigma: Use std_dev_clear().
2013-06-02 16:46:18 +02:00
Uwe Hermann
c43cf4d40e
alsa: Use std_dev_clear().
2013-06-02 16:46:17 +02:00
Uwe Hermann
fa85f37630
rigol-ds1xx2: Use std_dev_clear().
2013-06-02 13:52:40 +02:00
Uwe Hermann
dec6c583a2
hantek-dso: Simplify cleanup().
2013-06-02 13:52:40 +02:00
Uwe Hermann
658636f1c9
nexus-osciprime: Use std_dev_clear().
2013-06-02 13:52:40 +02:00
Uwe Hermann
c9d622a420
lascar-el-usb: Use std_dev_clear().
2013-06-02 13:52:40 +02:00
Uwe Hermann
771bd216fa
fluke-dmm: Use std_dev_clear().
2013-06-02 13:52:39 +02:00
Uwe Hermann
732899f8cf
colead-slm: Use std_dev_clear().
2013-06-02 13:52:39 +02:00
Uwe Hermann
676c28a846
agilent-dmm: Use std_dev_clear().
2013-06-02 13:52:39 +02:00
Uwe Hermann
8d18d266f5
victor-dmm: Use std_dev_clear().
2013-06-02 13:52:39 +02:00
Uwe Hermann
40bbc64293
brymen-dmm: Use std_dev_clear().
2013-06-02 13:52:39 +02:00
Uwe Hermann
adf33ecce5
csv output: Fix incorrect ordering of the probes.
...
The comment for the CSV output module says probes are ordered e.g.
0,1,2,3, but the actual values were in the 3,2,1,0 order.
We're fixing this by making the order of the probe values 0,1,2,3 too
for now, but this will become a configurable option later on.
Thanks Patrick Servello <patrick.servello@gmail.com> for the patch.
2013-05-22 14:58:09 +02:00
Uwe Hermann
ee8ddd8f5a
Always link against the math library.
...
This fixes bug #115 .
2013-05-10 21:46:30 +02:00
Uwe Hermann
96ea73db23
session_driver: Fix return codes, cosmetics.
2013-05-10 20:37:50 +02:00
Uwe Hermann
6078d2c996
Use consistent API callback function names.
...
This now matches what the 'new-driver' tool generates.
2013-05-10 20:01:37 +02:00
Uwe Hermann
8111446ae0
zeroplus: Properly set inst_type to SR_INST_USB.
2013-05-10 19:16:25 +02:00
Uwe Hermann
d6445cb0da
zeroplus: Use std_dev_clear().
2013-05-10 19:06:47 +02:00
Uwe Hermann
8dca646ef9
uni-t-dmm: Use std_dev_clear().
2013-05-10 18:59:46 +02:00
Uwe Hermann
3f0513bac1
serial-dmm: Use std_dev_clear().
2013-05-10 18:53:42 +02:00
Uwe Hermann
9790079961
chronovu-la8: Use std_dev_clear().
2013-05-10 18:40:13 +02:00
Uwe Hermann
decfe89d4e
Drop some lines that are no longer needed.
2013-05-10 18:30:32 +02:00
Uwe Hermann
0bdb4f2e4a
tondaj-sl-814: Use std_dev_clear().
2013-05-10 17:56:53 +02:00
Uwe Hermann
25e7adada7
mic-985xx: Use std_dev_clear().
2013-05-10 17:54:53 +02:00
Uwe Hermann
2a052cc4d6
Use consistent naming for internal libtool helper libs.
...
This now also matches what the 'new-driver' tool generates.
2013-05-10 17:44:01 +02:00
Uwe Hermann
9e165e742f
Use consistent HW_ name prefixes everywhere.
...
Older drivers used LA_* previously, we now use HW_* everywhere though.
2013-05-10 17:18:42 +02:00
Uwe Hermann
576ff5b0ba
device.c: Add missing @since markers.
...
Also, add Doxygen comments for functions which don't have any yet.
2013-05-08 16:52:49 +02:00